Contact Us
  • Home
  • COMPONENTS
  • MEMS Accelerometers for Vibration and Tilt Measurement

MEMS Accelerometers for Vibration and Tilt Measurement

Three axis MEMS accelerometers with digital or analog output and ranges from 2 g to 50 g. Noise density from 22.5 microgram per root hertz on the 20 bit ADXL355. Supply current from 1.8 microamp at 100 Hz on the ADXL362. LCC, LGA and QFN packages, with SPI or I2C output and embedded FIFO.
quote now

Product Specifications

Product Overview

An accelerometer for condition monitoring is bought on noise density, not on range. A bearing fault shows up as a small signal at a few kilohertz, and a part with 550 microgram per root hertz of noise will bury it long before the range is reached. The same is true of tilt: one degree of tilt is 17 mg, so a part with 10 mg of offset drift over temperature cannot hold a levelling loop, no matter how many bits the ADC has.

The low noise end of this page is the ADXL355, a 20 bit part with 22.5 microgram per root hertz, 0.15 mg per C of offset drift and 200 microamp in measurement mode, in a hermetic 6 by 5.6 mm LCC. Its analogue twin, the ADXL354, brings the same sensing element to a 14 bit external converter through a 1.8 V analogue output with a user set bandwidth. Both have programmable high pass and low pass filters and an interpolation routine for synchronous sampling, which is what a seismic or structural node needs to keep several channels in phase.

The micropower end is the ADXL362, which samples the full bandwidth at 1.8 microamp at 100 Hz instead of duty cycling, with 270 nA in motion triggered wake up and 10 nA in standby, so a wireless sensor can sleep until something moves. The LIS2DW12 covers the middle ground with 90 microamp in high performance mode, 0.38 microamp in the lowest power mode, 90 microgram per root hertz and a 32 level FIFO in a 2 by 2 mm LGA, which is the shape used on wearable and battery powered machine tags.

Key Specifications

ParameterLow noise and precisionMicropower and embedded
Range2 g, 4 g, 8 g selectable2 g to 16 g selectable, 2 g to 8 g on the ADXL362
Resolution20 bit on the ADXL355, 12 bit on the ADXL36216 bit on the LIS2DW12
Noise density22.5 microgram per root hertz90 to 550 microgram per root hertz
Zero g offset drift0.15 mg per C maximum0.5 to 0.6 mg per C typical
Supply current200 microamp measuring, 21 microamp standby0.38 to 90 microamp depending on mode
OutputSPI and I2C, or analogSPI and I2C, or SPI only
FilteringProgrammable high pass and low pass, 1 Hz to 1 kHzAnti alias filter at half or quarter of the data rate
PackageLCC-14, 6 by 5.6 by 2.2 mmLGA-12 2 by 2 mm, LGA-16 3 by 3 mm

Included Models and Order Codes

The table lists the order codes most often quoted for machine monitoring, tilt and motion sensing. State the range, the bandwidth, the noise floor, the supply current budget and whether the part has to run from a coin cell, and the order code is confirmed.

Part NumberRangeOutputNoiseCurrentPackage
ADXL355BEZ2 g, 4 g, 8 g20 bit SPI and I2C22.5 microgram per root hertz200 microamp measuring, 21 microamp standbyLCC-14, 6 by 5.6 mm
ADXL354BEZ2 g and 4 g, or 2 g and 8 gAnalog, 1.8 V output22.5 microgram per root hertz150 microamp measuring, 21 microamp standbyLCC-14, 6 by 5.6 mm
ADXL362BCCZ2 g, 4 g, 8 g12 bit SPI550 microgram per root hertz, 175 in low noise mode1.8 microamp at 100 Hz, 270 nA wake upLGA-16, 3 by 3.25 mm
ADXL345BCCZ2 g, 4 g, 8 g, 16 g13 bit SPI and I2CNot specified as a density figure40 microamp measuring, 0.1 microamp standbyLGA-14, 3 by 5 mm
LIS2DW12TR2 g, 4 g, 8 g, 16 g16 bit SPI and I2C90 microgram per root hertz in high performance mode90 microamp high performance, 0.38 microamp low powerLGA-12, 2 by 2 mm
LIS3DHTR2 g, 4 g, 8 g, 16 g16 bit SPI and I2CNot specified as a density figure2 to 11 microamp low power, 185 microamp normalLGA-16, 3 by 3 mm
MMA8452QR12 g, 4 g, 8 g12 bit I2C99 microgram per root hertz6 to 165 microamp depending on modeQFN-16, 3 by 3 mm
ADXL1002BCPZ50 g single axisAnalog, 5 V supply25 microgram per root hertz1 mA, 21 kHz bandwidthLFCSP-32, 5 by 5 mm

