INA240A2EDRQ1
Product Specifications
INA240A2EDRQ1
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA240A2EDRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA240A2EDRQ1: the automotive 50 V/V gain, and the row that carries two moisture levels
INA240A2EDRQ1 is the automotive qualified 50 V/V option in the 8 pin SOIC on a 2500 piece large reel, AEC-Q100 temperature grade 1 from minus 40 to plus 125 degrees. The E in the code marks the variant the addendum lists separately from INA240A2QDRQ1, and the two share the gain, the body and the qualification.
The row to read before the reel reaches the line is the moisture column. The addendum prints INA240A2EDRQ1 at level 3 with a 168 hour floor life and the row beside it, the .A suffix, at level 2 with a one year floor life. A line that plans a week of production around the reel and assumes level 2 has to check the bag label rather than the part number, and a level 3 part that has been open for longer than 168 hours needs a bake.
INA240A2EDRQ1 as the vendor document publishes it
| Gain | 50 V/V fixed |
| Gain error | 0.05 per cent typical, 0.20 per cent maximum |
| Gain drift | 2.5 ppm per degree maximum |
| Nonlinearity | 0.5 ppm typical, 2.5 ppm maximum |
| Offset voltage | 5 microvolts typical, 25 microvolts maximum, referred to the input |
| Offset drift | 250 nanovolts per degree maximum |
| Common mode rejection, DC | 120 dB minimum, 132 dB typical |
| Common mode rejection at 50 kHz | 93 dB |
| Power supply rejection | 1 microvolt per volt typical, 10 maximum |
| Input bias current | 90 microamps |
| Common mode range | minus 4 volts to plus 80 volts, independent of the supply |
| Supply range | 2.7 volts to 5.5 volts |
| Quiescent current | 1.8 milliamps typical, 2.4 milliamps maximum |
| Bandwidth at 3 dB | 400 kHz at every gain |
| Bandwidth at 2 per cent distortion | 100 kHz at every gain |
| Slew rate | 2 volts per microsecond |
| Settling to 0.5 per cent | 9.6 microseconds at the 20 V/V gain, 9.8 at the 200 V/V gain |
| Voltage noise density | 40 nanovolts per root hertz |
| Reference divider accuracy | 0.01 per cent typical, 0.1 per cent maximum |
| Reference input range | 0 volts to the supply rail |
| Swing to the positive rail | 50 millivolts typical, 200 maximum into 10 kohm |
| Swing to ground | 1 millivolt typical, 10 maximum |
| Stable load capacitance | 1 nanofarad |
| Temperature range | minus 40 to plus 125 degrees |
| Vendor status | active, 2500 piece large reel |
| Catalogue code | INA240A2EDRQ1 |
| Vendor string | INA240A2EDRQ1, level 3 on one row and level 2 on the .A row |
| Qualification | AEC-Q100 temperature grade 1, minus 40 to plus 125 degrees |
| Marking | 240A2E |
| Moisture level | level 3, 168 hour floor life on the printed row |
Grade 0, grade 1 and what the Q1 suffix buys
INA240A2EDRQ1 carries the automotive suffix, so the qualification is AEC-Q100 rather than the industrial flow: temperature grade 1 from minus 40 to plus 125 ambient for the SOIC codes, and temperature grade 0 from minus 40 to plus 150 for the TSSOP code INA240A2QPWRQ1. The ESD classification is HBM level H2 and CDM level C5, and the device is functional safety capable with the documentation that a safety case asks for.
The grade is the purchase decision, not the gain. A grade 1 part is specified to 125 degrees ambient and a grade 0 part to 150, and the 25 degree difference is the whole of the price difference in most lines. The marking differs as well: the grade 1 codes print 240A1Q through 240A4Q and the grade 0 code prints Q240A2, which matters on a board where two grades of the same gain sit side by side. Moisture level is 2 with a one year floor life on most rows, and the INA240A2EDRQ1 addendum prints level 3 with a 168 hour floor life on one row and level 2 on the row beside it, so the bag label decides.
Four hundred kilohertz on all four gains
The bandwidth of INA240A2EDRQ1 is 400 kHz at 3 dB and 100 kHz at 2 per cent distortion, and neither figure changes with the gain option. That is unusual for a current sense amplifier, where the gain stage normally trades bandwidth for gain, and it comes from the difference amplifier topology: the four gains are set by internal resistors on one die, so the 20 V/V and the 200 V/V option have the same pole.
