Contact Us

TPS3420DDRYR

Brand: Texas Instruments
Texas Instruments TPS3420DDRYR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS3420DDRYR — Power Management & Signal Chain | Superb Automation

TPS3420DDRYR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS3420DDRYR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS3420DDRYR dual push button controller with a 7.5 s hold time

The TPS3420DDRYR turns two push buttons into a reset signal without a processor pin and without a debounce capacitor. Both inputs have to be held low for the selected hold time before the reset output goes active, and the output stays active until one of the buttons is released. The hold time comes from the TS pin, 7.5 s typical when TS is tied to ground, which is long enough that a pocket press does nothing and short enough that a user does not think the product has frozen.

The family has three members and they behave differently at the output. The TPS3420 latches the reset until a button is released. The TPS3421 releases the reset after a fixed 400 ms pulse once the hold time expires. The TPS3422 watches a single input and also gives a fixed pulse. All three run from 1.6 V to 6.5 V and draw 250 nanoamp typical, which is what makes them usable on a product that sits in standby for months.

Key parameters taken from the TPS342x document

Supply range1.6 V to 6.5 V
InputsTwo push button inputs on this member, both must be low for the hold time
Hold time6 s minimum, 7.5 s typical, 9 s maximum with TS tied to ground
Second timing optionA shorter option is available on the E and G suffixes, 10 s to 12.5 s on the TS to ground setting, and the TS to supply setting is for factory test only
OutputOpen drain active low RST, which can be wire-ORed with other reset sources
Output behaviourOn this member RST stays low until one of the button inputs is released, unlike the pulse members
Supply current250 nanoamp typical, which is the whole reason the part exists in battery products
Detection delay150 microseconds typical from the input edge to the output, for the zero second condition
Start-up delay300 microseconds typical after the supply rises, which keeps a power-on edge from looking like a press
Input pull upInternal, so the buttons only have to pull to ground
TemperatureMinus 40 C to 125 C junction
PackageUSON-6, 1.45 mm by 1.00 mm, 5000 pieces on a large reel or 250 on a small reel, moisture level 1, marking AD

The two timing families inside one datasheet are easy to mix up. The plain D suffix gives the 7.5 s hold, the E and G suffixes give the longer or shorter options, and the TS to supply setting gives a zero second delay that the vendor marks as a factory test condition rather than a product setting.

Where the numbers matter in a real build

The hold time is a product decision, not an electrical one. Seven and a half seconds is long enough that a user who wants a reset will press and wait, and short enough that a support call does not start with a description of a frozen screen. A two button arrangement, where both have to be pressed, is what makes an accidental reset in a bag almost impossible, and it also means the product does not need a recessed reset hole in the enclosure.

The second number is the 250 nanoamp supply current. On a product that sits in a drawer for a year, this part adds almost nothing to the drain, and that is why it can be tied to the always-on rail rather than to a switched one. A part that drew 50 microamp would need its own load switch, which costs more than the controller.

The third is the open drain output. RST needs a pull up to the processor rail, and the pull up has to be present even when the processor is in its lowest power state, otherwise the button does nothing. That pull up is also the path by which the controller can hold a processor in reset while the rest of the board is powered down.

What to check before a purchase order is released

  • The hold time option, since the D, E and G suffixes give different windows and the letter is easy to lose on a purchase order.
  • The output behaviour, because the latch and pulse members are not interchangeable in the software.
  • The pull up on RST, without which the open drain output never releases the processor.
  • Whether one button or two are needed, since the single input member is a different part number.
  • The 300 microsecond start-up delay against a supply that ramps slowly, because a slow ramp is not the same as a press.
  • The reel size, because the small reel carries 250 pieces and a production run usually needs the 5000 piece reel.

Which projects this part fits

The vendor lists smart phones, tablets and ultrabooks, gaming consoles, portable consumer products, navigation devices, consumer medical products and toys. The pattern is a sealed product with a membrane or capacitive button and no room for a mechanical reset switch, where the reset has to be deliberate and the standby current has to be almost zero.

Questions that come up before a purchase order is released

Can the hold time be changed without a new part?

No. The hold time is set at the factory and selected by the suffix and the TS pin. A product that needs a different hold time needs a different order code.

Does a short press do anything?

No. A press shorter than the hold time is ignored, which is the point of the long timer. The processor does not see an interrupt from this part at all.

What holds the reset after the button is released?

Nothing on this member. RST is released when a button is released, so the processor starts as soon as the user lets go. The pulse members behave differently.

Is the part suitable for a 12 V product?

No. The supply range stops at 6.5 V, so a 12 V product needs a local rail or a different device.

How SUPERB handles this line

Push button controllers sit on boards that also carry the connector, the ESD array and the power switch, so they are usually bought as a group rather than on their own. Our power management cross reference lists the members of this family beside the parts they replace, and our one stop BOM sourcing covers a build where the small parts are the ones that delay the line. Where the original suffix is no longer available, the drop in replacement check is the list we work through before quoting a substitute.