VBP165R47S
Product Specifications
VBP165R47S
VBsemi — Discrete & Power Semiconductors
Product Overview
The VBP165R47S from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi specializes in discrete MOSFETs, power transistors, and protection devices at competitive cost for power supplies, motor control, and consumer electronics.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
VBP165R47S: 650 V and 47 A in a TO247 with 75 milliohm
The VBP165R47S is a single N channel MOSFET in a TO247 body, rated at 650 V drain to source, plus or minus 30 V on the gate, a 3.5 V threshold, 47 A of drain current and 75 milliohm at a 10 V gate. The vendor table lists a superjunction multiple epitaxy die. It shares its on resistance with the 36 A member of the family and carries a higher current label on the same die area class.
Two parts with the same 75 milliohm and different current labels are a normal pattern in a catalogue. The current label is set by the die area and the package thermal limit at a 25 C case, and the resistance is set by the same area. Where the labels differ and the resistance matches, the two are usually the same die binned at different test limits, and the higher label is the looser grade.
For a buyer the practical consequence is that the 47 A part and the 36 A part can be used interchangeably in most circuits, and the choice is price and availability. The higher label does not buy extra thermal capability, because the package and the heatsink set that.
Key data for the VBP165R47S
| Configuration | Single N channel |
| Package | TO247, through hole, tab on the drain |
| VDS | 650 V |
| VGS | Plus or minus 30 V |
| Vth | 3.5 V typical |
| ID | 47 A |
| RDS(on) at 10 V | 75 milliohm |
| Structure | Superjunction, multiple epitaxy |
| Loss at 12 A | 10.8 W |
| Loss at 24 A | 43.2 W |
| Loss at 35 A | 91.9 W |
| Loss at 47 A | 165.7 W |
Reading a catalogue label correctly
The current label on a TO247 part is the die current at a 25 C case with the junction at its maximum. It is a test condition, not a working target. At 47 A and 75 milliohm the die makes 166 W cold, and a TO247 junction to case resistance of 0.5 K per watt puts the junction 83 C above the case before the heatsink is even considered.
The working current comes from the thermal chain, not the label. A 1 K per watt heatsink at 40 C ambient and a 150 C junction allows 110 W total, and at 75 milliohm that is 38 A cold and 27 A hot. Add 2 W of switching loss and the hot figure falls to 26 A.
That calculation is why two parts with the same resistance behave the same whatever the label says. The label is a sorting result, and the number to quote on a purchase order is the resistance and the package, not the current.
Where the 47 A label comes from.
A larger die at the same resistance is not possible without a change of structure, so a higher current label at the same resistance means a different test limit or a different thermal path inside the package. Some makers rate at a 25 C case with an infinite heatsink, others at a 25 C ambient with a stated thermal resistance, and the resulting labels differ by 30 percent for the same die.
Across a family the label rises with the die area and the resistance falls, so the two move together. Where a label rises and the resistance stays, the difference is grading. Where the resistance falls and the label falls as well, the package has changed and the thermal path is worse.
This is the reason two suppliers can quote the same code with different current labels and both be correct. The number that travels between them is the on resistance at a stated gate voltage, and everything else is a local convention.
Loss and switching in a 1.5 kW stage
At 1.5 kW from a 400 V bus the input current is 3.75 A average and 10 A peak. At 75 milliohm the conduction loss at the peak is 7.5 W and the root mean square figure over the line cycle is 4.8 A giving 1.7 W. Switching at 400 V and 10 A with a 25 ns crossover is 5 W peak and 2.2 W averaged. Total 3.9 W, which a TO247 on a 1 K per watt heatsink holds at 70 C rise.
At 2.5 kW the peak is 16 A and the conduction loss is 19 W at the peak with 7.5 W root mean square. Switching adds 5 W and the total is 12 W, which is a fan cooled heatsink. That is where the 58 milliohm and 28 milliohm members of the family take over.
Where a board has to keep a single bill of materials across two power levels, this part is the compromise that runs both without a change of heatsink. The component lead time solutions page covers how one code is held across a range instead of splitting the volume.
Where this part fits
Power factor stages from 1 to 2.5 kW, LLC and forward converters at 400 V, electronic loads, and the primary of a welding inverter at 20 kHz. In a welding inverter the duty is low and the peak current is high, so the conduction loss at the peak is the number that sets the die temperature.
It also appears as a second source for the 36 A member, because the two are interchangeable in most circuits. A bill of materials that names both is easier to fill than one that names only the tighter grade.
In a bridge the body diode recovery has to be checked, and in a boost stage the boost diode recovery sets the turn on loss of this switch. The diode is the part that gets forgotten, and it is usually the reason a 650 V stage fails emissions.
The sourcing side of this part is covered on the safety stock planning. For a part that two power levels share, that page covers how much of each grade is held against the build plan.
Questions we get on this code
Is it the same die as the 36 A part? The resistance matches exactly and the voltage matches, so the two are likely the same die at different test limits. The vendor does not state it, so treat a swap as a thermal check rather than a guaranteed equivalence.
Which current should be used in a thermal calculation? The root mean square current at the working point, with the resistance taken hot. The printed 47 A is not usable in that calculation.
Does it need a gate resistor above 10 ohm? At 400 V and 10 A, 10 ohm gives a 300 ns transition, which is slow enough to keep the drain spike down. On a bridge at 100 kHz, 4.7 ohm is the usual starting point.
What is the tab capacitance to the heatsink? Not published. With a 0.3 mm insulating pad the coupling is in the 20 to 40 pF region, which matters for common mode emissions and is worth measuring on the first build.