Levelling Feet and Castors for Floor Standing Enclosures
Product Specifications
Product Overview
A floor standing enclosure meets the floor in one of two ways: on feet that carry the weight and allow the cabinet to be levelled, or on castors that let it move and then be locked. The choice is made before the base is ordered, because the thread in the base and the clearance under the plinth are different.
Feet are rated per component, not per set. A 4612.000 foot carries 3000 N static, so four of them carry 12 kN in theory, but the enclosure frame and the floor are usually the limit before the feet are. The heavier 2859.000 carries 350 kg per foot and has 15 mm of compensation, which is the part for a cabinet that sits on an uneven screed and has to be levelled after it is loaded.
Castors are rated per castor and by clearance. The 4611.000 set gives 40 kg per castor with 50 mm clearance, the 6148.000 gives 75 kg with 85 mm, and the 7495.000 gives 120 kg with 125 mm. A taller castor is not only stronger: it lifts the cabinet so a pallet truck can get under it, and it rolls over a threshold that a 50 mm wheel will not.
Key Specifications
| Model | Type | Thread | Height range or clearance | Static load | Material |
|---|---|---|---|---|---|
| 4612.000 | Levelling foot | M12 x 40 | 18 - 43 mm | 3000 N per foot | Carbon steel |
| 2859.000 | Levelling foot | M12 | 85 - 115 mm, 15 mm compensation | 350 kg per foot | Brass nickel plated, stainless bolts |
| 7507.740 | Levelling foot | M10 x 20 | 10 - 20 mm | 5500 N per foot | Metal and plastic |
| 4611.000 | Twin castor set | M12 x 20 | 50 mm | 40 kg per castor | Black, 4 pcs |
| 6148.000 | Twin castor set | M12 x 20 | 85 mm | 75 kg per castor | Black, grey running surface |
| 7495.000 | Twin castor set | M12 | 125 mm | 120 kg per castor | Black |
| 8660.110 | Transport castor, base mounted | - | - | 3000 N dynamic with 4 castors | Steel |
Included Models and Order Codes
The pack quantity is part of the order code, and the lock arrangement is part of the castor set: the twin sets ship with two castors locked and two free, so the cabinet can be steered rather than dragged.
| Part number | Description | Pack | Lock | Notes |
|---|---|---|---|---|
| 4612.000 | Levelling foot M12 x 40 | 4 pcs | - | Base/plinth adaptor needed on VX |
| 2859.000 | Levelling foot, 85 - 115 mm | 4 pcs | - | Brass foot, stainless bolt |
| 7507.740 | Levelling foot M10 x 20 for FlatBox | 4 pcs | - | Hex socket 30 mm |
| 4611.000 | Twin castor set, 50 mm | 1 set of 4 | 2 with lock | 40 kg per castor |
| 6148.000 | Twin castor set, 85 mm | 4 pcs | 2 with lock | 75 kg per castor |
| 7495.000 | Twin castor set, 125 mm | 4 pcs | 2 with lock | 120 kg per castor |
| 8660.110 | Transport castor for base/plinth | 1 pc | - | 3000 N dynamic with 4 castors |
| 8800.290 | Base/plinth adaptor for twin castors | 1 pc | - | For TS base/plinth |
Load Rules for Feet and Castors
Load ratings are per component and assume a level floor and a static load unless stated otherwise. The table shows how the total changes with the number of supports and with movement.
| Configuration | Supports | Rated total | Note |
|---|---|---|---|
| 4612.000 on a VX25 base | 4 feet | 3000 N per foot | Static load, level floor |
| 2859.000 on a TS base | 4 feet | 350 kg per foot | 15 mm compensation for uneven floors |
| 7507.740 on a FlatBox | 4 feet | 5500 N per foot | Small enclosure, M10 thread |
| 8660.110, single enclosure | 4 castors | 3000 N dynamic total | Movement, not static only |
| 8660.110, bayed enclosures | 6 castors | 1500 N per enclosure | Load shared across the bay |
| Twin castor set, 120 kg | 4 castors | 480 kg total | Static rating per castor, check the floor |
Key Features
Rating per component – the load is stated per foot or per castor, so the total is a calculation rather than a guess.
Adjustment range stated – 18 to 43 mm, 10 to 20 mm and 85 to 115 mm, with 15 mm of compensation on the heavy foot.
Thread matched to the base – M10 x 20, M12 x 20 and M12 x 40 cover the common base and plinth systems.
Castor clearance by duty – 50, 85 and 125 mm wheels, so the cabinet can clear a threshold or a pallet truck.
Two castors locked per set – the set steers and then locks, which is what a cabinet on a production floor needs.
Adaptors quoted with the set – the base and plinth adaptor is ordered with the castors, not after the base arrives.
Applications
Feet and castors follow the floor and the maintenance plan. Three patterns repeat.
Machine and drive cabinets – levelling feet on a concrete floor, with the cabinet levelled after the drives are fitted.
Test and laboratory racks – castor sets where the rack is moved between benches and locked in place for a test.
Outdoor and skid mounted panels – transport castors on the base, used for positioning only and removed before the panel is bolted down.
Feet and castors are quoted with the enclosure and the base, and the SUPERB PCBA and the SUPERB PCB are checked against the same floor plan so the plinth and the castor set arrive together.
Sourcing and Cross-Reference
Decide feet or castors before the base is ordered. The thread and the clearance differ, and a castor set cannot be fitted to a base that was drilled for feet without an adaptor.
Add the weight of the doors and the roof to the enclosure weight before choosing the castor. A 120 kg per castor set is 480 kg in total, which a loaded drive cabinet can reach.
Check the floor, not only the load. A 50 mm castor will not cross a 20 mm expansion joint, and a levelling foot on a sloped floor runs out of adjustment before the cabinet is level.
Keep the adaptor in the same order. The base and plinth adaptor is a separate part number and is the item that stops the installation on the day. See lead time and availability for mixed base and castor orders.
The SUPERB Assembly team fits the feet before the enclosure is loaded, since the threaded insert is reached from below and the weight has to be off the base.
Q: How many castors does a bayed enclosure need?
A: Yes. Send the enclosure size and the floor condition; the SUPERB Tech team quotes the feet or the castor set with the matching base adaptor.
Why Builders Buy Enclosure Feet and Castors From SUPERB
- Load stated per part: the rating is per foot or per castor, with the static and dynamic cases kept apart.
- Thread matched to the base: the foot or castor is picked by the base thread, so no adaptor is discovered missing on site.
- Adaptors in the same quote: base and plinth adaptors ship with the castor set.
- Lock arrangement stated: two castors locked and two free, so the cabinet steers and then stays put.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Rubber Bumpers and Feet, Enclosure Handles and Corner Guards, Cam Locks and Key Locking Latches, Component Lead Time Solutions.