Single, dual and three axis MEMS gyroscopes from 100 to 2000 degrees per second, with digital SPI or I2C output and a noise density figure for each part.
quote now

Product Specifications

MEMS gyroscopes for stabilization and attitude control

Product Overview

A gyroscope measures rate, not angle. The angle comes from integrating that rate, which means a small bias error becomes a growing drift: a bias of 1 degree per second is 60 degrees of error after one minute. That is why the first question about any part is not its resolution but its bias stability, and why the parts on this page are split between those specified for stabilization, where bias matters, and those specified for gesture and motion, where repeatability over a second matters more than drift over an hour.

Full scale sets the other half of the trade. A part at plus or minus 2000 degrees per second survives a tumble and is used in a handheld or a drone flight controller, but each count is coarse. A part at plus or minus 100 degrees per second resolves a slow platform motion finely and clips in a fast one. The L3GD20H offers three settings in one part, 245, 500 and 2000 degrees per second, with 8.75, 17.5 and 70 millidegrees per second per count, so the range can be chosen per product without a new board.

The third number is noise. Rate noise density is given in degrees per second per root hertz, and it sets the smallest motion that can be seen in a short window. The ADXRS290 quotes 0.004 degrees per second per root hertz with a plus or minus 100 degrees per second range, which is why it is used for camera and antenna stabilization rather than for game controllers. Filtering reduces the visible noise but adds lag, and lag in a stabilization loop is what turns a stable platform into an oscillating one.

Key Specifications

ParameterMotion and gestureStabilizationMulti axis with accelerometer
Full scale245, 500 and 2000 dps in one part100 dps, dual axis250 to 2000 dps, 16-bit
Sensitivity8.75, 17.5 and 70 mdps per count200 counts per dps131 counts per dps at 250 dps
Rate noise0.03 dps per root hertz at the wide setting0.004 dps per root hertz0.05 dps per root hertz
OutputSPI and I2CSPII2C, SPI on the 6000 version
Supply2.4 V to 3.6 V2.7 V to 5 V2.375 V to 3.46 V
Current6 mA in full operation6 mA3.9 mA with the accelerometer running
Bandwidthprogrammable low pass, 12.5 Hz to 400 Hzprogrammable high pass and low passup to 1 kHz sample rate
PackageLGA-16, 3 x 3 mm4.5 x 5.8 mm cavityQFN-24, 4 x 4 mm

Included Models and Order Codes

The order codes below are the gyroscopes quoted most often for flight controllers, antenna and camera stabilization, industrial tilt sensing and handheld instruments. State the full scale, the axes, the interface, the supply and the loop rate, and the part and its filtering are confirmed together.

Part NumberAxesFull ScaleNoise or SensitivityInterfacePackage
L3GD20H3245, 500, 2000 dps8.75 to 70 mdps per countSPI, I2CLGA-16
ITG-320032000 dps14.375 counts per dpsI2C at 400 kHzQFN-24
MPU-60503 plus 3 axis accelerometer250, 500, 1000, 2000 dps131 counts per dps at 250 dpsI2C at 400 kHzQFN-24
MPU-60003 plus 3 axis accelerometer250, 500, 1000, 2000 dps131 counts per dps at 250 dpsSPI and I2CQFN-24
ADXRS2902, pitch and roll100 dps0.004 dps per root hertz, 200 counts per dpsSPI4.5 x 5.8 mm cavity
ADIS161361, yaw or roll450 dpsbias stability quoted by the makerSPImodule with a mounting frame

Key Features

Range set per product – the L3GD20H and the MPU-6050 keep three or four full scale settings in one part, so a fast tumble and a slow pointing motion can share the same board and the same footprint.

Noise stated as density – rate noise is given in dps per root hertz rather than as a peak to peak figure, because that is the number that goes into a loop filter calculation.

Bias and drift separated – parts for stabilization are listed with their bias figures, and parts for gesture sensing are not, because a drift of a few degrees per hour is irrelevant to a one second gesture.

Digital output with no analog front end – each axis has its own converter inside the package, so three channels arrive on one bus without a multiplexer, a reference or a matched filter chain.

Programmable filtering – the low pass corner is set in a register, which lets the same part serve a 400 Hz control loop and a 12.5 Hz tilt measurement without a component change.

Supply and logic separated – the MPU-6000 and the L3GD20H take a separate logic supply, so a 3.3 V sensor can sit on a 1.8 V bus without a level shifter.

Shock and vibration stated – the parts quote a shock rating in g for a short duration, which is what a handheld instrument or a drone frame is checked against.

Self test on the die – an internal excitation moves the proof mass electrically, so a production test can confirm that the sense path is alive without a rate table.

Applications

These parts are quoted for equipment that has to know how fast it is turning, typically where: The sensor is placed on the control board next to its decoupling and its mounting holes, so it is quoted with the SUPERB PCB and the SUPERB PCBA build for that board.

Flight control and gimbals – a 2000 dps part covers a flip in a drone, and a 100 dps part with low noise covers the slow correction of a camera gimbal, so both appear on the same bill of materials in different places.

Antenna and line of sight stabilization – a platform that has to hold a pointing angle needs a bias that does not walk, which is why the low noise dual axis part is used with a two axis frame rather than a single package with three axes.

Industrial tilt and platform levelling – a machine that levels itself integrates a rate over a fraction of a second, and the wide range part with a programmable filter keeps the loop stable while the chassis vibrates.

Handheld instruments and wearables – a three axis part with an accelerometer in the same package gives orientation without a second device, and the 3.9 mA figure fits a battery powered logger that samples in bursts.

Sourcing and Cross-Reference

Gyroscopes leave production quietly. Several motion parts that were standard for a decade are now marked as not recommended for new builds, while the module level parts for stabilization stay in production for much longer. A replacement has to hold the full scale, the axes, the interface and the register map, because a change in the register map is a firmware change, not a part change.

The mechanical side is often the harder half. A cavity package with a specific height and a specific mounting frame cannot be replaced by a leadless package without a board change, and the vibration coupling of the new part is different even when the electrical specification matches. For a stabilization loop that was tuned around one sensor, the loop constants usually need a check after any substitution.

Availability is the third factor. Motion sensors move between wafer fabs, and a part that shows stock today can be on a twelve week lead next quarter. The quotation line therefore states the batch date and the quantity behind it, and for a long life instrument the part is bought against a forecast rather than against a single order.

For volume builds, SUPERB Assembly support covers the stencil aperture, the paste volume and the reflow profile that cavity packages need to keep the die free of flux.

Q: Can you supply a gyroscope that keeps the same register map when the original part is discontinued?

A: Yes. Send the current part number, the full scale, the axes, the interface and the register map version, and the SUPERB Tech sales team will confirm the order code and the nearest part that keeps the footprint and the bus behaviour.

Why Buyers Source Gyroscopes Through SUPERB

  1. Range and axes matched: the substitute is chosen by full scale and axis count first, because a 2000 dps part and a 100 dps part are not interchangeable even when both are three axis devices.
  2. Firmware cost counted: the register map and the interface are checked before a part is offered, so a replacement does not arrive with a driver rewrite attached.
  3. Package and mounting checked: the cavity height and the mounting frame are part of the comparison, since a stabilization loop is tuned around the mechanical coupling of one package.
  4. Lifecycle tracked: motion parts under a not recommended notice are flagged with the equivalent that keeps the bus and the footprint, before a product line is caught without a sensor.