The number that matters in a motor drive is the settling time, 9.6 microseconds at the 20 V/V gain and 9.8 at the 200 V/V gain to 0.5 per cent of the final value. A 20 kHz switching frequency leaves a 25 microsecond on-time at 50 per cent duty, and 9.6 microseconds is 38 per cent of it, so the sample has to be taken in the later part of the window. At 100 kHz switching the on-time is 5 microseconds and the output is still moving when the sample is taken, so the reading is low by whatever the output has not yet reached. A drive that samples at that speed needs a shorter settling time, not a faster converter.
Minus four volts of common mode, and why a solenoid needs it
The input of INA240A2EDRQ1 is specified from 4 volts below ground to 80 volts above it, and the window does not move with the supply rail. The negative end is there for the flyback period of a solenoid or a relay: when the switch opens, the low side of the coil swings below ground and the shunt with it, and a monitor that stops at zero volts loses the reading for exactly the part of the cycle where the current is decaying.
The positive end covers a 48 volt telecom bus and a 72 volt battery pack with margin, again from a 3.3 or 5 volt rail, because the input divider is internal and the common mode window is independent of the supply. What the window does not cover is a bus that rings above 80 volts: above the limit the part is not specified, and the current that flows through the protection network becomes the error. A bus with a transient above 80 volts needs a series resistor on both inputs or a different part, and the decision belongs in the requirements rather than in a note on the drawing set.
Two bodies, eleven order codes and the rows the addendum marks obsolete
INA240A2EDRQ1 comes in an 8 pin TSSOP of 3.00 by 4.40 millimetres and an 8 pin SOIC of 4.90 by 3.91 millimetres, both at moisture level 2 with a 260 degree peak and a one year floor life. The four gains are available in both bodies, so the body is a thermal and a footprint decision rather than a functional one: the TSSOP spreads heat better on a small board, the SOIC is easier to inspect and to rework by hand.
The addendum read for this page carries obsolete rows that are easy to order by accident. The tube codes INA240A2PW, INA240A3PW, INA240A4PW and the SOIC tube INA240A4D are printed Obsolete while the reel codes of the same gain and body are active, and INA240A2PWR is printed active with a dash in the quantity column instead of a reel size. A line that needs a few pieces for a pilot usually reaches for the tube, and that is exactly the row that is closed. Read the status column before the quantity column.
Twenty five microvolts against a ten millivolt full scale
The offset of INA240A2EDRQ1 is 5 microvolts typical and 25 microvolts maximum referred to the input, with a drift of 250 nanovolts per degree maximum. Against a 10 millivolt shunt drop, which is the smallest full scale the family is specified for, the maximum offset is 0.25 per cent of full scale and the typical part is 0.05 per cent.
The drift row deserves the same arithmetic. At 250 nanovolts per degree over the 165 degree window from minus 40 to plus 125, the drift term is about 41 microvolts, which is larger than the maximum room temperature offset. A single point calibration at 25 degrees therefore buys less than the drift spec, and a channel that has to hold 0.5 per cent over temperature either runs a smaller temperature window, calibrates at the operating temperature, or uses the zero drift architecture for what it is: a guarantee that the offset does not wander, not a guarantee that it is zero.
Where a PWM rejecting shunt monitor earns its place, and where it stops
INA240A2EDRQ1 suits four kinds of channel: the phase current of a three phase motor drive, where the common mode steps at every switching edge; a solenoid or valve driver, where the current decays through a diode and the low side goes below ground; a telecom rectifier or a 48 volt power shelf, where the bus sits above the logic supply; and an actuator or pressure regulator loop that closes on current rather than on position.
It stops at four things. There is no digital output, so a converter and its reference are part of the channel. There is no isolation, so a mains referenced shunt needs an isolator behind the amplifier. The quiescent current of 1.8 milliamps typical rules out a battery instrument that sleeps. And the 10 millivolt full scale floor sets the shunt: at 10 millivolts and 25 microvolts of maximum offset, a shunt that develops less than 10 millivolts at the working current does not get more accurate by being larger, it gets slower and hotter. Our amplifier cross reference page covers the parts that trade one of those four for something else.
Two moisture levels under one part number is a receiving inspection question, not a purchasing one. Our traceability report page covers the label and the certificate that travel with an automotive reel, and the amplifier cross reference page covers the other gains in the qualified family.
Is the moisture level 2 or 3? The addendum prints both on adjacent rows, so the answer is on the bag label. Level 3 gives 168 hours of floor life after the bag is opened and level 2 gives one year.