Contact Us

Enclosure Plinths and Base Panels

Base and plinth corner pieces in 100 mm and 200 mm heights for 300 to 1800 mm wide cabinets. Side trim panels, vented panels and brush strip panels for cable entry at the base. Sheet steel in RAL 9005, with a stainless option for wash-down areas. Corner pieces self-position on the baying system, so a bay of cabinets lines up.
quote now

Product Specifications

Product Overview

A plinth is the part of a floor standing cabinet that lifts the enclosure off the floor and closes the gap under the door. It does three jobs at once: it keeps a fork lift and a mop away from the door seal, it gives the cabinet a level base on an uneven floor, and it provides the route for cables entering from below.

The system is built from corner pieces and trim panels rather than a single welded frame. Four corner pieces carry the load, and the trim panels close the front, the rear and the sides. Because the corner pieces are symmetrical and self-positioning, a bay of two or three cabinets shares one continuous plinth line, which is the reason a bayed suite looks like one unit and not three.

Height and width are the two figures that have to be right. A 100 mm plinth on a 2000 mm cabinet puts the door at 1900 mm, which is the number the operator actually reaches. Width is taken per cabinet and the side panels are taken per depth, so a 600 mm wide by 600 mm deep cabinet needs one front and rear set and one pair of side panels, not four of the same part.

Key Specifications

ItemHeightWidth rangeMaterialFinishPack
Base and plinth corner pieces, front and rear panels100 mm300 to 1800 mmsheet steelRAL 90052 sets per pack
Base and plinth corner pieces, front and rear panels200 mm300 to 1800 mmsheet steelRAL 90052 sets per pack
Side trim panels100 mm300 to 1200 mm depthsheet steelRAL 90052 panels per pack
Side trim panels, stainless100 and 200 mm400 to 600 mm depthstainless 1.4301brushed2 panels per pack
Vented trim panels100 mm600, 800 and 1000 mmsheet steelRAL 90051 panel

Included Models and Order Codes

The corner piece code carries the cabinet width, so a 600 mm wide cabinet takes 8620.002. The 200 mm high family uses the same widths with a different code block. Side panels are ordered by depth and are separate parts, which is where most short orders come from.

Part numberHeightFits widthPackWeight
8620.000100 mm300 mm2 sets2.73 kg per pack
8620.001100 mm400 mm2 setson request
8620.002100 mm600 mm2 setson request
8620.003100 mm800 mm2 setson request
8620.004100 mm850 mm2 setson request
8620.005100 mm1000 mm2 setson request
8620.020200 mm300 mm2 setson request
8620.030100 mm side panel300 mm depth2 panelson request
8620.033100 mm side panel600 mm depth2 panelson request
8620.092100 mm vented600 mm1 panelon request

Key Features

Two heights – 100 mm for a normal floor standing cabinet and 200 mm for a cable route under the base or a cabinet on an uneven floor.

Widths from 300 to 1800 mm – the corner piece code follows the cabinet width, so the front and rear panels are cut to the bay and not to a standard length.

Symmetrical corner pieces – a bay of cabinets shares one plinth line without an adapter between the units.

Vented and brush strip panels – air can move under the cabinet and cables can enter from below without a separate plate being punched.

Stainless option – 1.4301 side panels with a brushed finish, for a wash-down area where painted steel at floor level rusts first.

Fits the levelling feet – the corner pieces accept the standard levelling foot, so the cabinet is levelled through the plinth rather than on packers.

Applications

The plinth is chosen on the floor and on the cable route, not on the cabinet. Three patterns.

Bayed switchgear and drive cabinets – one continuous plinth under three or four bays, with the side panels only at the two ends of the suite.

Cabinets in a wash-down area – a stainless side panel set and a 100 mm plinth, so the base can be hosed without the paint lifting at the floor line.

Cabinets fed from below – a brush strip trim panel at the base, so the cables come up into the cabinet without a separate gland plate and without a draught.

Conduit, trim, plinth and interlock parts are quoted together with the panel they belong to, and the SUPERB PCBA and the SUPERB PCB are checked against the same enclosure schedule so the cut-outs, the threads and the door swing all agree before the cabinet is built.

Sourcing and Cross-Reference

Order the side panels with the front and rear set. The corner piece packs contain the front and rear trim; the sides are separate parts and are the line that gets missed. A bay of two cabinets needs side panels at the two outer ends only.

Take the height from the working height, not from the floor. A 100 mm plinth is normal; a 200 mm plinth is for a cable route or a very uneven floor. On a 2000 mm cabinet the extra 100 mm is visible at the door.

Leave the levelling feet in the order. The corner piece accepts the standard foot, and a cabinet levelled on timber packers moves the first time a door is slammed. See lead time and availability when the plinth, the feet and the cabinet are on one delivery.

Check the floor before the finish. A painted plinth in a wet room rusts at the floor line first; the stainless side panel is the part that pays for itself there.

The SUPERB Assembly team fits the conduit and the edge trim after the plates are painted, because a trim strip fitted before painting lifts at the corner and a conduit run fixed before painting traps overspray inside the tube.

Q: Do the corner pieces include the side trim panels as well as the front and rear?

A: Yes. Send the enclosure drawing or the cut-out list with the sheet thickness and the cable diameter; the SUPERB Tech team returns the conduit size, the fitting thread and the trim profile that fit the opening.

Why Builders Buy Plinths and Base Panels From SUPERB

  1. Height and width checked against the cabinet: the code is matched to the cabinet width and the door height, so the plinth does not change the working height unexpectedly.
  2. Front, rear and side listed separately: the quote shows which parts are in the pack and which are separate, so a bay is not ordered short.
  3. Vented and brush strip options: cable entry and airflow at the base are handled by a trim panel rather than a punched plate.
  4. Stainless where it is needed: side panels in 1.4301 for wash-down areas, painted steel elsewhere.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Levelling Feet and Castors, Cable Entry Plates and Brush Grommets, Busbars and Earth Bars, Steel and Aluminium DIN Rails.