Contact Us

LT8613IUDE#PBF

Brand: Analog Devices
Analog Devices LT8613IUDE#PBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LT8613IUDE#PBF — Analog & Mixed-Signal ICs | Superb Automation

LT8613IUDE#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LT8613IUDE#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

LT8613IUDE#PBF: 42 V In, 6 A Out and 3 Microamps of Standby Current

The LT8613IUDE#PBF is a synchronous monolithic step-down regulator from Analog Devices in a 28-lead 3 mm by 6 mm QFN with an exposed pad. The input range is 3.4 V to 42 V, the output current is 6 A, both power switches are inside the package, and the quiescent current in burst mode is 3 microamps while regulating 12 V in to 3.3 V out with under 10 mV peak to peak of output ripple. Efficiency is 95 percent at 3 A and 5 V out from 12 V in and 94 percent at 3.3 V out, minimum switch on-time is 40 ns, dropout is 250 mV at 3 A, switching frequency is adjustable and synchronizable from 200 kHz to 2.2 MHz, and the enable pin has an accurate 1 V threshold. A rail to rail current sense amplifier with monitor and control pins allows input or output current regulation, and the power good flag reports the output window and fault conditions.

Forty nanoseconds of minimum on-time forbids a duty cycle

At 2.2 MHz the period is 454 ns, so 40 ns of minimum on-time is a floor of 8.8 percent duty. Converting 42 V to 3.3 V needs 7.86 percent, which is below the floor, so the regulator cannot hold 2.2 MHz at that ratio: it either folds the frequency back or skips pulses, and both change the ripple and the spectrum. Converting 42 V to 5 V needs 11.9 percent, which is inside the floor, and converting 12 V to 3.3 V needs 27.5 percent, which is comfortable. A 42 V input with a 3.3 V output therefore belongs at 1 MHz or below, and the smaller inductor that came with the 2.2 MHz plan cannot be kept.

Three microamps is 26 mAh over a year

Three microamps at 42 V is 126 microwatts, which over a year is 26 mAh of the source budget, and that is the figure that decides whether a module can be left connected to a battery in a parked vehicle. The trick is burst mode with a low ripple: holding the output ripple under 10 mV peak to peak while the part sleeps between bursts is what allows the supply to feed a microcontroller that wakes on a timer without an extra always-on regulator. In forced continuous mode the current rises to the switching losses and the 3 microamps no longer applies, so the mode is part of the specification, not a configuration detail.

The current sense amplifier is what the other 42 V parts do not have

Regulating current rather than voltage is what a battery charger, an LED string or a current limited supply needs, and it is normally done with an external amplifier and a shunt. Here a rail to rail sense amplifier with monitor and control pins is inside the package, so the same regulator can hold a current limit or a constant current output with a resistor and a reference. The output voltage range for current regulation is set by the load rather than by the divider, and the FB divider becomes the voltage limit that the loop falls back to when the load is disconnected.

ParameterPublished valueWhat it decides
Input3.4 V to 42 VCovers automotive load dump with margin
Output6 A, both switches internal1.58 W of loss at 30 W and 95 percent
Quiescent3 microamps in burst mode26 mAh over a year at 42 V
Burst rippleUnder 10 mV peak to peakAllows an always-on rail
Minimum on-time40 ns8.8 percent duty floor at 2.2 MHz
Dropout250 mV at 3 A83 milliohms, 3.05 V from a 3.3 V rail
Frequency200 kHz to 2.2 MHz, synchronizableTrade inductor size against duty floor
Power good9 percent window plus faults297 mV either side of 3.3 V

Can a 3.3 V output be held while the input falls to 3.3 V?

No, and the 250 mV of dropout at 3 A is the reason: the regulator needs about 3.55 V at the input to hold 3.3 V at 3 A, so a start-stop event that pulls the 12 V rail down through 3.5 V puts the output into dropout before the input reaches the output level. That is normal for a buck, and the usual answer is a boost or a buck-boost ahead of it, or a load that can run from 2.9 V during the event. The 3.4 V minimum input is the point below which the part is out of specification entirely, so the margin between 3.4 V and the actual sag is the question to answer.

Does the power good flag detect an overcurrent?

The flag reports when the output is outside 9 percent of the programmed value and also reports fault conditions, so an overload that pulls the rail down trips it, while a current limit that holds the voltage in regulation does not. The current limit itself comes from the sense amplifier and the resistor on its control pin, and the monitor pin gives the same signal as an analog voltage, so a controller can log how close the load runs to the limit rather than only learning that it was reached. The regulator range is on the power management cross reference, the long lead time alternatives for this package class are on the component lead time page, and the complete index is the analog and mixed-signal index.

Request Quote — In Stock, 100% New & Original, Full Warranty