Contact Us

LTC6102IDD#TRPBF

Brand: Analog Devices
Analog Devices LTC6102IDD#TRPBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTC6102IDD#TRPBF — Analog & Mixed-Signal ICs | Superb Automation

LTC6102IDD#TRPBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTC6102IDD#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

LTC6102IDD#TRPBF: Ten Microvolts of Offset on a 60 V High Side Shunt

The LTC6102IDD#TRPBF is a high side current sense amplifier with a supply range of 4 V to 60 V, 70 V absolute maximum, an input offset of plus or minus 10 uV maximum, offset drift of plus or minus 50 nV per degree C maximum, an input bias current of 3 nA maximum, 130 dB minimum of power supply rejection, a 1 us step response, a maximum sense voltage of 2 V, and an output current capability up to 1 mA. Gain is set by two resistors, the part converts the sense voltage into an output current so a small differential signal on a large common mode becomes a ground referred voltage, and the package is an 8-lead MSOP or a 3 mm by 3 mm DFN. The high voltage version, the LTC6102HV, extends the supply to 100 V with 105 V absolute maximum.

The reason a 10 uV offset matters is the shunt. A 1 milliohm shunt at 10 A produces 10 mV, and an amplifier with 10 uV of offset is reading 0.1 percent on top of that. With a 100 uV offset the same measurement would carry 1 percent of error before the shunt tolerance, the gain resistors and the drift were counted.

50 nV per degree C over 165 degrees is 8.25 uV, still below the offset

Drift of 50 nV per degree C across the minus 40 to 125 C range is 8.25 uV, which is 0.82 times the 10 uV offset limit. That is the useful property of a zero drift amplifier: the drift term does not grow past the offset, so a system trimmed at 25 C stays trimmed over temperature. In a battery monitor that has to report current to 1 percent from a cold start to a hot enclosure, that is the difference between a calibration table and a single calibration point.

The 2 V maximum sense voltage is generous and it sets the shunt choice. At 2 V across a 1 milliohm shunt the current would be 2000 A, so the limit is never reached in practice; the real limit is the power dissipated in the shunt. A 0.1 milliohm shunt at 100 A dissipates 1 W and produces 10 mV, which is the same signal as the 1 milliohm example at 10 A with a hundred times less heat.

Output current, not output voltage, is the signal

The part converts the sense voltage into an output current, and a resistor from the output pin to ground turns that current back into a voltage. Gain is the ratio of two resistors, so a 1 kohm output resistor gives 1 V at the 1 mA output limit. Because the signal is a current, a long trace to the monitoring circuit does not drop voltage in the same way, and the gain can be changed by changing one resistor at the receiving end.

This order code is the plain LTC6102, so it has no disable mode. The -1 variant adds a shutdown that draws under 1 uA, which is the one to specify for a battery monitor that has to sleep. That difference is in the suffix and not in the family name.

FunctionHigh side current sense amplifier, current output
Supply4 V to 60 V, 70 V absolute, 100 V on the HV version
OffsetPlus or minus 10 uV maximum, 0.1 percent on a 10 mV sense
DriftPlus or minus 50 nV per degree C, 8.25 uV over 165 degrees
Sense range2 V maximum across the shunt
Supply rejection130 dB minimum, a ratio of 3.16 million
Response1 us step response
Bias current3 nA maximum
OutputCurrent output up to 1 mA, 1 V across 1 kohm
Package8-lead MSOP or 3 mm by 3 mm DFN

Two questions buyers ask

Can the sense resistor be made smaller to save power?
Yes, and that is what the low offset is for. A smaller shunt means a smaller signal and a larger gain, and the offset and the gain resistor tolerance become the error budget. At 10 uV of offset the practical floor is a sense of a few millivolts; below that the offset dominates and a chopper stabilised amplifier with an offset in the microvolt range is the next step.

Does the high voltage version change anything else?
It extends the supply and the common mode to 100 V with a 105 V absolute maximum, and the rest of the specification is the same. A 48 V telecom rail with transients is the case for the HV part, and a 12 V or 24 V system is served by the standard one.

Ordering and supply

The IDD suffix is the 3 mm by 3 mm DFN body on the industrial grade, and TRPBF is tape and reel, lead free. The -1 variant with the disable mode and the HV variant with the higher voltage are separate codes in a family of 36 part models, so the suffix is what identifies the function. The gain resistors are ordinary parts and their tolerance belongs in the same review as the shunt.

We supply this family for production and for repair. Start at the analog mixed signal ICs family page, compare a candidate against the amplifier cross reference, and where the measurement sits in a monitoring or medical product, the component list behind medical device components covers the shunt and the isolation that surrounds it.

Request Quote — In Stock, 100% New & Original, Full Warranty