LTC4121IUD#PBF
Product Specifications
LTC4121IUD#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTC4121IUD#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTC4121IUD#PBF: A 40 V Input, 400 mA Buck Charger With Input Voltage Regulation
The LTC4121IUD#PBF is a constant current, constant voltage synchronous step-down battery charger taking 4.4 V to 40 V at the input and delivering 50 mA to 400 mA into a battery, with an adjustable float voltage from 3.5 V to 18 V, plus or minus 1 percent feedback accuracy, plus or minus 5 percent charge current accuracy, efficiency up to 95 percent and a thermally enhanced 0.75 mm 16-lead 3 mm by 3 mm QFN package. In addition to the CC/CV loop it regulates its input voltage to a programmable fraction of the input open circuit voltage, which is the maximum power point technique for a high impedance source such as a solar panel.
The input voltage loop is the reason this part exists
A plain charger draws whatever current its output loop asks for, and a solar panel responds by collapsing its terminal voltage, which reduces the power it delivers. This part watches its own input voltage and reduces the charge current when that voltage falls to a programmed fraction of the panel's open circuit value, which keeps the panel at its maximum power point without a separate MPPT controller. The fraction is set by two resistors, and a panel with a 21 V open circuit voltage and a maximum power point at 17 V needs the divider set for 17 V rather than for 21 V.
At 400 mA into a 4.2 V battery the output is 1.68 W, and at 90 percent efficiency the input is 1.87 W, which is 77.8 mA from a 24 V source and 46.7 mA from a 40 V source. The part dissipates 0.19 W at 40 V in, so the 3 mm QFN is comfortable at the top of the input range and the input voltage rating is usable rather than nominal. A 40 V input with a 400 mA output is a 100:1 conversion ratio, and the part holds it at a switching frequency high enough to keep the inductor small.
| Input range | 4.4 V to 40 V |
| Charge current | 50 mA to 400 mA, programmable by one resistor, plus or minus 5 percent |
| Float voltage | 3.5 V to 18 V adjustable, fixed 4.2 V on the -4.2 code |
| Accuracy | Plus or minus 1 percent feedback, plus or minus 5 percent charge current |
| Efficiency | Up to 95 percent |
| Input regulation | Programmable fraction of the open circuit voltage, for maximum power point tracking |
| Termination | Timer, with auto-restart at a 2.2 percent drop, 92 mV on a 4.2 V cell |
| Protection | Bad battery detection, NTC qualified charging, fault pin |
| Package | 16-lead 3 mm by 3 mm QFN, 0.75 mm |
Termination, restart and the 2.2 percent window
Charging ends on a timer and the part signals end of charge, then drops into a low current sleep mode. It restarts when the cell falls 2.2 percent below the float voltage, which on a 4.2 V cell is 92 mV, so a product that sits on a charger holds its cell in a narrow band rather than cycling it between full and nearly full. That band is a compromise: a narrower one keeps the cell closer to full and costs more standby power, a wider one cycles the cell more and takes longer to recover. The 2.2 percent figure is fixed and the timer is set by an external capacitor.
The preconditioning and bad battery detection are what make the part usable with a cell that has been sitting discharged for months. A deeply discharged cell is charged at a low current until it reaches a threshold, and a cell that does not reach it within the timeout is flagged as bad rather than being charged at full current into a short. That protection is a fault pin and a register, and on a product with a sealed enclosure it is the difference between a reported fault and a returned unit.
The NTC input qualifies charging by temperature, which matters for a cell inside an enclosure that can be in the sun. Charging a Li-Ion cell below 0 C damages it, and charging it above 45 C shortens its life, so the thermistor and the divider that sets the window are part of the charging circuit rather than an accessory. A board that leaves the NTC pin fixed to a voltage disables a protection that the cell's data sheet assumes.
Solar, industrial and handheld applications
Solar powered devices are the first application, and the input regulation loop is what makes a small panel usable: a 1 W panel at 17 V delivers 59 mA, which is inside the 50 mA to 400 mA range and charges a small cell in a day. Industrial and military sensors are the second, where the 40 V input survives a 24 V backplane's transients and the wide float range covers several chemistries. Handheld instruments are the third, where a 400 mA charge rate from a 5 V adapter fills a small cell in a couple of hours.
The adjustable float voltage is what lets one part number serve several chemistries, from a 3.5 V lithium iron phosphate pack to an 18 V lead acid string, and the fixed 4.2 V member exists for the single cell Li-Ion case where a resistor divider is one more thing to get wrong. A board that uses the adjustable member has to set the divider from the data sheet's equation and check the plus or minus 1 percent accuracy against the chemistry's tolerance, because a 1 percent error on 4.2 V is 42 mV and some chemistries care about that.
Two questions buyers ask
Does it need an external MPPT controller for a solar panel?
No. The input voltage regulation loop is the maximum power point function, and it is set by a resistor divider to the panel's maximum power voltage rather than to its open circuit voltage. A separate controller would duplicate the function and add its own quiescent current to a solar product's standby budget.
Can it charge a battery from a 40 V rail continuously?
It can, at 400 mA and 0.19 W of dissipation, which the 3 mm QFN handles on a normal copper area. The input rating is a working range rather than a transient rating on this part, and the components around it, the inductor and the input capacitor, are what set the margin against a 40 V backplane's transients.
Ordering and supply
The LTC4121IUD#PBF is the adjustable float, 16-lead 3 mm by 3 mm QFN, lead free code. Cross references fail on the input voltage regulation and on the input range rather than on the charge current, because a 5 V charger with an MPPT pin is not the same part on a 24 V backplane. A replacement also has to keep the termination and restart behaviour if the product's runtime between charges depends on it.
We hold and source this family for production quantities and for repair lots. Start from the family page for analog mixed signal ICs, check a proposed alternative against the power management cross reference, and when a charger is short the supply route in component lead time solutions is where a graded alternative is arranged against the charging behaviour the product is specified on.
Request Quote — In Stock, 100% New & Original, Full Warranty