Contact Us

TPS16632RGER

Brand: Texas Instruments
Texas Instruments TPS16632RGER is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS16632RGER — Power Management & Signal Chain | Superb Automation

TPS16632RGER

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS16632RGER from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS16632RGER: 60 V, 6 A eFuse with adjustable power limiting

TPS16632RGER is an integrated hot swap switch with protection in a VQFN body of 24 pins. A 31 mOhm FET with a current limit that is set between 0.6 A and 6 A by one resistor, plus a power limit loop that folds the current back as the voltage across the switch rises. The body is 4 mm by 4 mm, the input range is 4.5 V to 60 V, and the part carries UL 2367 recognition and IEC 62368-1 certification.

Order code and package

TPS16632RGERactive, production, VQFN 24 pins, 3000 pieces on a large reel
Lead finishNIPDAU, RoHS Yes
Moisture levelLevel 1, 260 C, unlimited floor life
Temperatureminus 40 to 125 C
CertificationUL 2367 recognised, file E169910, and IEC 62368-1 certified
Body4.00 mm by 4.00 mm with a thermal pad

Electrical parameters that decide the application

Input voltage4.5 V to 60 V operating, 67 V absolute maximum
On resistance31 mOhm integrated FET
Current limit0.6 A to 6 A, set by RILIM, 7 per cent accuracy, RILIM of 3 kOhm or more
Limit example9 kOhm gives 1.84 A to 2.16 A at 1 V across the switch
Power limitingplus or minus 6 per cent on the TPS16632 and TPS16637
Current monitorIMON output, 27.9 uA per amp between 0.6 A and 2 A, 6 per cent accuracy
Under and over voltage2 per cent accuracy, adjustable
Overvoltage clampfixed 39 V maximum on the TPS16632
Quiescent current21 uA in shutdown
Fault responselatch off or auto retry, selected by the MODE pin

Family variants and how they differ

TPS16630no power limiting, the basic member
TPS16632power limiting plus a fixed 39 V overvoltage clamp, the member on this page
TPS16637power limiting with an adjustable clamp
dVdT pinsets the output slew rate and therefore the inrush
MODE pinlatch off or auto retry after a fault
IMONa resistor converts the monitor current into a voltage for an ADC

Points to check before this part goes on a BOM

The power limiting loop is what separates this part from a plain hot swap switch. A 60 V rail plugged into a 1 mF capacitor asks for a very large current for a short time, and the loop folds the current back so the product of switch voltage and current stays inside the FET safe operating area instead of tripping the limit and latching.

The current limit is set by one resistor to ground, and the vendor floor is 3 kOhm. Below that the part is outside its specified range, so a build that needs more than 6 A cannot get there by lowering the resistor; it needs a second device or a different part.

At 6 A the 31 mOhm switch drops 1.1 W. In a 4 mm by 4 mm body that is the thermal limit rather than the electrical one, and the pad has to reach a copper area before the 6 A figure means anything in a 60 C cabinet.

The current monitor is a current output, not a voltage, and its gain changes between the 0.6 A to 2 A range and the range above 2 A. A firmware that reads the monitor with one gain constant will over-read at low current or under-read at high current depending on which constant it picked.

The overvoltage clamp on this member is fixed at 39 V. On a 48 V rail that clamp never fires, which is fine, and on a 24 V rail it protects the downstream converters from a regulator failure. A build that needs a different clamp point needs the adjustable member.

Auto retry against latch off is a system decision. A retry that keeps a shorted load energised in pulses can damage the load, while a latch that requires a power cycle can strand a remote unit. The MODE pin makes it a build decision rather than a part number decision.

Level 1 moisture with unlimited floor life is worth noting against the rest of this band, most of which is level 2 or 3. A prototype line that opens a reel and comes back to it a month later does not have to bake this part.

Sizing the current limit for a real load

The limit has to sit above the maximum load current with margin for the tolerance and below the continuous rating of the connector and the trace. A 3 A load with a 7 per cent limit window needs a resistor that puts the window at 3.6 A to 4.0 A, not at 3.2 A, or a warm start trips the limit.

Inrush is the other side of the same decision. The dVdT capacitor sets the ramp, and a slower ramp keeps the inrush inside the limit without raising it, which is usually the better trade than a higher limit.

What the certifications cover

UL 2367 recognition covers the switch as a component in a limited power circuit, and IEC 62368-1 certification covers the equipment safety standard. Both depend on the external components around the part, so the certificate is a starting point rather than a blanket approval.

The file number and the certificate belong on the compliance file, and a build that changes the sense resistor or the dVdT capacitor is a different configuration as far as the safety review is concerned.

The inrush arithmetic

Charging a 1 mF load to 48 V in 10 ms takes an average of 4.8 A, which is inside the 6 A limit, but the instantaneous current at the start of the ramp is higher because the capacitor looks like a short. The power limiting loop is what keeps the switch inside its safe area during that first millisecond.

A dVdT capacitor that stretches the ramp to 50 ms halves the average inrush and moves the thermal load from the FET into the ramp time. The cost is that the downstream converter starts 40 ms later, which matters when power good is used to sequence the rest of the board.

The limit and the ramp are separate knobs and should be set in that order. Set the limit from the steady load and the connector rating, then stretch the ramp until the inrush fits under it. A build that raises the limit to make a fast start works is trading a protected load for a shorter start, and the switch is the part that pays for it on the next hot plug.

Where this order code fits

The order code is used on 24 V and 48 V industrial rails, telecom line cards and battery backed equipment where a hot plugged load must not take the bus down. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Component Lead Time Solutions page.

Questions buyers ask

Can two parts be paralleled for more than 6 A? Not by tying the outputs together directly. The two switches do not share current evenly, and the one with the lower threshold carries most of it. Load sharing needs a controller per path.

What does the IMON pin output? A current proportional to the load, 27.9 uA per amp in the 0.6 A to 2 A range. A resistor to ground turns it into a voltage for an ADC.

Is the 39 V clamp adjustable? Not on this member. The TPS16637 has the adjustable clamp, and the TPS16630 has no power limiting loop.

Does it protect against reverse current? The integrated FET blocks current in one direction only. A load that can back feed the bus needs an external blocking device or a part with reverse protection.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.