Slotted Wire Duct and Cable Trunking for Panel Wiring

Slotted PVC wire duct for panel wiring, in a narrow 5 mm slot and a wide 7.9 mm slot, with eight wall sizes from 1 x 3 in to 4 x 4 in. Bases and covers are separate part numbers, and the duct is lead free PVC rated UL94 V-0 for 50 C continuous use. Finger score lines let a side wall be opened where a wire leaves the run.
quote now

Product Specifications

Product Overview

Panel wiring without duct is a bundle that sags, rubs and gets reworked every time a wire is added. Slotted duct turns the bundle into a route with a defined width, a cover and an exit point at every 10 mm, and it is the difference between a panel that can be traced and one that has to be buzzed out wire by wire.

The duct is a U channel with fingers cut along both side walls. The fingers flex, so a wire can be pushed out at any slot without cutting the wall, and the score lines above and below the slot let a whole section of wall be snapped off where a large bundle leaves. A cover clips over the top and hides the run.

Two slot widths cover the work. The 5 mm narrow slot, the type F, suits control and signal wire up to about 1.5 mm squared and holds the wire in place. The 7.9 mm wide slot, the type G, takes larger wire and lets a bundle turn out of the duct without chafing, and it is the one used on a power section.

Sizing is by fill. A duct should not be more than about 40 percent full of wire by cross section, because the cover has to close and a full duct cannot be added to later. The wall height matters as much as the width: a 2 in wall holds roughly twice the wire of a 1 in wall at the same width.

Key Specifications

ParameterType F, narrow slotType G, wide slot
Slot width5 mm7.9 mm (0.31 in)
Wall sizes1 x 3, 1 x 4, 2 x 3, 3 x 3, 4 x 4 in1 x 2, 1.5 x 2, 1.5 x 3 in
Metric sizes25 x 76, 25 x 102, 51 x 76, 76 x 76, 102 x 102 mm25 x 51, 38 x 51, 38 x 76 mm
MaterialLead free PVCLead free PVC
FlammabilityUL94 V-0UL94 V-0
Continuous use temperature50 C50 C
Wall thickness2 mm nominal2 mm nominal
Length6 ft (1.8 m) per piece6 ft (1.8 m) per piece
CoverSeparate part number, same lengthSeparate part number, same length
MountingMoulded mounting holes in the baseMoulded mounting holes in the base
ColourWhite, grey or black by suffixWhite, grey or black by suffix
StandardNFPA 79 flame retardant requirementNFPA 79 flame retardant requirement

Included Models and Order Codes

The part number carries the size and the slot type: F is the narrow 5 mm slot, G is the wide 7.9 mm slot, and the two figures after the letter are the nominal width and height in inches. The suffix WH6 is white and 6 ft. Covers are ordered on a separate line with the same width and length, because a base without a cover leaves the run open.

Part NumberTypeNominal W x H (in)Nominal W x H (mm)Slot widthLength
F1X3WH6Type F1 x 325 x 765 mm6 ft
F1X4WH6Type F1 x 425 x 1025 mm6 ft
F2X3WH6Type F2 x 351 x 765 mm6 ft
F3X3WH6Type F3 x 376 x 765 mm6 ft
F4X4WH6Type F4 x 4102 x 1025 mm6 ft
G1X2WH6Type G1 x 225 x 517.9 mm6 ft
G1.5X2WH6Type G1.5 x 238 x 517.9 mm6 ft
G1.5X3WH6Type G1.5 x 338 x 767.9 mm6 ft

Covers and the Same Width in Both Slot Types

The cover is a separate line because it is fitted after the wire is in, and a panel that is wired in stages needs the cover to arrive at the same time as the base. The cover part number starts with C and carries the same width figure as the base. A cover from a 1.5 in base does not fit a 1 in base, even though the slot type is the same.

Cover Part NumberFits base widthMaterialLengthColour
C1X2WH61 in (25 mm)Lead free PVC6 ftWhite
C1X3WH61 in (25 mm)Lead free PVC6 ftWhite
C1X4WH61 in (25 mm)Lead free PVC6 ftWhite
C1.5X2WH61.5 in (38 mm)Lead free PVC6 ftWhite
C1.5X3WH61.5 in (38 mm)Lead free PVC6 ftWhite
C2X3WH62 in (51 mm)Lead free PVC6 ftWhite
C3X3WH63 in (76 mm)Lead free PVC6 ftWhite
C4X4WH64 in (102 mm)Lead free PVC6 ftWhite

Key Features

Two slot widths – 5 mm for control wire and 7.9 mm for power, on the same mounting pattern, so a panel can change slot type without moving the holes.

