AMC1200STDUBRQ1
Product Specifications
AMC1200STDUBRQ1
Texas Instruments — Power Management & Signal Chain
Product Overview
The AMC1200STDUBRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AMC1200STDUBRQ1: isolated amplifier with a 250 mV input for shunt current measurement
AMC1200STDUBRQ1 is the current sense stage that puts a barrier between a high voltage bus and the controller in a SOP body of 8 pins. The part amplifies a plus or minus 250 mV shunt signal across a silicon dioxide barrier rated 4000 V peak on the AMC1200 and 4250 V peak on the B grade, with a working voltage of 1200 V peak and 10 kV per microsecond of transient immunity. Gain is fixed at 8 with 0.5 percent accuracy, nonlinearity is 0.075 percent maximum, and the high side draws 8 mA maximum from a 5 V rail.
Order code and package
| Order code | AMC1200STDUBRQ1 |
| Function | fully differential isolation amplifier, gain 8 |
| Input range | plus or minus 250 mV, for a shunt resistor |
| Isolation | 4000 V peak on the AMC1200, 4250 V peak on the B grade, per UL1577 and VDE V 0884-10 |
| Working voltage | 1200 V peak |
| Transient immunity | 10 kV per microsecond minimum |
| High side supply | 4.5 to 5.5 V, 8 mA maximum |
| Low side supply | 2.7 to 3.6 V or 4.5 to 5.5 V |
| Package | SOP, 8 pins, wide body |
| Temperature range | minus 40 to plus 105 C |
| Datasheet | SBAS542 revision D |
| Bandwidth | 60 kHz minimum small signal |
Electrical parameters that decide the application
| Nonlinearity | 0.075 percent maximum at 5 V, which is 0.19 mV on the 250 mV input range |
| Offset | 1.5 mV maximum, which is 0.6 percent of the input range before any calibration |
| Noise | 3.1 millivolts RMS typical, or 1.24 percent of the 250 mV range, about six and a half bits per sample |
| Gain error | 0.5 percent |
| Common mode rejection | 108 dB, and the common mode here is the bus voltage |
| Output | differential, so the low side can drive a converter without a single ended conversion |
| High side current | 8 mA maximum, so the isolated supply has to deliver 40 mW continuously |
| Creepage | wide body package, which is where the working voltage comes from |
| Bandwidth | 60 kHz minimum, which is enough for motor phase current and not for a switching transient |
| Package | SOP 8 wide body, 5.85 mm by 7.50 mm |
Points to check before this part goes on a BOM
Three and a half millivolts of RMS noise against a 250 mV input range is 1.24 percent, or about six and a half bits of the shunt signal per sample. At 60 kHz of bandwidth that is a current control front end, not a metering front end, and averaging has to be part of the plan before the figure improves.
One and a half millivolts of maximum offset is 0.6 percent of full scale, and at a 1 mOhm shunt that is 1.5 A of apparent current that is not flowing. The offset has to be calibrated out at zero current, which means the product needs a zero current state during production test.
The high side draws 8 mA maximum at 5 V, so the isolated supply has to deliver 40 mW continuously. A transformer driver and a small winding sized on a typical figure rather than on the maximum is the usual cause of a stage that works at 25 C and browns out at 100 C.
Working voltage of 1200 V peak is not the isolation test voltage. A 4000 V peak rating is a one minute withstand figure, while the barrier is expected to hold 1200 V continuously, so a 1500 V bus needs a part with a higher working voltage rather than a part with a higher test voltage.
Sixty kilohertz of bandwidth is enough to close a motor current loop and not enough to see a switching transient. A short circuit event is over before this amplifier has settled, so the fast protection path has to come from somewhere else.
The B grade isolates to 4250 V peak against 4000 V peak on the standard part, and both share the same board. A product whose safety case cites the higher number has to order the B code or the paperwork does not match the part.
Where this order code fits
Current sense stages that need a barrier usually weigh this part against the 2 V input members of the same family, which suit voltage sensing rather than a shunt. Boards comparing it with a neighbouring part start from our Amplifier Cross Reference page, and boards replacing a part that has gone end of life start from the How to Verify a Drop in Replacement page.
Questions buyers ask
Is 4000 V peak a continuous rating? No. It is a withstand figure. The continuous working voltage is 1200 V peak, and that is the number a 1500 V bus has to be checked against.
How much resolution does the shunt signal get? About six and a half bits per sample from the 3.1 mV RMS noise on a 250 mV range; averaging and calibration are what turn that into a usable current reading.
SUPERB holds and sources this Texas Instruments line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a line is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.