Contact Us

TPS2051BDBVR

Brand: Texas Instruments
Texas Instruments TPS2051BDBVR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS2051BDBVR — Power Management & Signal Chain | Superb Automation

TPS2051BDBVR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS2051BDBVR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS2051BDBVR: 0.5 A current limited power switch in SOT-23

TPS2051BDBVR is a single channel current limited high side power switch in a SOT-23 body of 5 pins. It sits between a 2.7 V to 5.5 V rail and a load that may be shorted, and it reports the fault on an open drain flag.

Order code and package

Order codeTPS2051BDBVR, DBV package, 3000 pieces on a large reel
BodySOT-23, 2.90 mm by 1.60 mm, five leads
Channel countOne switch, active high enable
Lead finishNIPDAU or SN, MSL level 1 at 260 C
Vendor temperatureOrderable table states -40 C to +125 C, the feature list states -40 C to +85 C ambient

Electrical parameters that decide the application

Input range2.7 V to 5.5 V, undervoltage lockout holds the switch off below the floor
On resistance70 mOhm typical and 135 mOhm maximum in the D and DGN bodies at 0.5 A; 95 mOhm typical and 140 mOhm maximum in DBV
Current limit0.75 A minimum, 1 A typical, 1.25 A maximum at 25 C; 0.7 A minimum and 1.3 A maximum over the full range
Rise time0.6 ms typical into 1 uF with a 10 ohm load at 5.5 V, 1.5 ms maximum
Turn on delay3 ms maximum into 100 uF with a 10 ohm load
Supply current1 uA maximum with the switch off, 95 uA maximum with it on
Fault flagOpen drain, active low, deglitched, no pulse during power up

Family variants and how they differ

TPS2041BSame 0.5 A switch with an active low enable, the pair exists so a board can pick polarity
TPS2052BTwo 0.5 A channels in one body, each with its own flag
TPS2054BFour 0.5 A channels in a 16 pin SOIC
TPS20xxC familyLater generation with plus or minus 20 percent fixed limits and reverse current blocking
TPS2553Adjustable limit from a resistor when a fixed 1 A threshold is the wrong fit

Points to check before this part goes on a BOM

The 0.5 A figure is a continuous switch rating, not a promise that any 0.5 A load will start. At 0.5 A the DBV body drops 47.5 mV at the typical 95 mOhm and 70 mV at the 140 mOhm maximum, so the load sees between 4.93 V and 4.86 V on a 5 V rail and the part dissipates 35 mW at worst. That is a switch loss, and it belongs in the rail budget before the load regulator is chosen.

Current limit is the number that decides whether a product works in the field. The window runs from 0.75 A to 1.25 A at room temperature, which is a 67 percent spread around the 1 A typical point. A load that draws 0.9 A steadily will sit in constant current on a part at the bottom of the window and never reach its operating point, while the same load is comfortable on a part at the top. Any load above roughly 0.6 A belongs on the 1 A rated member of the family rather than this one.

Start up into capacitance is the second trap. The rise time is 0.6 ms typical with a 1 uF load, and the internal charge pump holds the gate ramp so the inrush stays under the limit. A 100 uF bank needs the same charge in the same ramp, so peak current rises by the ratio of the capacitances. The 3 ms turn on delay quoted for a 100 uF load is the honest figure, and a load above a few tens of microfarads should be checked on the bench with the actual capacitor rather than assumed from the 1 uF line.

The flag is open drain and active low, so it needs a pull up to the logic rail. It is deglitched, which means a short overload is filtered rather than reported on the pin, and the flag does not glitch during power up while the internal reference settles. A controller that treats the flag as an interrupt should also read the output voltage, because a switch in constant current with the flag asserted is not the same fault as a switch that has shut down thermally.

Thermal behaviour is bounded by the body, not by the current rating. The DBV package has no exposed pad, and the datasheet gives 208.6 C/W junction to ambient for it, so 35 mW at 0.5 A raises the junction by 7.3 C. The same switch in a short circuit dissipates the full limit times the input voltage until the thermal circuit trips, which is 5 W at 5 V and 1 A, and that is why the thermal shutdown exists rather than a foldback scheme.

Reverse current is blocked. The datasheet lists zero reverse leakage with the output above the input and the switch off, so a rail that is held up by a second source cannot push current back through this part. That matters when the same node is fed by a battery and an adapter, and it is also why the part can sit at the output of a USB connector without a second blocking device.

The enable pin is active high on this member and the input threshold is 2 V with 0.8 V on the low side, so it works from 2.7 V logic without a level shifter but not from a 1.8 V GPIO. The counterpart TPS2041B carries the active low enable, and mixing the two on one bill of materials is a common assembly error because the bodies and the marking are otherwise hard to tell apart.

Supply current with the switch off is 1 uA maximum, which is what a standby rail needs, and 95 uA maximum with the switch on, which is the charge pump that drives the gate. Neither figure includes the load. On a battery product the 95 uA is 0.83 Ah over a year, so the switch itself is not the reason to leave a rail enabled when the load is asleep.

The orderable addendum and the feature list disagree on temperature, and the addendum is the one to quote. The feature list was written for the original release and states -40 C to +85 C ambient, while the addendum dated 2026 lists -40 C to +125 C operating junction temperature for every orderable code. Those are two different measurements: the ambient figure describes the board the part was qualified on, and the junction figure describes the die. A customer asking whether the part can run at 100 C ambient is really asking about the board and the copper, and the answer is that the junction has to stay under 125 C, which at 35 mW of dissipation and 208.6 C/W is a 7 C rise and not the limit.

Where this order code fits

The part belongs on a 5 V or 3.3 V rail that feeds a connector, a peripheral bay or a hot plug card where a short is a real field event rather than a test bench accident. It is the cheapest way to add a limit and a flag to a port that has neither. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the BOM Shortage Recovery page.

Questions buyers ask

What replaces it if the reel is short? The TPS2051C is pin for pin in DBV with a tighter limit window, and the TPS2553 covers the case where the limit has to be set by a resistor.

Can two channels share one flag? Only with a wired OR into a single pull up, and then the controller loses the information about which channel faulted.

Is the part rated for 5.5 V continuously? Yes, 5.5 V is inside the operating range, and the absolute maximum is above it, but the drop across the switch grows with current and the thermal budget still applies.

Does it latch off after a fault? No, this member retries automatically once the overload is removed and the junction has cooled, so a permanent short causes a hiccup rather than a latched off rail.

Is the G4 or A suffix a different part? No, those are packing and lead finish variants of the same die, and the electrical table applies to all of them.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Pin to Pin Cross Reference page sets out the checks that keep a substitute from failing on the bench.