LTM8033EY#PBF
Product Specifications
LTM8033EY#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM8033EY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM8033EY: the 3 A EMC module in the ball grid array, guaranteed from zero degrees
The LTM8033EY#PBF pairs the commercial temperature grade with the ball grid array body: 11.25 mm by 15 mm by 4.92 mm, SAC305 balls with the e1 finish, 2.2 g, and the same 36 V input, 3 A output converter inside. Output is 0.8 V to 24 V, switching is 200 kHz to 2.4 MHz, the reference is 790 mV and the ripple is 5 mV RMS. The guarantee runs from 0 to +125 degrees internal, with the range below freezing assured by characterisation, which fits a product that is built on a line with a wide process window and started in a building.
Published values
| Parameter | Value |
|---|---|
| Input range | 3.6 V to 36 V |
| Output range | 0.8 V to 24 V |
| Output current | 3 A at 24 V in; more with modules paralleled on the SHARE pin |
| Switching frequency | 200 kHz to 2.4 MHz |
| Reference | 790 mV at ADJ, 775 mV to 805 mV over the parts |
| Guaranteed range | 0 to +125 degrees internal |
| Output ripple | 5 mV RMS |
| Quiescent current | 30 microamps not switching |
| Emissions | radiated to EN55022 Class B; conducted with the standard filter |
| Thermal | 15.4 degrees per watt to ambient, 5.2 to the board |
| Package | 76 ball BGA, 11.25 mm by 15 mm by 4.92 mm, MSL 3, 2.2 g |
| Finish | SAC305 balls, e1, RoHS |
Why a BGA is the friendlier part on a high volume line
A ball grid array pulls itself into alignment during reflow, so a placement that is a little off still lands on its pads and the joint forms on surface tension. On a line running thousands of boards a month that tolerance converts directly into first pass yield, and it also widens the reflow window, which matters on a mixed board where the module is not the only large part.
The cost is height: 4.92 mm against 4.32 mm for the land grid array version. On a densely packed board that half millimetre can decide whether a connector, a shield or a lid fits above the module, so the choice between the packages is usually made by the mechanical drawing before anyone looks at the electrical table.
Zero degrees, on a product that is built indoors
The E grade is guaranteed over 0 to 125 degrees internal. Below zero the behaviour is characterised and correlated rather than guaranteed, so a product that is specified to start at minus 10 is asking for something the data sheet does not promise, while a product specified from 0 upward is fully covered. Storage is not affected: the part is rated to -55 in storage, so a cold warehouse does no harm.
Because the marking is the same across grades, the reel label is the only visible record. That is worth a line in the incoming inspection procedure for this family, particularly on a line that builds both an indoor and an outdoor variant of the same board.
Three amps, with a thermal number attached
The 15.4 degrees per watt path allows 2.6 W at an 85 degree ambient. Three amps at 5 V is 15 W out and needs 85 percent efficiency to stay inside, three amps at 3.3 V needs 79 percent and three amps at 12 V needs 93 percent. All three are inside what the converter does on a good board, and the 12 V point has the least margin.
Because the heat leaves through the pads, the copper under the module and the via array are part of the electrical bill. A four layer board with a continuous plane under the part meets the published number; a two layer board with a plane cut by traces does not, and the difference appears as a hot module rather than as a failed test.
Two pages worth reading before a purchase order goes out are OEM procurement and the power management cross reference; the first lists what else fits the socket, the second is the test sequence for a drop in, and vendor consolidation covers the case where the shortage is already on the line.
Two questions buyers ask about the BGA version
Does the BGA version need a different reflow profile? Yes, it needs a profile that lets the balls collapse, and the module is MSL 3 with 168 hours of floor life, so it needs baking after that. The land grid array version uses the paste volume and does not collapse.
Can this drive 6 A with a second module? Yes, with the SHARE pin and matched frequency resistors and feedback dividers. The two outputs are joined at the load, and the modules need a symmetric placement for the sharing to be even.