TPS563203DRLR
Product Specifications
TPS563203DRLR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS563203DRLR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS563203DRLR: 3 A synchronous buck, 4.2 V to 17 V input, 600 kHz, Eco-mode, SOT-563
TPS563203DRLR is a 3 A synchronous step-down converter with both switches inside a 1.6 mm by 1.6 mm six pin body, running at a fixed 600 kHz from a 4.2 V to 17 V input in a SOT-563 body of 6 pins. The two switches measure 100 milliohm on the high side and 55 milliohm on the low side at 25 degrees, which is low enough that the small body carries 3 A on a real board area. Control is D-CAP3, so there is no compensation network to fit and no COMP pin, and the part starts into a prebiased output without pulling the rail down. In Eco-mode the converter skips pulses at light load, which is why the no load current stays at 110 microamp instead of climbing.
Order code and package
| TPS563203DRLR | Active, SOT-5X3 (DRL) body, 6 pins, 4000 pieces on a large reel, Sn finish, marking T203 |
| TPS563203DRLR.A | Active, the same body and the same 4000 piece reel, with the material row printed at MSL Level-1-260C-UNLIM |
| TPS563206DRLR | Active, the same silicon in forced continuous conduction mode, same body, same 4000 piece reel, marking T206 |
| TPS562203DRLR | Active, the 2 A member of the family in the same six pin body, marking 2203 |
| Temperature range | minus 40 to 125 degrees junction on every published row |
Electrical parameters that decide the application
| Input voltage | 4.2 V to 17 V |
| Output voltage | 0.6 V to 7 V, set by a divider into the FB pin |
| Output current | 3 A continuous, with both switches integrated |
| Switch resistance | 100 milliohm high side, 55 milliohm low side at 25 degrees |
| Switching frequency | 600 kHz fixed, 100 ns minimum off time, 55 ns minimum on time |
| Feedback voltage | 600 mV nominal, 588 to 612 mV over minus 40 to 125 degrees |
| Valley current limit | 3.0 A minimum, 3.9 A typical, 4.8 A maximum |
| Quiescent and shutdown | 110 microamp no load in Eco-mode, 7 microamp with EN low |
Family variants and how they differ
| TPS563203 | Eco-mode at light load, the string on this page |
| TPS563206 | forced continuous conduction at light load, same 3 A rating and same body |
| TPS562203 | the 2 A member, same switch resistances and same 600 kHz |
| Soft start | 1.4 ms fixed, no external capacitor needed |
| Maximum duty cycle | about 95 per cent, which sets the input floor for a given output |
Points to check before this part goes on a BOM
Four point two volts is the input floor, and it is higher than a logic rail. The undervoltage lockout wakes the part between 3.6 V and 4.0 V and shuts it down between 3.2 V and 3.4 V, with 400 mV of hysteresis. A 5 V rail at minus ten per cent sits at 4.5 V and is inside the range. A 3.3 V rail is not, so this part cannot post regulate a 3.3 V bus, and a board that tries it will simply never start.
Seventeen volts is a twelve volt bus with margin, not a twenty four volt bus. A 12 V rail at plus ten per cent reaches 13.2 V, and a transient on an industrial supply rarely goes above 16 V. A 24 V bus sits above the rating even before tolerance, and a vehicle rail with load dump is far outside it. Those boards need a converter with a 28 V or higher input, and this string should not be offered for them.
The current limit is a valley limit, so it sits above the 3 A rating. The comparator watches the low side switch current, not the load current, and the minimum published point is 3.0 A with a 3.9 A typical and a 4.8 A maximum. That means the part holds 3 A with ripple on top, and a load that steps to 4 A for a few milliseconds will not necessarily trip it. A hard short pulls the valley current to the limit and starts the hiccup cycle, which is the behaviour a fixture has to expect.
