TPS24700DGK
Product Specifications
TPS24700DGK
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS24700DGK from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS24700DGK 2.5 V to 18 V hot swap controller with a latch on fault, driving an external MOSFET
The TPS24700 is a hot swap controller for rails between 2.5 V and 18 V that drives an external N channel MOSFET and protects the supply from an overload. It has two thresholds rather than one: a current limit at 25 mV across the sense resistor and a fast trip at 60 mV. The gap between them is the number that decides whether a brief overload is ridden out or cut off, and the latch member holds the MOSFET off once the fault timer expires.
The part carries a power good output, an enable input with a defined threshold, a fault timer programmed by a capacitor, and an over temperature shutdown at 140 C. Its own document notes that it replaces the LTC4211 in existing boards with no printed circuit board changes and only minor external component changes, which is the reason a number of telecom and server platforms still carry it in their bills of materials.
Key parameters taken from the TPS24700DGK document
| Input range | 2.5 V to 18 V recommended operating on the sense and supply pins |
| Current limit threshold | 25 mV typical across the sense resistor, with a 22.5 to 27.5 mV window |
| Fast trip threshold | 60 mV typical with a 52 to 68 mV window, which is the severe overload and dead short path |
| Fast turn off | The gate is pulled down within 8 to 18 microsecond of the fast trip threshold being crossed |
| Fast turn off delay | 200 ns from an 80 mV step across the sense element |
| Supply current | 1.4 mA maximum with the part enabled, summed across the output, supply and sense pins |
| UVLO | 2.32 V rising with a 2.2 to 2.45 V window and 2.22 V falling, 0.1 V of hysteresis |
| Enable threshold | 1.3 V typical falling, 1.2 to 1.4 V window |
| Fault timer | A capacitor on TIMER, with a lower threshold of 0.35 V and a bleed down resistance to reset between events |
| Over temperature | 140 C rising with 10 C of hysteresis, which is the last line of protection |
| Gate drive | Charge pump output that holds the gate above the rail so an N channel MOSFET can sit in the high side |
| Power good | Open drain output, PGb, which pulls low while the output is out of range |
| Package | VSSOP DGK, 8 pins, 80 pieces in a tube and 2500 pieces on a large reel |
| Moisture and temperature | Level 1 at 260 C with unlimited floor life, minus 40 to 85 C |
| Addendum status | TPS24700DGK and TPS24700DGKR are Active and in Production, marking 24700 on the tube rows and 24701 on the reel row |
Every row above is read from the vendor document, not from a distributor summary. Where a window is printed, the window is what a production test should use, and the typical value is only a starting point for a first article.
Where the numbers matter in a real build
The two thresholds are the reason this part is easier to tune than a single limit controller. A load that draws 30 percent above its rating sits between 25 mV and 60 mV, so the part regulates the current and starts the fault timer. A dead short crosses 60 mV within microseconds and the fast path turns the gate off before the MOSFET can be damaged. Setting the sense resistor for the 25 mV limit therefore also sets the fast trip point at 2.4 times that current, and that ratio is fixed by the part.
Latch behaviour matters on a backplane. When the timer expires the MOSFET stays off and the only way back is to cycle the enable pin, which means a board that faulted has to be released by the controller or by a person. That is the correct behaviour for a shelf where a technician may be replacing a card, and it is the wrong behaviour for equipment on a pole, which is why the sibling part with the retry behaviour exists.
The gate drive and the sense element are where the external component choices show up. The sense resistor has to be a low inductance type with a tight tolerance, because 25 mV across 2 mOhm is 12.5 A and a 1 percent error on the resistor is 1 percent on the limit. The gate has to have a series resistor and a capacitor to ground in series, which the document specifies with the capacitor not directly to ground, and that combination sets the turn on ramp and the turn off speed.
The 200 ns fast turn off delay is the specification that protects the MOSFET. A short on the output of a 12 V rail through a few milliohm of trace can reach hundreds of amps in a microsecond, and only a comparator that acts inside that window keeps the FET inside its safe operating area. The 8 to 18 microsecond figure is the time for the gate to actually come down, so the current stops rising when the comparators act and then decays as the gate discharges.
The over temperature shutdown at 140 C is not an operating point. It is the last line for a fault that the timer did not catch, and a product whose normal operation brings the part anywhere near that temperature has a thermal problem the controller cannot solve. The relevant number for a normal build is the junction to ambient path of the external MOSFET, not the controller, because the controller dissipates only its own supply current.
- Sense resistor value and tolerance, since the same element sets both the 25 mV limit and the 60 mV fast trip point.
- Gate resistor and capacitor arrangement, which the document specifies as a capacitor in series with a resistor rather than a capacitor to ground.
- Fault timer capacitor against the transient the product has to ride out, not against the steady state load.
- Enable pin state during power up, because a floating pin can hold the rail off or turn it on at the wrong time.
- Power good polarity, which is open drain and pulls low, against the logic of whatever consumes the signal.
- Junction temperature of the external MOSFET at the current limit, which is the device that dissipates during a fault.
Which projects this part fits
This part fits 12 V and 5 V hot swap in servers, storage shelves, telecom line cards, industrial backplanes and test equipment with pluggable modules. It also fits products that were built around the LTC4211 and need a second source without changing the board, because the document states that the TPS24700 and TPS24701 replace that part with no board changes and only minor external component changes.
Questions that come up before a purchase order is released
What is the difference between the current limit and the fast trip?
The current limit at 25 mV regulates the current and starts the fault timer, which allows a transient to pass. The fast trip at 60 mV turns the gate off within microseconds, which is the dead short path. The ratio between them is fixed by the part at about 2.4 to 1.
Why does the reel row carry a different marking?
The addendum prints marking 24700 on the tube rows and 24701 on the 2500 piece reel row of TPS24700DGKR. A production line that verifies marking against the orderable string should know that the two differ, and a purchase order should name the carrier as well as the part number.
Can the part be used at 24 V?
No. The recommended operating range stops at 18 V, and the absolute maximum is only slightly above it. A 24 V rail needs the higher voltage member of the family, which is a different part with a different sense threshold.
What sets the fault time?
The capacitor on the TIMER pin. The part bleeds that capacitor down between events, and the lower threshold of 0.35 V is the point at which the timer resets, so a capacitor that is too small will reset before the load has finished charging.
Does it need a separate bias supply?
No. The part runs from the rail it protects and generates the gate drive above the rail with an internal charge pump, so an N channel MOSFET can be used in the high side position.
What happens after a fault?
On this member the MOSFET stays off after the timer expires. The enable pin has to be cycled before the rail comes back, which is the behaviour a backplane wants and the reason to choose the sibling part for unattended equipment.
How SUPERB handles this line
We supply the TPS24700DGK as 80 piece tubes and the DGKR on 2500 piece reels, with the date code and marking recorded. The power management cross reference page lists the hot swap controllers we carry by voltage and by sense threshold, pin to pin cross reference covers the LTC4211 second source case, and last time buy and LTB planning is how we handle a platform that is still shipping on a part the vendor has moved to a legacy status.