Contact Us

INA125U2K5

Brand: Texas Instruments
Texas Instruments INA125U2K5 is a power management component designed for Industrial Automation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

INA125U2K5 — Power Management & Signal Chain | Superb Automation

INA125U2K5

Texas Instruments — Power Management & Signal Chain

Product Overview

The INA125U2K5 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

INA125U/2K5: the bridge amplifier on a 2500 piece reel

This is the production carrier of the surface mount bridge amplifier: the SO-16 body with the integrated reference, 2500 pieces on a large reel. The part is the same die as the DIP and the tube rows, so the reel is a logistics decision: one carrier, one label, one moisture record for a build that would otherwise open more than sixty tubes.

A bridge instrument built in volume carries one of these per channel, and the reference on each die is trimmed separately, so a four channel board has four references. That is worth knowing because a multi channel instrument that compares channels against each other is comparing four independent references, and the channel to channel accuracy is the reference spread rather than the converter's.

The INA125U/2K5 rows as the addendum publishes them

Part classInstrumentation amplifier with precision voltage reference
Vendor statusACTIVE, production data
Data sheetSBOS060
Catalogue stringINA125U/2K5 with the slash, INA125U2K5 without
Reference voltages1.24 V, 2.5 V, 5 V, 10 V by pin strap
Gain equationG = 4 + 60 kΩ divided by RG
Input offset voltage250 µV maximum
Offset drift2 µV per degree maximum
Quiescent current460 µA
Supply rangeSingle supply 2.7 V to 36 V
BodySOIC, D outline, 16 pins
Carrier2500 pieces on a large reel
Tube siblingINA125U, 40 pieces per tube
Grade siblingINA125UA/2K5, tighter bin on the same reel
Moisture levelLevel 3, 260 degrees, 168 hour floor life
Temperature rangeMinus 40 to plus 85 degrees

A reel of 2500 sixteen pin parts is a substantial object, and it is the carrier that makes a four channel board practical at volume. The alternative, forty piece tubes, means a tube per sixty boards and a feeder change every hour on a fast line, which is a throughput cost that dwarfs the price difference between the carriers.

Four references on one board

Each INA125 carries its own reference, and the reference is trimmed to the tap voltage within the vendor's tolerance rather than to a common value. A four channel instrument that measures four bridges ratiometrically is fine, because each channel cancels its own reference. A four channel instrument that compares channels, or that multiplexes two bridges into one channel, needs to know the spread, and the spread is not published per part but is bounded by the reference tolerance.

The practical implication is that a channel to channel comparison should be made against a common external reference or with a calibration step, and a ratiometric measurement should stay within one channel. That is a system rule rather than a part limitation, and it is the kind of rule that is discovered late if the architecture is drawn around a single reference.

Reel handling on a wide body SO-16

SO-16 tape is wider than SO-8 tape and the pocket is deeper, so the feeder and the nozzle are different from the SO-8 line. A line that has been set up for SO-8 parts needs a tooling change for this reel, and the change is a one time cost per build rather than per reel. The first article check should confirm the orientation, because a reversed sixteen pin part is less obvious than a reversed eight pin part.

The moisture rating is level 3, and a wide body part absorbs moisture more slowly than a thin one but the floor life is the same. The dry cabinet has to take a 330 mm reel, and a build that opens the reel once a month is using a small fraction of the floor life each time, which is the argument for the reel over the tubes.

Excitation headroom on a 5 V rail

The most common configuration for this part is a 5 V supply with the 2.5 V tap, which gives a 350 Ω bridge 7 mA and leaves the amplifier 2.5 V of output swing. The 5 V tap on the same rail is impossible for a bridge that returns to ground, because the excitation would sit at the supply and the amplifier would have no headroom. The 1.24 V tap is useful for a low power bridge that cannot take 2.5 V, and the 10 V tap needs a supply above 12 V.

The choice is therefore made by the bridge and the supply together, and it is fixed in copper. A board that might need either 2.5 V or 5 V excitation should bring both taps to a jumper rather than commit in copper, because a re-spin of a production board costs more than a jumper.

Buying INA125U/2K5

The reel is active and the tube is active. The grade is the plain bin, and the A bin on the same reel is a separate string. The purchase order should name the carrier and the grade, and the quantity in pieces rather than reels.

For a bridge instrument in a regulated market, our component traceability report page covers what we record per reel, and the component cost page sets out how we compare an integrated front end against a discrete reference and amplifier on total cost.

Testing a ratiometric bridge channel at volume

A ratiometric channel can be tested without a temperature calibration, and that is where the cost saving of the integrated front end appears. The test is a two point check at the connector with a resistor substitution for the bridge: one point at the bridge's zero, one at full scale, and the gain and offset are computed from the two readings. Because the reference and the excitation are the same node, the test does not depend on the absolute reference value, and a channel that passes at room temperature will hold over the specified range to within the drift budget.

The drift budget is what the test cannot check, and it is where a sample based qualification comes in. A batch of ten units cycled over the operating range establishes the drift, and the production test then only needs the two point check. That split is the standard way to test a bridge instrument at volume, and it is cheaper than a per unit thermal test by an order of magnitude.

The second test that is worth doing per unit is the sleep and wake sequence. A channel that reads correctly after a wake up of 500 microseconds but not after 5 milliseconds has a reference settling problem, and the test point catches it before the instrument is potted. The test costs a relay and a delay, and it catches the one failure that a functional test at steady state misses.

The third is the excitation current. A bridge that draws more than expected loads the reference and pulls the excitation down, which shows up as a gain error rather than as a supply fault. Measuring the excitation voltage at the connector with the bridge connected is the cheapest way to catch a solder fault on the tap pin.

The fourth test at the connector is the reference itself. Measuring the excitation voltage at the bridge with the bridge connected confirms that the tap is strapped correctly and that the reference has not been pulled down, and it takes one probe and one reading. A channel that fails it is a board that will pass a functional test at the amplifier output and still be wrong in the field.

Questions that arrive with this part number

Whether the reel can be used across two assembly sites is the first question, and it can with care, but the moisture record has to travel with the reel. Whether the reference taps can be changed after assembly is the second, and they cannot: they are pin straps, so the choice is made in copper. The third question is the current available from the reference, which is small and needs a pass device for a 350 Ω bridge at 2.5 V.

The fourth is the slash, which is cosmetic: the vendor prints INA125U/2K5 and the catalogue may print INA125U2K5, and both are the same reel.