Fingers that flex – A wire is pushed out at any slot without cutting the wall, which is what makes a late change possible after the cover is on.

Score lines for large exits – The wall above and below the slot snaps off cleanly where a bundle leaves, so the edge stays square instead of being cut with a knife.

Lead free PVC, UL94 V-0 – The material carries the flame rating that NFPA 79 asks for, and the 50 C continuous limit is the number to check against a warm panel.

Eight wall sizes – From 1 x 3 in to 4 x 4 in, which covers a signal run and a power run in the same cabinet.

Mounting holes moulded in – The base is screwed down through holes that are already in the part, so the run can be laid out with a tape measure and a drill.

Covers on separate lines – A cover is ordered with the base and fitted after the wire, which keeps a staged build from losing covers on site.

Colour by suffix – White, grey and black are available, so a duct run can match the panel finish without painting.

Applications

Duct is used on every panel that has more than a handful of wires. The four cases below show where the slot width and the wall height change the answer.

Control panels and machine tools – A 2 x 3 in type F run carries the 24 V control wires, and the 5 mm slot holds each wire where it leaves the duct.

Power distribution sections – A 1.5 x 3 in type G run takes the larger power wire, and the 7.9 mm slot lets a bundle turn out without chafing the insulation.

Panel retrofits – Duct is added to an existing plate through the moulded holes, and the cover is fitted after the new wires are pulled, so the run stays closed.

Telecom and instrument cabinets – A 1 x 4 in type F run gives height without width, which suits a deep cabinet with a narrow wireway between terminal rows.

A duct run is laid out before the components are screwed down, and the SUPERB PCB panel drawing shows the slot type, the width and the exit points so the wire lengths are cut once. On the SUPERB PCBA route the duct is fitted after the plate is painted and before the harness is pulled, which keeps swarf out of the run.

Sourcing and Cross-Reference

Duct is a low cost part that sets the layout of a panel, so the sizes are usually chosen together with the terminal blocks and the cable clamps. A run that is too narrow is filled before the panel is finished, and a run that is too wide takes space that the components needed.

The cover is the line that gets forgotten. A base is ordered by the metre and a cover by the same length, and a panel that arrives without covers cannot be signed off. The two are separate part numbers because the cover is fitted last, and the width figure has to match exactly.

The slot width is a working decision, not a rating. A 5 mm slot holds a control wire and a 7.9 mm slot lets a power bundle leave without rubbing. Mixing the two on one plate is normal, and both types share the same mounting holes and the same 6 ft length.

SUPERB Assembly cuts the wall at the score line rather than with a knife, keeps the fill under 40 percent and fits the cover after the point to point check, because a cover that goes on early gets removed again and the clips wear out.

Q: Can you supply G1.5X3WH6 bases with the matching C1.5X3WH6 covers, 20 pieces of each, cut to 1.8 m?

A: Send the panel drawing, the wire sizes, the number of wires per run and the space between terminal rows. The SUPERB Tech desk replies with the slot type, the wall size and the cover lines, and checks the fill so the run can still be added to.

Why Buy Wire Duct Through SUPERB

  1. Base and cover on one order: Both lines are quoted together with the same width and length, so the panel does not arrive with open runs.
  2. Slot width matched to the wire: The 5 mm and 7.9 mm types are quoted against the wire size and the fill, not against what is in stock.
  3. Flame rating confirmed: Lead free PVC with a UL94 V-0 rating and a 50 C continuous limit, which is what the panel standard asks for.
  4. Sizes from 1 x 3 in to 4 x 4 in: A signal run and a power run are covered from the same range, with the same mounting pattern.
  5. Panel build support: The assembly team lays out the duct, cuts the exits at the score lines and fits the covers after the point to point check, so the run is closed when the panel ships.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Screw Terminal Blocks and Pluggable Connectors, Cable Clamps and Harness Ties for Internal Wiring, Wire Ferrules and Crimp Sleeves for Terminal Blocks, Cable Markers and Wire Labels for Harness Identification, Terminal Blocks and DIN Rail Mounted Connectors, Kitting Service for Harness and Panel Builds.