LoRa and Sub-GHz Transceiver Modules for Long Range Links
Product Specifications
Product Overview
A LoRa module is the radio half of a long range link. The chirp spread spectrum modulation trades data rate for sensitivity: at 62.5 kbps the link needs a strong signal, and at 0.018 kbps the receiver still decodes packets at -147 dBm, which is about 20 dB below what a narrowband FSK part manages. That 20 dB is worth roughly a factor of ten in free space range, and it is why a meter in a basement can reach a concentrator a few kilometres away on a few milliwatts.
The chipset generation matters more than the module brand. The SX1276 and SX1278 parts are the first generation, they cover 137 MHz to 1020 MHz in two versions, and they deliver up to +20 dBm with a receive current around 10 mA to 12 mA. The SX1262 and SX1268 parts are the second generation, they add a larger spreading factor range, a lower noise figure and a receive current of 6.8 mA on the E22-900M22S, and they bring the same +22 dBm output at a lower supply current. On a battery meter that difference is the difference between a five year and a ten year cell.
Output power and duty cycle are regulated together. A 30 dBm module such as the E22-900M30S reaches 12 km in the maker test, but a 30 dBm transmission is only legal in the 868 MHz band for a small fraction of the time, and the module needs a supply that can deliver the burst. A 22 dBm part reaches 6.5 km in the same test and is far easier to power from a lithium cell. The antenna and the enclosure usually matter more than the last 8 dB of output: a quarter wave whip mounted outside a metal box outperforms a 30 dBm part with an antenna inside it.
The interface decides the firmware work. A bare SPI module exposes the radio registers, so the host runs the driver, sets the spreading factor, the bandwidth and the coding rate, and handles the packet RAM. A UART module such as the E22-400T22S takes AT commands and does the framing itself, which shortens development but removes the fine control over the air time. Products that must interoperate with an existing LoRaWAN network usually need the SPI part and a certified stack; products that just need a private point to point link are faster with the UART part.
Supply range and current are the last check. The SX1262 modules run from 1.8 V to 3.7 V, so they work from a single lithium cell without a boost converter, and they draw 119 mA while transmitting at 22 dBm, 6.8 mA while receiving and about 2 microamps in sleep. The older SX1276 parts want a clean 3.3 V and draw more in receive, which matters on a solar node that spends most of its life listening.
The tables below list the modules we quote most often for meter reading, agriculture and industrial telemetry. Band, output power, sensitivity and interface come from the maker data sheet for each order code.
Key Specifications
| Parameter | E22-900M22S | E22-900M30S | E22-400T22S | RFM95W-868S2 | Ra-02 |
|---|---|---|---|---|---|
| Chipset | Semtech SX1262 with PA and LNA | Semtech SX1262 with PA and LNA | Semtech SX1268 with PA and LNA | Semtech SX1276 | Semtech SX1278 |
| Band | 850 MHz to 930 MHz, 868 and 915 centre | 868 MHz and 915 MHz | 430 MHz and 470 MHz | 868 MHz | 410 MHz to 525 MHz |
| Modulation | LoRa, FSK, GFSK | LoRa, FSK, GFSK | LoRa, FSK, GFSK | LoRa, FSK, GFSK, MSK, OOK | LoRa, FSK, GFSK, MSK, OOK |
| Maximum output | 22 dBm | 30 dBm | 22 dBm | 20 dBm | 20 dBm |
| Sensitivity | -147 dBm at 0.3 kbps | -147 dBm at 0.3 kbps | -147 dBm at 0.3 kbps | -139 dBm on the 868 module rating | -139 dBm |
| Air data rate | 0.018 kbps to 62.5 kbps LoRa, up to 300 kbps FSK | 0.018 kbps to 62.5 kbps LoRa | 0.018 kbps to 62.5 kbps LoRa | 0.018 kbps to 37.5 kbps LoRa | 0.018 kbps to 37.5 kbps LoRa |
| Supply voltage | 1.8 V to 3.7 V | 1.8 V to 3.7 V | 1.8 V to 3.7 V | 1.8 V to 3.7 V | 3.3 V nominal |
| Transmit current | 119 mA at 22 dBm | Higher than the 22 dBm part, burst rated | 119 mA at 22 dBm | About 120 mA at 20 dBm | About 100 mA at 20 dBm |
| Receive current | 6.8 mA | 6.8 mA | 6.8 mA | About 10 mA to 12 mA | About 10 mA to 12 mA |
| Host interface | SPI | SPI | UART with AT commands | SPI | SPI |
| Footprint | 14 x 20 mm SMD | 24 x 38.5 mm SMD | 16 x 26 mm SMD | 16 x 16 mm SMD | 17.3 x 16.8 mm SMD |
Included Models and Order Codes
The order codes below are the ones we quote most often. The suffix carries the band and the interface: 900 is the 868 and 915 MHz band, 400 is the 433 and 470 MHz band, M marks a bare SPI module and T marks a UART module with AT commands. Where a figure is not published for that exact code the cell is left empty rather than copied from a sister part.
