Dust Caps and Connector Covers for Unused Ports
Product Specifications
Product Overview
An unused port on a cabinet is an open hole with five or eight contacts at the bottom of it. Dust settles on the contacts, wash water runs in, and swarf from a drilling job a metre away finds the thread. The failure shows up months later as an intermittent channel that nobody can reproduce on the bench.
A dust cap closes the port to the same IP rating as the connector. The cap is a moulded shell with an internal thread or a push fit, a seal that lands on the connector face and a strap that keeps the cap attached to the cable or the panel so it is not lost when the port is in use.
The range covers the two interfaces that turn up on industrial cabinets. The M12 family covers A, B, D, K, L, S, T, US and X coded connectors, with a cap for a male cable end, a female cable end, a male panel socket and a female panel socket. The RD24 cap covers the 692 and 693 series circular connectors, which are used on larger sensor and power ports.
IP67 is the rating that matters, and it only holds with the cap fully seated on a clean connector face. A cap that is cross threaded or a face with a grain of grit under the seal is an IP44 joint with a good label on it. The strap is part of the same moulding, so the cap stays with the port instead of going into a pocket.
Key Specifications
| Parameter | Value | Notes |
|---|---|---|
| Protection | IP67 with the cap seated | Rating applies to the mated pair |
| Temperature range | -40 C to +85 C | Cap and seal |
| Cap material | PA66, PBT or PA depending on the part | See the model table |
| Strap material | PUR | Moulded to the cap |
| Seal | Neoprene on the cable end caps | Compressed against the connector face |
| Thread | M12 x 1, or RD24 locking system | Coded caps fit the matching code |
| Colours | Black | Standard |
| Mounting | Screwed on, or snapped over the flange | Front fastened versions for a panel socket |
| Strap | PUR, moulded to the cap | Keeps the cap on the port |
Included Models and Order Codes
The part number says which connector the cap closes. A cap for a cable connector goes on the free end of a lead; a cap for a panel connector goes on the socket in the cabinet wall; a front fastened cap goes on a receptacle that is mounted from the front of the plate. The code after M12 tells which keying the cap fits, and a cap for an A coded connector does not seat on an X coded one.
| Part Number | Fits | Protection | Cap material | Temperature |
|---|---|---|---|---|
| 08 2424 010 000 | M12 male cable connector | IP67 | PBT, UL94 V-0 | -40 to +85 C |
| 08 2425 010 000 | M12 female cable connector | IP67 | - | -40 to +85 C |
| 08 2615 000 000 | M12 male panel mount connector | IP67 | - | -40 to +85 C |
| 08 2616 000 000 | M12 female panel mount connector | IP67 | - | -40 to +85 C |
| 08 2676 000 000 | M12 male panel connector, front fastened | IP67 | PA66, UL94 V-0 | -40 to +85 C |
| 08 2677 000 000 | M12 female panel connector, front fastened | IP67 | PA66, UL94 V-0 | -40 to +85 C |
| 08 2769 000 000 | M12 distribution box and socket | IP67 | PA | -40 to +85 C |
| 08 2991 000 000 | M12 female connector | IP67 | - | -40 to +85 C |
| 08 2989 000 000 | M12, measure A 11 mm | IP67 | - | -40 to +85 C |
| 08 2990 000 000 | M12, measure A 14.5 mm | IP67 | - | -40 to +85 C |
| 08 2299 000 000 | RD24, 692 and 693 series male cable connector | IP67 | - | -40 to +85 C |
Key Features
IP67 on an unused port – The cap seals on the connector face, so a port that is not in use has the same protection as a mated pair.
Caps for both genders – A male cable end, a female cable end, a male panel socket and a female panel socket each have their own part number.
Front fastened versions – A receptacle mounted from the front of a plate takes a cap that snaps over the flange instead of screwing into a thread.
Strap moulded to the cap – The cap stays attached to the cable or the panel when the port is in use, so it is not lost between services.
PA66 and PBT bodies – Both are UL94 V-0 mouldings, and the material is stated per part number rather than per family.
Temperature to 85 C – The cap and the neoprene seal hold from -40 C to +85 C, which covers an outdoor cabinet in summer and a cold store in winter.
Code specific fit – A, B, D, K, L, S, T, US and X coded M12 connectors each take the matching cap, so a cap cannot be forced onto the wrong keyway.
Low weight – 1.3 g to 4.8 g per cap, so a bag of spares does not load a harness or a door.
Applications
A cap is a small part that protects a port between builds, between services or for the life of the cabinet. The four cases below are the common ones.
Cabinet and machine builds – Ports that are wired later are capped at the end of the build, so dust from the site does not settle on the contacts.
Outdoor and washdown cabinets – A cap keeps wash water out of a socket that is only used during commissioning, and the strap keeps it on the cabinet after that.
Test and burn in racks – Unused ports on a rack panel are capped so a probe or a cable cannot short two contacts during a test run.
Spares and service kits – A bag of caps on the service van is cheaper than a connector replacement, and the part number is on the bag.
A cabinet leaves the shop with every unused port capped, and the SUPERB PCB panel drawing lists the caps by connector code so a later service fits the right one. On the SUPERB PCBA build the caps go on after the functional test, because a cap that is fitted before the test has to come off again.
Sourcing and Cross-Reference
A cap is quoted by the connector it fits, not by the thread alone. Two M12 caps with the same thread can have a different internal depth or a different keyway, and a cap that bottoms out on the contacts before the seal lands is not sealing at all.
The material is on the part number. A PBT body and a PA66 body look the same in a photo and behave differently at 85 C and in a chemical wash. Where the cabinet is cleaned with a solvent, the material and the seal are checked against the cleaning agent before the cap is released.
The strap is the feature that decides whether the cap is still there in a year. A cap without a strap is a cap that gets put down on a machine and lost, and the port is then open until the next service. Every part in this range has the strap moulded to the body.
SUPERB Assembly seats each cap by hand until the seal touches the face, checks the strap is on the cable and lists the caps on the shipping checklist, because a missing cap is an open IP67 port on a sealed cabinet.
Q: Can you supply the IP67 cap for an M12 female panel socket, front fastened, 20 pieces with the strap, for a washdown cabinet?
A: Send the connector series, the gender, whether it is a cable end or a panel socket and the code. The SUPERB Tech desk replies with the cap part number, the material and the temperature range, and confirms that the seal lands on the connector face.
Why Buy Connector Caps Through SUPERB
- Part number matched to the interface: The connector gender, the mounting style and the coding are confirmed before the cap is quoted, so the seal lands on the face.
- IP67 confirmed on the cap: The rating is stated for the cap seated on a clean face, which is the only condition where it holds.
- Material stated per part: PA66 and PBT bodies with UL94 V-0 are listed per part number, because the washdown chemical decides which one survives.
- Strap on every part: The cap stays with the port after it is opened, which is what keeps the port covered between services.
- Harness and panel support: The assembly team fits the caps at the end of the build and lists them on the shipping checklist, so no port leaves the shop open.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: RF Coaxial Connectors and Adapters, DIN and Circular Connectors for Panel Wiring, Cable Glands and Strain Relief Bushings for Enclosure Entries, Breather Vents and Pressure Equalization Plugs, Nylon Grommets and Hole Plugs for Panel Openings, Incoming Inspection Plan.