Two strings share one die and differ only in light load behaviour. TPS563203 skips pulses in Eco-mode, and TPS563206 keeps switching at 600 kHz at every load. At 3 A the two are effectively the same part. Below about 200 mA the Eco-mode version is more efficient and produces a lower frequency ripple, while the forced continuous version holds a clean 600 kHz spectrum that suits a rail feeding an analogue front end. Sourcing either one for the other changes the light load ripple, not the footprint.
No compensation pin means the output capacitor is the loop. D-CAP3 is stable with low ESR ceramic output capacitors across a wide range, but not across every value. A board that replaces a 22 microfarad capacitor with 220 microfarad to chase ripple changes the transient response and can ring on a load step. The capacitor range in the application section is the one to stay inside, and the effective value after bias derating is what counts, not the marked value.
The 1.4 ms soft start is fixed and it is short. It is enough to keep a moderate output capacitor from looking like a short at power up. It is not a sequencing tool. On a board with several rails the enable pin has to be driven by a supervisor or a sequencer, and the 1.21 V threshold with 1 microamp of pulldown is what the driving circuit has to work against.
The minimum on time caps how far down the output can go at high input. At 600 kHz and 55 ns, a 17 V input can only produce a very short pulse, so an output below roughly 0.6 V at the top of the input range is reached by skipping cycles rather than by clean regulation. A rail that has to sit at 0.6 V to 0.8 V from a 17 V bus is better served by a part with a higher switching frequency or a lower input.
The 1.6 mm body has almost no lead area, so the copper under it is the thermal path. From 12 V to 5 V at 3 A the conduction loss alone comes to about 0.66 W, split between the two switches by duty cycle, before any switching loss. That is a real number in a body this size. A board with a ground pour and several vias under the part carries it; a board with the part on a narrow trace folds back on thermal shutdown under a load it was rated for.
A prebiased output is handled, and that matters on a shared bus. The converter starts into a rail that is already charged without discharging it first, which is what happens when a 5 V standby rail holds the output up while the main converter is still off. A part without that feature pulls the rail down at start up and can reset the circuit that was being kept alive.
The marking is T203 and the reel carries 4000 pieces. Two active rows share that marking, one of them printed at MSL Level-1-260C-UNLIM, which means no bake clock and no floor life tracking on the line. A 4000 piece reel also means a prototype quantity of a few hundred pieces comes as a broken reel, and that has to be agreed before the order is placed rather than discovered at packing.
What to confirm before this part goes on a purchase order
State the input bus and the output voltage together with the part number. The same string is used on a 12 V to 5 V rail and on a 12 V to 3.3 V rail with a different divider, a different inductor and a different output capacitor, and a substitute offered without the bus voltage cannot be checked against ripple or thermal margin.
Ask which row ships, and ask for the date code and the country of origin on the offer. The base row and the .A row are functionally the same part but carry different moisture sensitivity statements, and a customer who filed a material declaration against one row and receives the other has a documentation problem even when the silicon is identical.
Where this order code fits
It makes a 5 V or 3.3 V rail at 3 A from a 12 V adapter in a set top box, a television main board or a building controller, where the switching spectrum has to stay inside the conducted emissions limit without a second filter stage. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.
Questions buyers ask
Can it run from a 5 V rail and produce 3.3 V? Yes. The input range starts at 4.2 V and a 5 V rail at minus ten per cent is 4.5 V, so the part regulates, but the duty cycle is 66 per cent and the dropout margin is thin at full load. A 3.3 V output from a 5 V bus is comfortable; a 3.3 V output from a 3.3 V bus is impossible.
Does it need an external compensation network? No. The loop is compensated inside the part, which is why there is no COMP pin. The output capacitor still has to be chosen inside the range the application section gives, and its effective value under bias is what the loop sees.
What happens during a shorted output? The valley current limit holds the inductor current at the set point, and if the output stays below the undervoltage threshold the part enters hiccup: it switches for a short window, stops for a longer one, and repeats. The output therefore pulses rather than sitting at zero, which a test fixture that expects a static reading will misread.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.