Levelling feet with 10 to 115 mm adjustment and 3000 to 5500 N static load. Twin castor sets rated 40, 75 and 120 kg per castor. Threads M10 x 20, M12 x 20 and M12 x 40 for the common base systems. Base and plinth adaptors quoted with the feet or the castor set.
quote now

Product Specifications

Product Overview

A floor standing enclosure meets the floor in one of two ways: on feet that carry the weight and allow the cabinet to be levelled, or on castors that let it move and then be locked. The choice is made before the base is ordered, because the thread in the base and the clearance under the plinth are different.

Feet are rated per component, not per set. A 4612.000 foot carries 3000 N static, so four of them carry 12 kN in theory, but the enclosure frame and the floor are usually the limit before the feet are. The heavier 2859.000 carries 350 kg per foot and has 15 mm of compensation, which is the part for a cabinet that sits on an uneven screed and has to be levelled after it is loaded.

Castors are rated per castor and by clearance. The 4611.000 set gives 40 kg per castor with 50 mm clearance, the 6148.000 gives 75 kg with 85 mm, and the 7495.000 gives 120 kg with 125 mm. A taller castor is not only stronger: it lifts the cabinet so a pallet truck can get under it, and it rolls over a threshold that a 50 mm wheel will not.

Key Specifications

ModelTypeThreadHeight range or clearanceStatic loadMaterial
4612.000Levelling footM12 x 4018 - 43 mm3000 N per footCarbon steel
2859.000Levelling footM1285 - 115 mm, 15 mm compensation350 kg per footBrass nickel plated, stainless bolts
7507.740Levelling footM10 x 2010 - 20 mm5500 N per footMetal and plastic
4611.000Twin castor setM12 x 2050 mm40 kg per castorBlack, 4 pcs
6148.000Twin castor setM12 x 2085 mm75 kg per castorBlack, grey running surface
7495.000Twin castor setM12125 mm120 kg per castorBlack
8660.110Transport castor, base mounted--3000 N dynamic with 4 castorsSteel

Included Models and Order Codes

The pack quantity is part of the order code, and the lock arrangement is part of the castor set: the twin sets ship with two castors locked and two free, so the cabinet can be steered rather than dragged.

Part numberDescriptionPackLockNotes
4612.000Levelling foot M12 x 404 pcs-Base/plinth adaptor needed on VX
2859.000Levelling foot, 85 - 115 mm4 pcs-Brass foot, stainless bolt
7507.740Levelling foot M10 x 20 for FlatBox4 pcs-Hex socket 30 mm
4611.000Twin castor set, 50 mm1 set of 42 with lock40 kg per castor
6148.000Twin castor set, 85 mm4 pcs2 with lock75 kg per castor
7495.000Twin castor set, 125 mm4 pcs2 with lock120 kg per castor
8660.110Transport castor for base/plinth1 pc-3000 N dynamic with 4 castors
8800.290Base/plinth adaptor for twin castors1 pc-For TS base/plinth

Load Rules for Feet and Castors

Load ratings are per component and assume a level floor and a static load unless stated otherwise. The table shows how the total changes with the number of supports and with movement.

ConfigurationSupportsRated totalNote
4612.000 on a VX25 base4 feet3000 N per footStatic load, level floor
2859.000 on a TS base4 feet350 kg per foot15 mm compensation for uneven floors
7507.740 on a FlatBox4 feet5500 N per footSmall enclosure, M10 thread
8660.110, single enclosure4 castors3000 N dynamic totalMovement, not static only
8660.110, bayed enclosures6 castors1500 N per enclosureLoad shared across the bay
Twin castor set, 120 kg4 castors480 kg totalStatic rating per castor, check the floor

Key Features

Rating per component – the load is stated per foot or per castor, so the total is a calculation rather than a guess.

Adjustment range stated – 18 to 43 mm, 10 to 20 mm and 85 to 115 mm, with 15 mm of compensation on the heavy foot.

Thread matched to the base – M10 x 20, M12 x 20 and M12 x 40 cover the common base and plinth systems.

Castor clearance by duty – 50, 85 and 125 mm wheels, so the cabinet can clear a threshold or a pallet truck.

Two castors locked per set – the set steers and then locks, which is what a cabinet on a production floor needs.

Adaptors quoted with the set – the base and plinth adaptor is ordered with the castors, not after the base arrives.

Applications

Feet and castors follow the floor and the maintenance plan. Three patterns repeat.

Machine and drive cabinets – levelling feet on a concrete floor, with the cabinet levelled after the drives are fitted.

Test and laboratory racks – castor sets where the rack is moved between benches and locked in place for a test.

Outdoor and skid mounted panels – transport castors on the base, used for positioning only and removed before the panel is bolted down.

Feet and castors are quoted with the enclosure and the base, and the SUPERB PCBA and the SUPERB PCB are checked against the same floor plan so the plinth and the castor set arrive together.

Sourcing and Cross-Reference

Decide feet or castors before the base is ordered. The thread and the clearance differ, and a castor set cannot be fitted to a base that was drilled for feet without an adaptor.

Add the weight of the doors and the roof to the enclosure weight before choosing the castor. A 120 kg per castor set is 480 kg in total, which a loaded drive cabinet can reach.

Check the floor, not only the load. A 50 mm castor will not cross a 20 mm expansion joint, and a levelling foot on a sloped floor runs out of adjustment before the cabinet is level.

Keep the adaptor in the same order. The base and plinth adaptor is a separate part number and is the item that stops the installation on the day. See lead time and availability for mixed base and castor orders.

The SUPERB Assembly team fits the feet before the enclosure is loaded, since the threaded insert is reached from below and the weight has to be off the base.

Q: How many castors does a bayed enclosure need?

A: Yes. Send the enclosure size and the floor condition; the SUPERB Tech team quotes the feet or the castor set with the matching base adaptor.

Why Builders Buy Enclosure Feet and Castors From SUPERB

  1. Load stated per part: the rating is per foot or per castor, with the static and dynamic cases kept apart.
  2. Thread matched to the base: the foot or castor is picked by the base thread, so no adaptor is discovered missing on site.
  3. Adaptors in the same quote: base and plinth adaptors ship with the castor set.
  4. Lock arrangement stated: two castors locked and two free, so the cabinet steers and then stays put.