Split Loom Conduit and Cable Sleeves for Harness Routing
Product Specifications
Product Overview
A harness that runs through a metal chassis rubs against every edge it passes. The damage is slow and invisible, and it shows up as an intermittent short after the cabinet has been in service for a year, usually at the point where the bundle crosses a folded lip.
Split loom is the cheapest fix and the one that does not require re-termination. The tubing is corrugated for flexibility and slit along its length, so it opens, wraps around an existing bundle and closes again. A bundle that was built and tested last week can be protected in place.
Material decides the temperature and the fire story. Polyethylene covers -40 C to +50 C and is the general indoor choice. Nylon covers -40 C to +110 C, which is what a harness near a heatsink or a lamp housing needs. Flame retardant nylon grades add a UL94 V-2 rating, and the UV resistant version of the same part adds stability for outdoor runs.
Sizing is by bundle diameter, not by cable count. The tubing inside diameter has to be larger than the bundle, and the corrugation allows a bundle about 10 to 15 percent wider than the nominal figure to be pulled in. A 10 mm inside diameter tube takes a bundle of roughly 9 mm, and a bundle that is forced in loses the flexibility the corrugation was there to provide.
Key Specifications
| Parameter | Polyethylene | Nylon | Flame retardant nylon |
|---|---|---|---|
| Temperature range | -40 C to +50 C | -40 C to +110 C | -40 C to +110 C |
| Flammability | Not rated | Not rated as standard | UL94 V-2 |
| UV stability | Indoor use | Indoor use | UV resistant version available |
| Wall | Slit corrugated, solid wall also available | Slit corrugated | Slit corrugated |
| Inside diameter | 7 mm to 47 mm | 7 mm to 28 mm | 6.5 mm to 48 mm |
| Colours | Black, orange, yellow | Black | Black |
| Reel lengths | 10 ft to 200 ft depending on size | 100 ft standard | 25 m to 900 m depending on size |
| Installation | Slit wall, opens along the length | Slit wall | Slit wall |
| Clamps | Loom clamps in the matching size | Loom clamps in the matching size | Loom clamps in the matching size |
Included Models and Order Codes
The table lists the common reel sizes with the inside and outside diameter, because the outside diameter is what decides whether the bundle still fits the duct or the clamp. Polyethylene parts carry an F in the part number and nylon parts carry an N. The suffix after the dash is colour and package: C20 is black 100 ft, C3 orange, C4 yellow.
| Part Number | Material | Inside dia (mm) | Outside dia (mm) | Reel | Colour |
|---|---|---|---|---|---|
| CLT25F-C20 | Polyethylene | 7.0 | 10.1 | 100 ft | Black |
| CLT38F-C20 | Polyethylene | 10.0 | 13.3 | 100 ft | Black |
| CLT50F-C20 | Polyethylene | 13.0 | 16.6 | 100 ft | Black |
| CLT62F-C20 | Polyethylene | 17.0 | 21.1 | 100 ft | Black |
| CLT75F-C20 | Polyethylene | 19.5 | 23.9 | 100 ft | Black |
| CLT100F-C20 | Polyethylene | 23.2 | 28.0 | 100 ft | Black |
| CLT125F-L20 | Polyethylene | 32.5 | 39.0 | 50 ft | Black |
| CLT150F-T20 | Polyethylene | 40.0 | 47.0 | 200 ft | Black |
| CLT188F-X20 | Polyethylene | 47.0 | 55.7 | 10 ft | Black |
| CLT25N-C630 | Nylon | 7.0 | 10.1 | 100 ft | Black |
| CLT38N-C630 | Nylon | 10.0 | 13.3 | 100 ft | Black |
| CLT50N-C630 | Nylon | 13.0 | 16.6 | 100 ft | Black |
| CLT75N-C630 | Nylon | 19.5 | 23.9 | 100 ft | Black |
| CLT100N-C630 | Nylon | 23.2 | 28.0 | 100 ft | Black |
Flame Retardant and UV Resistant Grades
The flame retardant parts use the same corrugation and the same slit, with a UL94 V-2 rating and a nylon body that holds to 110 C. The UV resistant version carries UV in the suffix and is the one for a run that leaves the cabinet and goes up a mast or along a wall. Sizes above 36 mm are supplied on shorter reels, so a long outdoor run is quoted by the metre rather than by the reel.
| Part Number | Inside dia (mm) | Outside dia (mm) | Length | Rating |
|---|---|---|---|---|
| CLT25NFR-3 | 6.5 | 10.0 | 900 m | UL94 V-2 |
| CLT38NFR-3 | 10.0 | 13.0 | 540 m | UL94 V-2 |
| CLT50NFR-3 | 12.0 | 15.8 | 320 m | UL94 V-2 |
| CLT62NFR-3 | 17.0 | 21.2 | 200 m | UL94 V-2 |
| CLT75NFR-3 | 20.0 | 25.0 | 118 m | UL94 V-2 |
| CLT100NFR-3 | 29.0 | 34.5 | 56 m | UL94 V-2 |
| CLT125NFR-3 | 36.0 | 42.5 | 32 m | UL94 V-2 |
| CLT150NFR-3 | 48.0 | 54.5 | 25 m | UL94 V-2 |
Key Features
Slit wall for retrofits – The tube opens along its whole length, so a harness that is already terminated can be wrapped without pulling a single contact.
