LTM4700EY#PBF
Product Specifications
LTM4700EY#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM4700EY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM4700EY#PBF: the E grade, the MSL 4 body and the 9.5 gram module on a reflow line
The LTM4700EY#PBF is the E grade of the dual 50 A or single 100 A digital module in the 15 mm by 22 mm by 7.87 mm ball grid array. The electrical headline is the same as the I grade: 4.5 V to 16 V in, 0.5 V to 1.8 V out, about 90 percent from 12 V to 1 V at 100 A, with PMBus telemetry and an EEPROM fault log. What separates the two order codes on the page is the guarantee, and what separates this part from a small module is the assembly and mechanical problem of a 9.5 g body with MSL 4 moisture sensitivity.
Published values
| Parameter | Value |
|---|---|
| Input voltage | 4.5 V to 16 V |
| Output voltage | 0.5 V to 1.8 V |
| Output current | dual 50 A or single 100 A |
| Efficiency | about 90 percent at 12 V to 1 V, 100 A |
| DC output error | plus or minus 0.5 percent over temperature |
| Current readback | plus or minus 3 percent, 25 degree C to 125 degree C |
| Digital interface | 400 kHz PMBus, 16-bit ADC |
| Thermal resistance | 8.5 degree C per W |
| Weight | 9.5 g |
| Moisture sensitivity | MSL 4 |
| E grade range | minus 40 degree C to 125 degree C |
| Package | BGA, 15 mm x 22 mm x 7.87 mm |
MSL 4 is a floor life of 72 hours, and a 9.5 g body holds heat
A moisture sensitivity level of 4 means the part has 72 hours of floor life at 30 degree C and 60 percent relative humidity after the bag is opened, and then it needs a bake before reflow. On a module that weighs 9.5 g the thermal mass is large enough that the reflow profile has to be measured on the part rather than taken from a small package: the balls under a body this size lag the thermocouple on the board edge, and a profile that looks right on a coupon can leave the corner balls below liquidus.
The practical consequence is that this part belongs on a line that controls floor life and has a bake capability, and a prototype built by hand needs a documented bake rather than an assumption that the bag was sealed. The same 9.5 g is why the part is usually placed on the first reflow side of a board and why the board has to be supported in the oven.
Where the 100 A output actually comes from
Two 50 A channels in parallel with current sharing give the 100 A figure, and the loss at that point is about 11 W from the 90 percent efficiency at 12 V to 1 V. That is 11 W through a ball array into the board, so the copper under the module is a thermal component and not just a connection. A board with 2 oz copper and a plane of vias under the module runs far cooler than one with 1 oz copper and a signal plane, and the difference can be tens of degrees at 100 A.
The single 100 A configuration and the dual 50 A configuration have the same loss at the same total current, so the choice between them is about how many rails the load needs and whether the phases can be interleaved. A single 100 A rail with the phases set 180 degrees apart has lower input ripple than two independent 50 A rails at arbitrary phase, which matters for the input capacitor bank.
The E grade in a system that has to prove its margins
Both E and I order codes are listed at minus 40 degree C to 125 degree C, and the difference is the guarantee rather than the window, so a build that needs a documented margin should take the readback accuracy and the dc error as they are printed and then add the measurement uncertainty of the PMBus path. Plus or minus 0.5 percent of 1 V is 5 mV, and plus or minus 3 percent of 50 A is 1.5 A, so a rail margined to plus or minus 5 percent from telemetry alone is operating inside the readback error of the instrument doing the margining.
The EEPROM fault log with ECC is the part of the module that survives the failure and makes the next build better. Faults, warnings and peak values are latched, so a rail that trips in the field leaves a record that can be read on the bench, and a fault that only appears at temperature is visible as a peak value rather than as a missing event.
When an order code in this family cannot be found, the power management cross reference lists what else does the same job, OEM procurement covers what to check before a part is dropped into an existing board, and component lead time solutions is the route we take on a live shortage.
Two questions buyers ask
Is the module a drop in for the I grade? Both order codes share the same body, the same ballout and the same electrical ratings, and the ordering table lists them separately with their own part markings. The substitution question is about the guarantee a build needs rather than about the footprint, and the answer for either has to include the MSL 4 floor life because that applies to both.
Can the output be margined without a bus master? The output voltage can be set at start-up by pin strapping, but margining at run time is a PMBus command and needs a bus master. A build without one gets a fixed rail set by the strap resistors with full telemetry available to whatever is connected, which is often a test fixture rather than the product.