Contact Us

LTC4367CDD#TRPBF

Brand: Analog Devices
Analog Devices LTC4367CDD#TRPBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTC4367CDD#TRPBF — Analog & Mixed-Signal ICs | Superb Automation

LTC4367CDD#TRPBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTC4367CDD#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

LTC4367CDD#TRPBF: The Same Protection Window, Raised to 100 V and 60 V of Operation

The LTC4367CDD#TRPBF is the 100 V member of the protection controller family. It operates from 2.5 V to 60 V, withstands 100 V at the input, protects against a reverse supply to minus 40 V, controls a pair of back-to-back N-channel MOSFETs, and consumes 70 uA in normal operation and 5 uA in shutdown. Overvoltage and undervoltage thresholds come from an external divider, a fault output reports the gate state, the turn-on delay is 32 ms, which debounces a live connection and blocks 50 Hz and 60 Hz AC, and the -1 variant recovers in 500 us instead. No input capacitor or transient suppressor is needed for most applications, the package is an 8-lead MSOP or a 3 mm by 3 mm DFN, and the part is AEC-Q100 qualified.

Sixty volts of operating range covers a 48 V rail with tolerance and a 36 V battery system with load dump, and the 100 V withstand covers the transient before the FET turns off. That is the difference from the 34 V part: the same function, one rail higher, for telecom, industrial and automotive 48 V systems.

Thirty-two milliseconds, and half a millisecond when the rail comes back

The 32 ms delay spans 3.2 half cycles at 50 Hz and 3.8 at 60 Hz, so an AC source cannot pass. The -1 variant's 500 us recovery is 64 times faster, which matters when the protection sits in front of a system that must restart quickly after a dip: 32 ms plus the processor's own boot is a visible interruption, while 500 us is not. The trade is that a short delay also lets a short disturbance through, so the choice is made by what the load can tolerate rather than by the controller.

Seventy microamps at 60 V is 4.2 mW, and 5 uA in shutdown is 43.8 mAh over a year. On a 48 V rail the divider that sets the thresholds is usually the larger standing current, so the controller's own consumption stops being the deciding term once the thresholds are tight. The 100 V withstand against a 48 V nominal rail leaves 52 V of headroom, which is enough for the inductive kick of a long cable without an external clamp.

Back-to-back FETs, and the gate drive that makes them work

The controller drives two N-channel devices in series with their sources joined, so the body diodes oppose each other and neither a reversed supply nor a negative transient can find a conducting path. Turning them on requires a gate voltage above the input, which the internal charge pump provides; the 60 V operating range means the pump has to hold that offset at the top of the range, and the external FETs have to be chosen so their threshold is well below it at the lowest input voltage.

The fault output is what makes the protection observable. A system that only sees its rail disappear cannot tell a reversed connector from a failed supply, and the difference matters in the field. With the fault line the controller reports that the gate is being held low because the input is outside the window, which turns a dead board into a diagnosable one.

Operating range2.5 V to 60 V, 100 V withstand
Reverse protectionMinus 40 V, back-to-back N-channel FETs
Turn-on delay32 ms, 3.2 half cycles at 50 Hz, 500 us on the -1 variant
Recovery speedThe -1 is 64 times faster than the plain part
Current70 uA operating, 4.2 mW at 60 V, 5 uA shutdown, 43.8 mAh over a year
Headroom52 V between a 48 V rail and the 100 V withstand
ThresholdsOvervoltage and undervoltage from an external divider
DriveCharge pump for high side N-channel FETs
QualificationAEC-Q100 for automotive use
Package8-lead MSOP and 3 mm by 3 mm DFN

Two questions buyers ask

Is this a drop-in for the 34 V part?
Functionally, with a different voltage window and a different pin body in some order codes. The 34 V part comes in a TSOT-23 as well, the 100 V part does not, so a board laid out for one is not automatically a board for the other. The threshold divider also has to be recalculated for the higher rail.

Does 100 V mean it survives a lightning surge?
No. It means the controller itself withstands 100 V, and the external FETs have to be rated for the same. A surge with significant energy needs a clamp in front of the pair, because the controller turning the FETs off does not absorb the energy, it only interrupts the path.

Ordering and supply

The CDD suffix is the 3 mm by 3 mm DFN on the commercial grade. The -1 variant with the 500 us recovery and the automotive-qualified suffix are separate order lines, and a part number that omits either will not deliver the behaviour the board was qualified against.

We source this family for production and for repair lots. Start at the analog mixed signal ICs family page, compare a candidate against the power management cross reference, and where a 48 V protection stage is being sourced, component lead time solutions sets out how an alternative is checked against the withstand, the delay and the charge pump rather than against the pin count.