TPS48110AQDGXRQ1
Product Specifications
TPS48110AQDGXRQ1
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS48110AQDGXRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS48110AQDGXRQ1: the 100 V automotive high side driver without the precharge branch
TPS48110AQDGXRQ1 is the member of the TPS4811-Q1 family that drives external back-to-back N-channel MOSFETs from a 3.5 V to 80 V rail, with a 100 V absolute maximum, and does it without the precharge gate driver that the 48111 variant carries. It is an automotive grade part, AEC-Q100 qualified at temperature grade 1, and it sits in a 19-pin VSSOP with a pin removed between adjacent high voltage and low voltage pins to give 0.8 mm of clearance.
The reason a part like this exists is that a power distribution box in a vehicle is no longer a fuse and a relay. Loads switch on and off under software control, a short on one branch must not take down the bus, and the diagnostics have to say which branch failed. This device integrates the charge pump that makes an N-channel FET usable as a high side switch, the current sense that reports load current to an analogue input, a two-level overcurrent scheme with separate thresholds and timers, and a remote temperature sense that uses a diode in the FET package.
The numbers below come from SLUSEE5E, revised April 2026, and from the orderable addendum in the same document.
What the order code sits on
| Function | 100 V smart high side driver with protection and diagnostics |
| Input range | 3.5 V to 80 V operating, 100 V absolute maximum |
| Reverse polarity | protected down to minus 30 V |
| Gate drive | 3.7 A peak source, 4 A peak sink, external N-channel FETs |
| Charge pump | integrated 12 V, 100 microamp capacity |
| Shutdown current | 1.6 microamps at 48 V with EN/UVLO low |
| Current monitor | analogue IMON output, 2 percent accuracy at 30 mV sense |
| Overcurrent | two levels, IWRN and ISCP, with an adjustable circuit breaker timer |
| Short circuit response | 4 microseconds on this variant, 1.2 microseconds on the 48111 |
| Fault flags | FLT_I for current, FLT_T for temperature |
| Undervoltage and overvoltage | adjustable with better than 2 percent accuracy |
| Temperature sense | remote diode input, overtemperature protection with flag |
| Qualification | AEC-Q100 grade 1, minus 40 to plus 125 degrees ambient |
| Package | VSSOP DGX, 19 pins, 5.10 mm by 3.00 mm |
| Reel | 5000 pieces on a large reel, moisture level 2 |
Two current thresholds, and why both are needed
A single current limit cannot serve a load that has a normal inrush and an abnormal short. The warning threshold, IWRN, is set to the highest current the load legitimately draws, and the short circuit threshold, ISCP, is set well above it. When the current crosses the warning level the device starts the circuit breaker timer, which is adjusted by the TMR pin, and if the current stays above the threshold for the whole timer period the FET is switched off and the fault flag is asserted. If the current instead jumps straight past the short circuit threshold, the device acts within microseconds and does not wait for the timer.
The timer is what makes the scheme usable with capacitive loads. A module with a large input capacitance draws a current spike at switch-on that would trip any fixed limit, and the timer gives that spike a defined window in which to decay. The value of the capacitor on TMR sets the window, so a rail with a bigger capacitance gets a longer timer, and the same board can serve two loads with different inrush by changing one component.
Auto retry and latch off are both configurable, and the choice matters more than it looks. Auto retry keeps a load alive through a transient but can turn a persistent short into a thermal cycle that eventually destroys the FET. Latch off protects the FET and requires a controller to clear the fault, which is the usual choice when the load is expensive and the controller is already watching the flag.
The current monitor and what its accuracy means in practice
The IMON output is an analogue voltage proportional to the voltage across the sense resistor, and the accuracy is specified as 2 percent at 30 mV of sense voltage. That qualifier is doing real work: at 30 mV the amplifier offset is a small fraction of the signal, while at 3 mV the same offset is ten times larger relative to the reading. A system that uses IMON to estimate load current over a ten to one range should expect the error to grow at the bottom of the range, and a system that uses it only to detect an open load or a gross overcurrent is unaffected.
