LTM2883IY-3S#PBF
Product Specifications
LTM2883IY-3S#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM2883IY-3S#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTM2883IY-3S#PBF: Six Isolated SPI Lines, Plus or Minus 12.5 V and 5 V, From One 3.3 V Rail
The LTM2883IY-3S#PBF is a complete galvanic isolator module for SPI or I2C. It carries six digital channels across a barrier rated 2500 V RMS for one minute under UL1577, with a maximum continuous working voltage of 560 V peak, and it generates isolated power on the far side: an adjustable plus or minus 12.5 V supply at up to 20 mA and a 5 V supply at up to 30 mA, both set by a single resistor. The -3 suffix is the 3.3 V primary supply version and the -S suffix is the SPI option, the logic supply pin accepts 1.62 V to 5.5 V independently of the main rail, and the module needs no external components. Digital isolation is rated at 10 MHz, SPI at 4 or 8 MHz, I2C at 400 kHz, common mode transient immunity is 30 kV per microsecond, and the body is a 15 mm by 11.25 mm by 3.42 mm BGA.
An isolated converter and an isolated data path in one package removes the usual failure mode of an optocoupler plus a separate isolated supply: two parts, two sets of creepage figures and two qualification reports. What it does not remove is the need to add up the isolated load before ordering.
The isolated side delivers 0.65 W and the primary side pays for it
Plus or minus 12.5 V at 20 mA is 0.25 W on each polarity, so 0.5 W in total, and 5 V at 30 mA is 0.15 W. The isolated load budget is therefore 0.65 W. At 70 percent conversion efficiency the primary draws 0.93 W, which from a 3.3 V rail is 282 mA, and that current is drawn continuously whether or not data is moving. A board that budgets the isolator as a logic part and forgets the 20 mA analogue rails will under-size the primary regulator by a wide margin.
Both isolated supplies are adjustable with one resistor each, so a system that needs plus or minus 15 V for a bipolar amplifier, or 5.5 V for a sensor, can move the set point rather than add a second converter. The adjustment range is limited by the transformer ratio, and the vendor specifies the nominal values at the stated currents, so a raised output is a lower current.
2500 V RMS for a minute is a test, 560 V peak is the working limit
The UL1577 rating of 2500 V RMS for one minute is a withstand test, and 2500 V RMS corresponds to 3536 V peak. The continuous working voltage is 560 V peak, which is 396 V RMS. The two figures differ by a factor of 6.3 on peak voltage, and they answer different questions: the first is what the barrier survives once, the second is what it holds every day for the life of the equipment. A board specification that quotes the UL number as an operating voltage is quoting a test result.
Common mode transient immunity of 30 kV per microsecond is the figure that decides whether communication survives a switching event on the far side. It is specified as the rate at which a transient can cross the barrier without corrupting data, and a motor drive or an inverter on the isolated side is exactly where that number is spent.
1.62 V to 5.5 V on the logic supply decouples the interface from the main rail
The logic supply pin is separate from the 3.3 V primary rail, so a 1.8 V FPGA on one side can talk to a 5 V device on the other without level shifters. The six channels cover the four SPI signals plus chip select and an interrupt, which is why the SPI option is a six channel part rather than a four channel one.
The shutdown mode draws under 10 uA. In a battery instrument that spends most of its life asleep, that is the mode the isolator lives in, and the isolated rails come back up with the module rather than through a separate enable.
| Function | Six channel digital isolator module with isolated DC power, SPI option |
| Isolation | 2500 V RMS for one minute per UL1577, 560 V peak working voltage |
| Isolated power | Plus or minus 12.5 V at 20 mA each, and 5 V at 30 mA, 0.65 W in total |
| Primary current | About 282 mA from 3.3 V at 70 percent conversion efficiency |
| Data rate | 10 MHz digital, 4 or 8 MHz SPI, 400 kHz I2C |
| Common mode | 30 kV per microsecond transient immunity |
| Logic supply | 1.62 V to 5.5 V, independent of the main supply |
| ESD | Plus or minus 10 kV HBM across the barrier |
| Shutdown | Under 10 uA |
| Package | 15 mm by 11.25 mm by 3.42 mm BGA |
Two questions buyers ask
Does the SPI option still pass I2C traffic?
No. The -S option is built for SPI timing and the -I option for I2C in master mode only. They are different order codes on the same body, and the difference is in the isolated channel behaviour rather than in the pin map, so a board that needs both protocols needs both order codes or a protocol decision made before the build.
Is 20 mA per polarity a hard limit?
It is the current at which the isolated supply is specified at its nominal voltage. Drawing more pulls the rail down and heats the module, and the 0.65 W total is what the primary side was sized for. An analogue front end that needs 30 mA on each polarity has to be split across two modules or fed from a separate isolated converter.
Ordering and supply
The IY suffix is the industrial BGA, the -3 is the 3.3 V primary supply and the -S is the SPI option. The same body is offered with a 5 V primary supply and with the I2C option, so the full order code has to be matched character by character: a -5 part on a 3.3 V rail will not start.
We carry this module for industrial and medical builds. The analog mixed signal ICs page lists what we hold, the medical device components page covers the isolation documentation that a medical build has to file, and where a board is being re-sourced, component lead time solutions describes how we handle a module that the vendor ships from allocation.
Request Quote — In Stock, 100% New & Original, Full Warranty