LTM8027EV#PBF
Product Specifications
LTM8027EV#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM8027EV#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM8027EV#PBF: BIAS1, the 4.5 V floor and what an always-on 48 V rail wastes
The LTM8027EV#PBF is the E grade of the 60 V, 4 A module in the 15 mm by 15 mm by 4.32 mm land grid array with Au pads and MSL 3. It runs from 4.5 V to 60 V in and delivers 2.5 V to 24 V at up to 4 A, with the output set by a resistor to ground on ADJ, which the module regulates to 1.23 V. Two pins decide most of the applications: BIAS1, which can take over the internal housekeeping supply, and SS, which sets the ramp.
Published values
| Parameter | Value |
|---|---|
| Input voltage | 4.5 V to 60 V, 7.5 V to start |
| Bias takeover | BIAS1 above 8.5 V shuts the internal linear regulator down |
| Low line operation | VIN down to 4.5 V while BIAS1 is above 6.5 V |
| Quiescent current | 39 mA typical into VIN, no load, 48 V in |
| Shutdown current | 9 uA |
| Output setting | RADJ = 613.77 / (VOUT - 1.23), in kohm |
| Soft start | capacitor on SS sets the ramp |
| Junction to ambient | 12.2 C/W |
| Package | 15 mm x 15 mm x 4.32 mm LGA, Au pads, MSL 3 |
| Temperature range | -40 C to 125 C, E grade |
Two bias pins and one wiring decision
The module generates its own housekeeping rail internally from VIN, with roughly 1 V of dropout, and that regulator can only source current. BIAS1 is where an external supply takes over: hold it above 8.5 V and the internal regulator shuts down, which removes its dissipation from the package and is the reason a 48 V to 12 V rail can reach the top of the efficiency curve. BIAS2 is the internal bias pin and follows BIAS1 in most arrangements, and the AUX pin is internally tied to VOUT so that a 12 V output can feed BIAS1 without a long trace back to the load.
The AUX pin is a convenience, not a load point: the data sheet says not to connect it to the load, because it is a sense tap inside the package and not a power output. Where the output is below 8.5 V, BIAS1 needs a source between 8.5 V and 15 V, and the usual answer on a 48 V board is a resistor and a zener or a small linear regulator from VIN, both of which have to be able to survive the same 60 V transients as the module.
What an always-on 48 V rail costs
Quiescent current into VIN is 39 mA typical at 48 V with no load, which is 1.87 W of standing loss. Over a year that is 16.4 kWh for a converter that is doing nothing, and it is the figure that decides whether a telecom board can leave the rail up in standby. The shutdown current is 9 uA, which at 48 V is 432 uW and 78.8 mAh over a year, so the RUN pin is worth using on any rail that is not needed continuously.
The 39 mA is a typical number at 48 V in and it rises with input voltage, so a 60 V bus is worse than the table suggests. On a board with three of these modules sitting idle in standby, the standing loss is 5.6 W inside three packages that have no airflow because nothing is running, which is exactly the condition where a thermal calculation is skipped and a hot spot appears.
Output setting arithmetic, and where the E96 values land
The ADJ pin is regulated to 1.23 V and the adjust resistor follows RADJ = 613.77 / (VOUT - 1.23) with the result in kohm. For 12 V that is 56.99 k, and the nearest E96 value of 56.2 k gives 12.15 V; for 5 V it is 162.8 k and 162 k gives 5.02 V; for 24 V it is 26.96 k and 26.7 k gives 24.22 V.
The error is small but it is systematic and it is in the same direction on every board built from the same bill of materials, so a 1 percent adjust resistor is the cheap way to keep a 12 V rail inside a 5 percent window that also has to cover the module's own reference tolerance. The 1.215 V to 1.245 V reference window over temperature is 2.5 percent on its own, which is most of a 5 percent budget before the resistor is considered.
Sourcing notes for this family: the power management cross reference holds the cross references, OEM procurement is the pre substitution check, and how to reduce component cost is what we use when the part on the drawing is not on the shelf.
Two questions buyers ask
Does BIAS1 have to be fed from the output? No. Anything between 8.5 V and 15 V works, and above 8.5 V the internal regulator shuts down. Feeding it from a 12 V output is the usual choice because the loss then comes from the output rather than from the 48 V input.
What happens below 7.5 V on the input? The module will not start. Once it is running and BIAS1 is held above 6.5 V, it keeps regulating down to 4.5 V on VIN, which is why a hold-up arrangement is a bias question before it is a capacitor question.