Key Features

Noise stated as a density – a microgram per root hertz figure can be compared across parts and against the signal a bearing fault actually produces, which a resolution in bits cannot.

Offset drift over temperature – 0.15 mg per C is what allows a tilt sensor to hold a level without a periodic re-zero, and it is quoted per axis.

Micropower without aliasing – the ADXL362 samples the full band at every data rate instead of duty cycling, so a 1 kHz event is not folded down into a slow reading.

FIFO and interrupts – a 32 level FIFO and threshold interrupts let the host sleep while the sensor watches for a change, which is most of the power budget in a wireless node.

Self test – an electrostatic force moves the proof mass on command, so the signal chain can be verified in the fixture without a shaker.

Hermetic and plastic options – a hermetic LCC holds offset over years in a structural monitor, while a 2 mm plastic LGA is what fits inside a wearable.

Applications

These sensors are quoted for equipment that has to measure motion rather than detect it, typically where: A sensor node is normally quoted with the SUPERB PCB and SUPERB PCBA work we support for the same assembly, so the accelerometer, the mounting and the shielding are handled together.

Machine and bearing monitoring – a 20 bit part with 22.5 microgram per root hertz resolves a bearing tone at a few kilohertz long before it becomes audible, and a hermetic package holds its offset between services.

Tilt and levelling – an antenna, a solar tracker or a survey instrument needs offset drift per degree C and a low pass filter that can be set below the servo bandwidth.

Wireless motion tags – a 1.8 microamp part with a wake up threshold runs for years on a coin cell and only reports when the machine starts.

Sourcing and Cross-Reference

Accelerometers are qualified against a mounting and a bandwidth, and both are easy to lose in a second source. A replacement with the same range but a different resonant frequency will read differently above 1 kHz, and a part with a wider bandwidth will integrate more noise into the same velocity band. We quote the noise density, the offset drift and the filter range beside the order code, so the comparison is made on the signal chain rather than on the pinout.

The mechanical side matters as much: the package has to be coupled to the frame with the right adhesive or stud, the axis has to line up with the measurement direction, and the part has to be placed away from a switching regulator that would couple into a 20 bit converter. We quote the sensor with the mounting hardware and the decoupling that the datasheet asks for, and where the board is assembled in volume the placement is agreed with the test fixture.

Where the sensor nodes are built in volume, SUPERB Assembly support covers the placement, the reflow profile and the inspection of the LCC and LGA packages.

Q: Can you supply a low noise accelerometer that replaces an obsolete part with the same footprint?

A: Yes. Send the range, the bandwidth, the noise floor and the supply budget, and the SUPERB Tech sales team will confirm the order code, the package and the nearest part that keeps the same output interface.

Why Buyers Source Accelerometers Through SUPERB

  1. Noise and drift on the quote: the density, the offset drift and the filter range are stated per line, so a replacement is compared on the signal it will produce.
  2. Package and mounting: the LCC or LGA footprint, the mounting hardware and the reflow profile are quoted together, which keeps the first build from being a mechanical experiment.
  3. Lifecycle supply: parts that a monitor was qualified around are held with date codes, so a fleet stays serviceable while an alternative is characterised.
  4. Board build: placement next to the converter, the shield can and the test fixture are agreed with the same team that supplies the parts.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Sensors and detectors, Six axis IMU sensors, Barometric pressure sensors, 16 bit SAR ADCs, Obsolete part cross reference.