| Part Number | Chipset | Band | Maximum output | Interface | Footprint |
|---|---|---|---|---|---|
| E22-900M22S | SX1262 | 850 to 930 MHz | 22 dBm | SPI | 14 x 20 mm SMD |
| E22-900M30S | SX1262 | 868 and 915 MHz | 30 dBm | SPI | 24 x 38.5 mm SMD |
| E22-400M22S | SX1268 | 433 and 470 MHz | 22 dBm | SPI | 14 x 20 mm SMD |
| E22-400M30S | SX1268 | 433 and 470 MHz | 30 dBm | SPI | 24 x 38.5 mm SMD |
| E22-400T22S | SX1268 | 430 and 470 MHz | 22 dBm | UART | 16 x 26 mm SMD |
| E32-868T20D | SX1276 | 868 MHz | 20 dBm | UART | 21 x 36 mm DIP |
| RFM95W-868S2 | SX1276 | 868 MHz | 20 dBm | SPI | 16 x 16 mm SMD |
| RFM95W-915S2 | SX1276 | 915 MHz | 20 dBm | SPI | 16 x 16 mm SMD |
| Ra-02 | SX1278 | 410 to 525 MHz | 20 dBm | SPI | 17.3 x 16.8 mm SMD |
| Ra-01 | SX1278 | 410 to 525 MHz | 20 dBm | SPI | 17.3 x 16.8 mm SMD |
Key Features
Sensitivity stated at a data rate – the -147 dBm figure belongs to 0.3 kbps, and a link budget quoted without the data rate is a different link entirely.
Second generation chipset cuts receive current – the SX1262 modules draw 6.8 mA in receive against 10 mA to 12 mA on the older SX1276 parts, which decides the life of a listening node.
Single cell supply on the SX126x parts – 1.8 V to 3.7 V means a lithium cell can feed the radio directly, without a boost converter and its quiescent current.
Both 22 dBm and 30 dBm in one footprint family – the E22 series keeps the pinout across power classes within a band, so a link that needs more margin can change part without a new board.
UART versions for products without a radio driver – the T codes take AT commands, which shortens the firmware work for a private point to point link.
Band split between 868 and 433 – the 900 codes cover 868 and 915 MHz and the 400 codes cover 433 and 470 MHz, and the band decides the duty cycle and the antenna length.
Sleep current in the microamp range – about 2 microamps in sleep lets a meter wake on a timer, transmit and return to sleep without a load switch.
Applications
These modules are quoted for products that need a link longer than Wi-Fi and cheaper than cellular, typically where:
Meter reading and utility networks – a water or electricity meter reports a few times a day, and a concentrator a few kilometres away collects a street at a time without a cellular subscription per meter.
Agriculture and environment monitoring – a soil or weather node runs from a solar cell, so the receive current and the sleep current decide whether it survives a cloudy week.
Industrial telemetry and remote control – a pump or a valve in a remote cabinet reports state over a private link, and the UART module keeps the controller firmware short.
The radio shares the board with the sensor front end and the antenna matching, so it is quoted with the SUPERB PCB and the SUPERB PCBA build for that board.
Sourcing and Cross-Reference
Selection starts with the link budget, not the output power. A 22 dBm module with a good antenna and a 6 dB margin beats a 30 dBm module with an antenna inside a metal cabinet, and the 22 dBm part is easier to power and easier to certify. The next figure is the data rate the application needs: a meter sending 50 bytes a few times a day can use the slowest spreading factor and take the full sensitivity, while a control loop needs a higher rate and gives up several dB.
The second check is the interface and the network. A private point to point link is fastest with a UART module and AT commands; a product that must join a LoRaWAN network needs an SPI part with a certified stack, or a module with the stack already inside. The third check is power: the SX126x parts run from 1.8 V to 3.7 V and draw 6.8 mA in receive, and the older SX127x parts want a clean 3.3 V rail and draw more, which changes the regulator and the cell.
Where a module is discontinued, the swap is checked on band, chipset, pinout, interface and certification together, because the same footprint with a different chipset needs a different driver. The route for obsolete and last time buy parts is on our source obsolete components page, and the band and pin comparison is on RF component sourcing. Related families are listed under frequency converters and sources and passive components.
For volume builds, SUPERB Assembly support covers the module footprint, the antenna matching network and the shielding over the radio section.
Q: Can you quote E22-900M22S and confirm whether the 30 dBm version keeps the same pinout and needs a different supply?
A: Yes. Send the band, the distance and the data rate, and the SUPERB Tech team will confirm the module, the sensitivity at that data rate and the supply current from the maker data sheet before quoting.
Why Buyers Source LoRa Modules Through SUPERB
- Link budget given with the data rate: sensitivity is quoted at the spreading factor the application will use, because the -147 dBm figure does not apply at every rate.
- Band and duty cycle stated together: 868 MHz and 433 MHz carry different duty cycle limits, and a 30 dBm part is not usable in every band at every rate.
- Receive and sleep current quoted: a listening node spends most of its life in receive, so the 6.8 mA figure on the SX1262 parts is part of the battery calculation.
- Interface matched to the firmware: SPI and UART versions are quoted with the driver work they imply, so a product without a radio driver is not sent a bare module.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: RF transceiver ICs for telemetry, SAW filters and duplexers, RF switches and PIN diode switches, LTE Cat 1 and Cat 4 modules.