Contact Us

LTM4650AIV#PBF

Brand: Analog Devices
Analog Devices LTM4650AIV#PBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTM4650AIV#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM4650AIV#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM4650AIV#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LTM4650AIV#PBF: The I Grade LGA for Rails That Have to Start Cold

The LTM4650AIV#PBF is the I grade, LGA version of the dual 25 A module: 4.5 V to 16 V in, 0.6 V to 5.5 V out, plus or minus 1 percent total DC error, 50 A with the channels tied, 16 mm by 16 mm by 4.41 mm, Au finish, 3.6 g, MSL 3. The difference from the E grade part next to it on the price list is the temperature guarantee: the I part is guaranteed over the full -40 C to 125 C internal range, where the E part is guaranteed from 0 C to 125 C and only assured over the wider range by characterisation.

Published values

ParameterValue
Input range4.5 V to 16 V
Output range0.6 V to 5.5 V per channel
Output current25 A per channel, 50 A single output
Total DC errorplus or minus 1 percent, 1.188 V to 1.212 V at 1.2 V
Reference0.600 V typical, 0.595 V to 0.605 V over temperature
Current limit30 A typical per channel
Bias current4.5 mA burst, 19 mA pulse skip, 115 mA continuous, 35 uA shutdown
Switching frequency500 kHz nominal, 250 kHz to 780 kHz programmable
Load step30 mV peak deviation, 20 us settle
Thermal7 C/W junction to ambient, 1.5 C/W junction to case bottom
Package16 mm x 16 mm x 4.41 mm LGA, Au finish e4, 3.6 g, MSL 3
TemperatureI grade guaranteed -40 C to 125 C internal
Absolute maximum18 V on VIN, 125 C junction, 245 C peak body

What the cold end of the range costs

A 1 percent window at 1.2 V is 24 mV, and the reference alone moves across 10 mV of that, 0.595 V to 0.605 V. The rest has to cover the internal feedback resistor tolerance and the amplifier offset. At -40 C the module is inside its guarantee, but the capacitors around it are not: a ceramic output bank that loses 60 percent of its capacitance at the cold end will let the load step deviation grow past the 30 mV published figure, which is measured at 25 C. Two thirds of cold start failures on a rail like this are the capacitor bank, not the module.

The 5 ms turn on time is set by 0.01 uF on TRACK/SS, and the ramp is monotonic because the tracking pin sets the reference slew rather than the error amplifier catching up. At -40 C the inrush into the output bank is the part that has to be checked: the published figure of 1 A is at 25 C with three 22 uF input capacitors and three 100 uF output capacitors.

Thermal budget in a sealed box

Two channels at 25 A and 1.2 V deliver 30 W. At 90 percent that is 3.33 W inside the module and a 23 C junction rise at 7 C/W. A sealed enclosure at 70 C internal air leaves 55 C of headroom to the 125 C limit, so a 23 C rise is comfortable, but the same enclosure with no airflow and a 50 A single output sees 6.67 W and a 47 C rise, which puts the junction at 117 C before any hot spot in the box is counted.

The bias current matters here more than it looks. 115 mA at 12 V is 1.38 W, and that figure is in the 3.33 W above. A rail that is enabled but not loaded still burns it, so a card that keeps its 1.2 V rail live while the load is in standby should be using burst mode, where the same bias is 4.5 mA and 54 mW. The 1.33 W difference is often larger than the load in standby.

Order code, grade and what to ask for on a quote

The code reads as follows: LTM4650A is the family, I is the grade, V is the LGA package with Au finish, and #PBF is the RoHS marking. Change the I to E and the part is cheaper with a 0 C guarantee, change the V to Y and it becomes the 5.01 mm BGA at 3.8 g. When a distributor quotes a lead time, the suffix is the thing to confirm in writing, because the same family ships in at least six order codes and the grade is not always obvious from the front of the part number.

The 4650A is pin compatible with the LTM4620A and the LTM4630A, so a 13 A or 18 A module can be fitted on the same footprint during a power budget review. That is a useful second source position: the same board can be built at three current levels while the power budget is being frozen, and the lower current parts are usually easier to find in stock when the higher one is on allocation.

Sourcing notes for this family: the obsolete part cross reference hub holds the cross references, component obsolescence management is the pre substitution check, and medical device components is what we use when the part on the drawing is not on the shelf.

Two questions buyers ask

Does the I grade need a different footprint from the E grade? No. Both are the same 16 mm by 16 mm LGA with the same 144 lands and the same Au finish, code e4. Only the guarantee changes, and the price. The same is true of the BGA pair: EY and IY share the 5.01 mm package and the SAC305 balls.

What is the difference between the 4650A and the 4650A-1? The -1 variants take the compensation network off the module and put it on the board, which is what a digital power system controller needs in order to trim the loop. The plain A part has the compensation inside and only the output set resistor outside, which is the simpler bill of materials for a fixed rail.