The sense resistor itself is usually the dominant error. A 1 milliohm shunt at 20 A drops 20 mV and dissipates 0.4 W, which is a real thermal problem in a distribution box, while a 0.5 milliohm shunt halves the loss and halves the signal. The 2 percent figure applies to the amplifier, not to the combination, and the temperature drift of the shunt adds a term that is not in the data sheet at all.
Back-to-back FETs are the other half of the circuit. The device drives a common source pair so that the body diode of one FET blocks reverse current while the other carries the load, which is what gives the minus 30 V reverse polarity rating. The gate drive has to charge both gates, and the peak current figures are what determine how fast the pair turns on. A pair with a large total gate charge will turn on more slowly than the short circuit response time, and the safe operating area of the FETs has to cover the interval.
Thermal sensing through a diode
The remote diode input measures the temperature of a sensor inside the FET package rather than the temperature of the controller. That is the right place to measure, because the FET is where the loss is, and the controller can be several centimetres away on a board where the copper spreads heat unevenly. The device compares the diode reading against its own thresholds and asserts FLT_T when the limit is crossed.
The consequence for the board is that the FET package has to have a diode brought out, and not every MOSFET does. A customer replacing a competitor part often finds that the chosen FET lacks the sense diode, and the protection scheme then has to fall back to the controller's own junction temperature, which responds slowly and sits in the wrong place.
Carriers and what the addendum prints
| TPS48110AQDGXRQ1 | VSSOP DGX, 19 pins, 5000 pieces on a large reel, active |
| Lead finish | NIPDAU |
| Moisture level | Level-2-260C-1 YEAR |
| Operating temperature | minus 40 to plus 125 degrees |
| Sibling string | TPS48111LQDGXRQ1, same body and reel, with the precharge driver |
| Package quantity | 5000 per reel, unusual for a 19-pin body and worth noting on the order |
| Clearance | 0.8 mm between adjacent high voltage and low voltage pins |
The 5000 piece reel is the line to check on a purchase order. Nineteen-pin analogue bodies usually ship 2500 or 3000 to a reel, and a planner who assumes the smaller figure will under-order by a factor of two. It also means a small build is buying a partial reel, and the cut has to be taped and labelled to keep the moisture record intact.
Where a 100 V driver belongs in a vehicle
The obvious socket is the power distribution box, where a handful of these devices replace the relay and fuse array behind the body controller. The less obvious one is the battery management system, where the same part isolates a pack string and reports the current through it, and the DC/DC input, where it provides reverse polarity protection and a controlled start into a large input capacitance. The 48111 variant exists for exactly that last case, because the precharge branch charges the capacitance through a resistor before the main FET closes.
A 48 V mild hybrid bus is inside the 80 V operating window with margin for load dump only if the front end clamps, since the 100 V absolute maximum is not a load dump rating. The circuit around the device has to handle the transient, and the board has to keep the clearance the package was built to provide. When a customer brings a distribution board for assembly, the parts on it usually include a mix of devices in this class, and the substitution question is about the gate drive strength and the fault flag logic rather than the headline voltage. Our power management cross reference page lists the rows to compare, and the BOM shortage recovery page covers the case where the original device is quoted beyond the build date.
Questions buyers ask before a first order
Does this variant precharge a capacitive load? No. The precharge driver and its control input belong to the 48111 string. On this part the main FET closes directly, and the inrush has to be handled by the FET safe operating area and the circuit breaker timer.
Can the current monitor drive an ADC directly? It can, provided the ADC input range covers the IMON span and the reading is taken after the amplifier has settled. The output is a low impedance analogue node, so a series resistor and a capacitor at the ADC pin are still good practice.
What clears a latched fault? A cycle on the enable input, in the configuration where latch off is selected. The flag stays asserted until the fault is cleared, which is what allows a controller to log the cause rather than see a transient.
Is the part qualified for a 12 V system with load dump? AEC-Q100 grade 1 covers the temperature and the qualification tests, but the 100 V absolute maximum is below a load dump pulse. The front end protection has to be sized for the vehicle specification, and the device survives what reaches it after that clamp.