Contact Us

TPS2421-1DDAR

Brand: Texas Instruments
Texas Instruments TPS2421-1DDAR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS2421-1DDAR — Power Management & Signal Chain | Superb Automation

TPS2421-1DDAR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS2421-1DDAR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS2421-1DDAR: 5 A 20 V hot swap controller with the pass FET inside an eight pin SO PowerPAD

TPS2421-1DDAR is a complete hot swap front end with an integrated N channel pass MOSFET, a programmable fault current, a separate higher current limit and a fault timer in a SO PowerPAD (DDA) body of 8 pins. It protects a bus up to 20 V and passes 5 A continuously through an internal FET with 33 milliohm typical and 50 milliohm maximum on resistance. The fault current is set by one resistor to ground, the hard current limit sits at about 150 percent of that value, and a capacitor on the CT pin sets how long the load may stay above the fault threshold before the device latches off.

Order code and package

Order code read outTPS2421-1 DDA R: controller TPS2421 with latch off on fault, DDA eight pin SO PowerPAD, R large tape and reel
PackageSO PowerPAD (DDA), 8 pins, 4.89 mm by 3.90 mm, exposed pad on the underside
Carrier in the vendor addendumTPS2421-1DDAR at 2500 pieces on a large reel; TPS2421-1DDA is the same part in a 75 piece tube
Moisture levelLevel 2, 260 degrees peak reflow, one year floor life
Lead finishNickel palladium gold, quoted as NIPDAU
Temperature gradeJunction minus 40 to plus 125 degrees, storage minus 65 to plus 150
Absolute maximum25 V on VIN and VOUT, 6 V on EN, 20 V on FLT and PG, 9 A continuous output current, junction internally limited

Electrical parameters that decide the application

Input range3 V to 20 V recommended, with turn on guaranteed by a maximum undervoltage threshold of 2.9 V
Continuous current5 A, against a 9 A absolute maximum and a 3 to 7.5 W internal power limit that protects the FET
On resistance33 milliohm typical and 50 milliohm maximum at 1 A to 4.5 A, so 5 A produces about 1.25 W in the pass device
Fault current0.8 to 1.2 A with a 200 kohm resistor, 1.8 to 2.2 A with 100 kohm and 3.6 to 4.4 A with 49.9 kohm
Hard current limitAbout 1.5 times the fault current, with a 1.1 to 2.1 ratio window, so a 49.9 kohm setting limits at 2.3 to 5.5 A
Power limiting3 W minimum, 5 W typical and 7.5 W maximum, which is the safe operating area guard for the internal FET
Fault timerA capacitor on CT sets the time; the timer charges at 1.4 microamp typical and the upper threshold is 1.4 V typical
Power goodPG pulls low when the input to output difference falls below 0.4 to 0.75 V, with 0.1 to 0.4 V of hysteresis
Bias current25 microamp typical and 100 microamp maximum enabled, 3.9 to 5 mA in the disabled state
Reverse behaviourA body diode drop of 0.77 to 1 V appears when the output is driven above the input, and the part does not block reverse current
Thermal shutdown160 degrees junction with 10 degrees of hysteresis
EnableEN is active low with a 0.8 to 1.5 V threshold and 150 mV of hysteresis, so it can be driven from a 3.3 V logic pin

The two thresholds and the two family members

TPS2421-1DDARthe latch off version, which stays off after a fault until the enable pin is cycled
TPS2421-2the same silicon with automatic retry, chosen where an unattended card should come back on its own
Fault currentthe lower threshold that starts the timer, set by RISET between 49.9 kohm and 200 kohm
Hard current limitthe higher threshold, about 150 percent of the fault current, that acts immediately
Timer capacitorsets the window between the two, which is how a disk drive or a card with a large input capacitor is allowed to start

Points to check before this part goes on a BOM

The two current thresholds are the whole point of this device. A load such as a disk drive or a plug in card draws a burst of current at start up that is well above its steady state, and a single limit set for that burst would be useless as protection. The fault threshold is set to the load's real current, the timer allows a brief excursion above it, and the hard limit at about 150 percent catches a genuine short before the timer has a chance to matter. Setting the resistor for the inrush rather than the steady state current throws that structure away.

The internal FET is protected by a power limit rather than by the current limit alone. Between 3 W and 7.5 W the part folds the current back so the device stays inside its safe operating area, which is what allows a 20 V hot swap in an eight pin body without an external sense resistor or an external FET. The consequence is that a short on a 12 V bus does not produce 5 A: it produces whatever current keeps the dissipation at the power limit, and the timer then decides how long that continues.

The 50 milliohm maximum on resistance is the number to use in a thermal calculation. At 5 A it is 1.25 W in an SO PowerPAD with a junction to ambient figure of 41.3 degrees per watt on a good board, which is a 52 degree rise. In a 70 degree enclosure that is already at the edge of the 125 degree junction rating before any fault occurs, so a 5 A continuous load needs copper under the pad and often airflow, and a 3 A load is a much easier build.

The latch off and retry versions solve different problems. A line card that has failed should stay down so the operator knows which card to replace, which is the TPS2421-1. A fan tray or an inaccessible module in a sealed enclosure is better served by the retry version, which keeps trying and recovers when the fault clears. The two are separate order codes and the difference is inside the device, so the choice has to be made on the purchase order rather than at the assembly stage.

The power good comparator looks at the difference between input and output, not at an absolute level, so it releases when the pass FET is fully enhanced. A card that feeds a downstream converter should use PG to hold that converter off until the hot swap has finished charging the input capacitance, which is the reason the pin exists. The threshold of 0.4 to 0.75 V is wide, and a board that needs a precise handover point should add its own comparator.

There is no reverse current blocking. If the output is held above the input by another source, current flows back through the body diode with a 0.77 to 1 V drop, and the device does not report a fault. In a redundant supply arrangement where one card can be live while the other is inserted, that path has to be handled outside the part, usually with a second device or an ideal diode, and the reverse current is a real thermal load rather than a datasheet curiosity.

Where this order code fits

Used on RAID controllers, telecom line cards, solid state drive carriers, PCIe add in cards, fan trays and bench instruments that plug into a live 3.3 V, 5 V or 12 V backplane and need inrush control with a defined fault response. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Obsolete RF Part Replacement page.

Questions buyers ask

How is the fault current set? A resistor from ISET to ground. The published points are 200 kohm for 0.8 to 1.2 A, 100 kohm for 1.8 to 2.2 A and 49.9 kohm for 3.6 to 4.4 A, and the vendor's calculation tool covers values between them. The resistor is read as a current, so its tolerance moves the threshold directly.

What does the timer capacitor do? It sets how long the load may sit above the fault threshold before the device acts. The capacitor is charged at 1.4 microamp to a 1.4 V threshold, so the time scales with capacitance. A larger capacitor allows a longer inrush, at the cost of a longer exposure during a real fault.

Does it limit inrush on its own? Yes, through the same mechanism. The pass FET is held in regulation while the output capacitor charges, and the timer bounds how long that state may last. The value of the output capacitor therefore sets the required timer, not the other way round.

Can two of these be paralleled for more current? Not safely. The two internal FETs will not share current evenly because their on resistances differ, and each device has its own fault timer. Above 5 A the usual route is a controller with an external FET, which is a different family.

What happens on a short circuit? The current folds back to the 3 to 7.5 W power limit, the timer runs, and when it expires the TPS2421-1 latches off with FLT asserted. The latch is cleared by cycling the enable pin, which on most cards means removing and reinserting it.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.