Corrugation for tight bends – The ribs allow a bend radius that a smooth tube of the same wall cannot follow, which is what a door hinge or a cable chain needs.
Three materials for three temperatures – Polyethylene to 50 C, nylon to 110 C and flame retardant nylon with a UL94 V-2 rating for the runs that a safety reviewer will ask about.
Inside diameter from 7 mm to 47 mm – Nine polyethylene sizes and five nylon sizes cover a single signal pair up to a 47 mm power bundle.
Outside diameter on the sheet – The outside figure is what decides whether the wrapped bundle still passes a clamp or a duct, so both diameters are listed.
Colour as a marker – Orange and yellow reels let a high voltage or a safety circuit be identified at a glance without a label.
Reels cut to length – A 100 ft reel suits a cabinet shop, and a long outdoor run is quoted by the metre from the manufacturing reel.
Clamps and ties in the same range – Loom clamps and cable ties are ordered with the tubing, so the bundle is fixed at the same spacing as the rest of the harness.
Applications
Split loom is used on any bundle that has to be protected after it was built. The four cases below are the ones that come up most often in panel and equipment work.
Panel and cabinet wiring – A bundle that crosses a folded chassis edge gets a 10 mm tube, and the tube is clamped at 300 mm intervals so it does not sag into a terminal.
Automotive and vehicle harness – Nylon holds to 110 C near an engine bay or a lamp, and the slit wall lets a branch be added without cutting the main run.
Machine retrofit and repair – An existing harness is wrapped in place, which avoids re-terminating a connector that is potted or crimped at the maker end.
Outdoor and mast runs – The UV resistant flame retardant grade is used where the bundle leaves the cabinet and runs along a wall or a pole.
Loom tubing is specified on the SUPERB PCB harness drawing by bundle diameter and by the temperature at the hottest point, because a 50 C polyethylene tube placed next to a 70 C heatsink fails inside a year. On the SUPERB PCBA route the tubing is cut and fitted on the bench, before the harness goes into the cabinet.
Sourcing and Cross-Reference
Loom tubing is bought by the reel and consumed by the metre, so the reel length matters as much as the diameter. A 47 mm tube comes on a 10 ft reel because the coil gets stiff, while a 7 mm tube comes on 100 ft. Ordering a large size by the reel and a small size by the metre is normal in the same project.
The second decision is temperature. Polyethylene is cheaper and more flexible, and it is the right answer inside a cabinet that never exceeds 50 C. Nylon costs more and holds to 110 C, which is what a run near a heatsink, a lamp or an engine needs. The flame retardant grade is a nylon part with a UL94 V-2 rating and a UV option.
Colour is a working aid rather than a specification. Orange and yellow are used to mark a high voltage or a safety circuit, and black is the default. The tubing is slit, so a length can be added or removed without disturbing the bundle, which is why a service kit usually holds one reel of each common size.
SUPERB Assembly wraps the slit around the bundle without twisting it, clamps at the spacing on the drawing and leaves 10 mm of tube past the last branch, because a tube that ends on a bend wears through at the edge.
Q: Do you supply CLT38N in the flame retardant UV resistant grade, cut to 30 m lengths, with the matching loom clamps?
A: Send the bundle diameter, the highest temperature on the run, whether the harness is already terminated and the length needed. The SUPERB Tech desk replies with the material, the size and the reel or cut length, plus the clamps that match the outside diameter.
Why Buy Loom Tubing Through SUPERB
- Diameter matched to the bundle: The inside diameter and the bundle size are compared before the reel is quoted, because a tube that is forced on loses its bend radius.
- Material matched to the temperature: Polyethylene, nylon and flame retardant nylon are quoted against the temperature at the hottest point of the run, not the ambient of the room.
- Reels and cut lengths on one line: A cabinet shop takes the 100 ft reel, and a field repair takes a cut length with clamps, from the same part number.
- Flame retardant grade available: UL94 V-2 nylon with a UV option for the runs that leave the cabinet, so a safety review does not stop the build.
- Harness assembly support: The assembly team wraps and clamps the bundle to the drawing, marks the branch points and checks that no tube ends inside a bend.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Braided Sleeving and Expandable Sleeves for Harness Protection, Heat Shrink Tubing and Sleeves for Harness Protection, Cable Clamps and Harness Ties for Internal Wiring, Cable Glands and Strain Relief Bushings for Enclosure Entries, Cable Markers and Wire Labels for Harness Identification, Kitting Service for Harness and Panel Builds.