Contact Us

BQ76925PWR

Brand: Texas Instruments
Texas Instruments BQ76925PWR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

BQ76925PWR — Power Management & Signal Chain | Superb Automation

BQ76925PWR

Texas Instruments — Power Management & Signal Chain

Product Overview

The BQ76925PWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

BQ76925PWR: a front end that leaves the decisions to the host

The BQ76925PWR is an analogue front end for packs of three to six series cells. It does not measure in the sense of producing numbers: it level shifts, multiplexes and scales the cell voltages and hands them to the host converter, together with a calibrated reference that makes the conversion repeatable. The host owns the conversion, the thresholds and the policy, and the part owns the signal conditioning and the FET drive.

That split is deliberate. A host that already has a spare converter channel gets six cells of measurement for the cost of one small package and a few external resistors, with no second processor and no second register map to learn. What it gives up is autonomy: with the host asleep, nothing is measured, and the only protection that survives is the overcurrent comparator.

The part includes a variable gain current sense amplifier that works with a 1 milliohm sense resistor, a switchable thermistor bias, integrated balancing FETs rated for 50 mA per cell, an open wire check on the cell sense lines, and a 3.3 V regulator for the host. It comes in a 20 pin TSSOP, and the 24 pin QFN body carries the same function in a smaller footprint.

Key data for the BQ76925PWR

FunctionHost controlled analogue front end for cell measurement and balancing
Cell count3 to 6 series cells, Li-ion and lithium phosphate
Voltage pathCell multiplexer, level shifter and scaler feeding the host converter
Reference1.5 V or 3.0 V calibrated, low drift, brought out for the host conversion
Current pathVariable gain sense amplifier, works with a 1 milliohm resistor
BalancingIntegrated FETs, 50 mA per cell, set by external resistors, host controlled
ProtectionOvercurrent comparator with an adjustable threshold, alerts the host and wakes it on load connect
DiagnosticsOpen wire detection on the cell sense lines
Regulator3.3 V output for the host processor
PackageTSSOP, 20 pins, and a 24 pin QFN with the same function
OrderingBQ76925PWR, 2000 pieces on a large tape and reel; BQ76925PW, 70 pieces in a tube; both moisture level 2 with a one year floor life

The reference is the reason the numbers repeat

A host converter measures a ratio against its own reference, and that reference drifts with temperature and with the batch. Feed it a cell voltage scaled by a resistor divider and the reading carries the divider error and the reference error together. The part brings out a calibrated reference for exactly this reason: the host measures the cell against the same reference the part was trimmed to, and the two errors cancel in the conversion.

That only works if the host uses the reference for the cell channels and for nothing else. A host that shares its own supply as the reference will read the pack and the rail at once, and the difference between them will look like a cell that moves when the load changes.

The 1.5 V and 3.0 V options exist because host converters differ in their input range. A 3.0 V reference suits a converter with a 3 V full scale; a 1.5 V reference leaves headroom for a scaled signal that would otherwise clip. Choosing the wrong one does not damage anything, but a clipped channel reads a constant value at the top of the range, which is a fault that looks like a stuck cell.

Balancing at 50 mA, and what that means in a pack

Fifty milliamps per cell is a maintenance current, not a repair current. On a 5 Ah cell that has drifted 5 per cent out of balance, the difference is 250 mAh, and at 50 mA it takes five hours of balancing to remove. That is fine on a pack that rests overnight and impossible on a pack that is cycled continuously, which is why balancing is scheduled rather than run.

The current is set by external resistors, so the 50 mA figure is a ceiling rather than a setting. A pack with a small cell and a tight thermal budget runs at a lower current and accepts a longer balance window; a pack with a large cell and a short window runs near the ceiling and has to check that the resistor and the FET can take the dissipation.

The balancing FETs are also used for the open wire check. By switching a cell and watching the voltage move, the host can tell whether the sense line is connected. A sense line that is open reads a voltage that looks plausible and never changes, which on a pack with a cell balancer is a fault that only shows up as a cell that will not balance.

Where it fits in a build

Products that already have a host with a spare converter and want a low external part count: portable instruments, medical carts, robot packs, small energy storage modules, and industrial packs where the host code is already written. A pack that has to be safe with the host asleep needs a part with its own protection comparators and its own state machine instead.

Because the measurement quality depends on the host and on the divider, this is also a part where the first build tells you whether the whole chain works. On that first build the PCBA quote checklist page covers the items we confirm before a quotation becomes a build.

The sourcing side of this part is covered on the BOM scrubbing. For a pack whose measurement quality depends on a divider and a reference, that page covers how a BOM is checked before release.

Questions we get on this code

Can the host converter be the same one used for other sensors? Yes, through the multiplexer, as long as the other channels do not load the reference or the scaled cell signal. A shared reference with a long settling time is the usual cause of a reading that jumps between channels.

Does the part protect the pack on its own? Only the overcurrent comparator works without the host. Overvoltage, undervoltage and overtemperature are host decisions in this arrangement, so the host has to be running to enforce them.

What does the wake on load connect do? It brings the host out of sleep when a load is applied to the pack, which is how a product that sits idle for weeks still answers the first trigger. The threshold for that wake is set by an external component.

Is the 3.3 V regulator enough to run the host? It is intended for a microcontroller class load, not for a radio or a motor driver. The current available is limited, and a host that draws more than the regulator can give will brown out at the same moment the pack is loaded.