Contact Us
  • Home
  • COMPONENTS
  • Flexible Conduit and Fittings for Panel and Machine Wiring

Flexible Conduit and Fittings for Panel and Machine Wiring

Galvanised steel flexible conduit in six sizes from 16 to 50 mm with stated outside diameter, inside diameter and bend radius. Overbraided steel conduit for runs that rub on a moving arm. Adaptalok ATS straight fittings in M20 and M25, IP66 as standard and IP69K with the ALS seal. Nylon fine pitch conduit for tight runs inside a cabinet.
quote now

Product Specifications

Product Overview

Flexible conduit does one job in a cabinet: it carries a cable from the gland plate to a door, a hinge column or a moving slide without letting the bundle rub on sheet metal or take the full bend at a terminal. Panel runs are short and the space is tight, so the wall of the tube and the bend radius matter more than the pull strength printed on the box.

Two systems cover machine and panel work. Galvanised steel flexible conduit is strip wound and takes heat, swarf and hot chips, which is why it sits around a spindle, a welder or a heater bank. Nylon conduit is lighter and non-metallic, so it is used where a metal raceway is not wanted or where the run has to follow a tight radius behind a DIN rail.

The conduit and the fitting are one assembly. A 20 mm conduit with a fitting that only reaches IP40 lets coolant in at the first wash, and a fitting with the wrong thread will not seat in a metric knockout without an adapter. Size, then thread, then seal: that is the order that avoids a second order.

Key Specifications

SystemNominal sizeOutside diameterInside diameterBend radiusNotes
Galvanised steel flexible conduit, S series16, 20, 25, 32, 40, 50 mm16.0 to 53.0 mm13.0 to 48.4 mm35 to 90 mm static10, 25 or 50 m coil
Overbraided steel conduit, SPLHCB type16 to 50 mmsteel core with rubber coverstainless steel overbraidmedium flexibilityfor abrasion and hot spots
Adaptalok ATS straight fitting, type A16, 21 and 25 mmM20 x 1.5 or M25 x 1.5conduit entrysingle piece, locknut suppliedIP66 standard, IP69K with ALS seal
Nylon conduit, PAFS fine pitch10 mm10.0 mm6.5 mm15 mm50 m coil

Included Models and Order Codes

The steel conduit codes below carry the coil length after the slash, so S25/25M is a 25 mm conduit in a 25 m coil. Sizes and diameters are taken from the maker table, and the bend radius is the static figure: a run that moves needs a larger radius than the table shows.

Part numberNominal sizeOutside diameterInside diameterStatic bend radiusCoil length
S16/10M16 mm16.0 mm13.0 mm35 mm10 m
S20/10M20 mm20.5 mm16.9 mm45 mm10 m
S25/25M25 mm25.0 mm21.4 mm55 mm25 m
S32/25M32 mm32.0 mm28.1 mm60 mm25 m
S40/25M40 mm42.5 mm37.7 mm80 mm25 m
S50/10M50 mm53.0 mm48.4 mm90 mm10 m

Fittings and Threads That Match the Conduit

A conduit order is only complete with the fittings. The three below cover the common panel entry: a metric knockout at 20 or 25 mm, and a 1/2 in entry on an older enclosure. The ALS seal is a separate item and is the part that lifts the assembly from IP66 to IP69K.

Part numberConduit sizeThreadProtectionBody
AT16/M20/A16 mmM20 x 1.5IP66 standard, IP67 and IP68 with ALS sealPA66, black or grey
AT21/M20/A21 mmM20 x 1.5IP66 standard, IP69K with ALS sealPA66, black or grey
7TCA296000R079725 mm Adaptalok straightM25 x 1.5IP66polyamide, black
AT16/PF050/A16 mm1/2 inIP66 standard, IP68 with ALS sealPA66, black or grey

Key Features

Bend radius stated per size – 35 mm at 16 mm conduit and 90 mm at 50 mm, so the route can be planned before the cable is pulled and the tube is not flattened at the first corner.

Seal decides the IP rating – Adaptalok ATS is IP66 as standard and reaches IP67, IP68 and IP69K with the ALS seal, which is the difference between a dry cabinet and a wash-down line.

Six sizes in one family – 16, 20, 25, 32, 40 and 50 mm nominal, with 10, 25 and 50 m coils so a short panel run does not leave most of a drum on the floor.

Overbraided option – the SPLHCB type puts a stainless overbraid over a rubber covered steel core, for a run that rubs against a moving arm or a lift chain.

Metric, PG and 1/2 in threads – an existing enclosure with an older knockout does not need a punch and a new plate just to take a conduit.

Single piece fitting – the straight fitting is moulded in one part with a locknut, self-extinguishing and low smoke, which keeps the bill of materials and the fitting time short.

Applications

Conduit is chosen by what the run has to survive, not by the cabinet size. Three patterns repeat.

Machine tools and welding cells – steel conduit around the spindle and the coolant lines, with an overbraided length where the cable follows a moving arm.

Outdoor telecom and traffic cabinets – nylon conduit inside the cabinet, with an IP68 fitting at the gland plate so water running down the outside of the tube stops at the wall.

Medical and laboratory equipment – non-metallic conduit on a moving column, because the run has to flex thousands of times and a metal strip tube work hardens at the bend.

Conduit, trim, plinth and interlock parts are quoted together with the panel they belong to, and the SUPERB PCBA and the SUPERB PCB are checked against the same enclosure schedule so the cut-outs, the threads and the door swing all agree before the cabinet is built.

Sourcing and Cross-Reference

Size on the outside diameter, not on the trade name. A 20 mm conduit measures 20.5 mm outside and 16.9 mm inside, so a bundle that measures 17 mm will not pass. Add the cable diameter, not the conductor size, and leave about 30 percent fill before the pull becomes a fight.

Decide the IP rating before the fitting. The same conduit reaches IP66 with a standard Adaptalok and IP69K with the ALS seal, and the seal is a separate line on the order. A wash-down cabinet that is quoted without it comes back as a leak claim.

Keep the conduit run and the cable entry plate as two decisions. A brush plate at the cabinet base and a sealed conduit entry at the door serve different purposes, and mixing them usually means the plate is ordered twice. See lead time and availability when the conduit and the fittings have to ship together.

Check the pull before the second fix. A 25 m coil pulled through four 90 degree bends needs a draw wire and a second pair of hands; a run planned with two 45 degree bends can be pushed by one person.

The SUPERB Assembly team fits the conduit and the edge trim after the plates are painted, because a trim strip fitted before painting lifts at the corner and a conduit run fixed before painting traps overspray inside the tube.

Q: Can you supply the conduit with the fittings, locknuts and seals as one matched set?

A: Yes. Send the enclosure drawing or the cut-out list with the sheet thickness and the cable diameter; the SUPERB Tech team returns the conduit size, the fitting thread and the trim profile that fit the opening.

Why Builders Buy Conduit and Fittings From SUPERB

  1. Conduit and fitting quoted together: the size, the thread and the seal are checked against the same cut-out list, so the parts that arrive fit each other.
  2. Diameter and bend radius in the quote: the outside diameter, inside diameter and static bend radius are stated per size, not summarised as a nominal figure.
  3. IP66 and IP69K options: the ALS seal is quoted where the cabinet is washed down, and left out where it is not needed.
  4. Short coils for panel work: 10 m and 25 m coils are available, so a repair or a prototype does not need a full drum.

Related Product Families