LT6011CS8#TRPBF
Product Specifications
LT6011CS8#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT6011CS8#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LT6011CS8#TRPBF: 60 uV of Offset Against 3 mV of Bias Current Error
The LT6011 is a dual precision op amp with 60 uV maximum offset, 300 pA maximum input bias current, 135 uA of supply current per amplifier, 14 nV per root Hz voltage noise and a rail to rail output, specified from 2.7 V to plus and minus 18 V. The offset is the number in the title of every listing. The bias current is the number that decides what the offset is worth, because it turns the source resistance into an error the offset cannot describe.
Bias current against source impedance
300 pA into 1 Mohm is 0.3 mV, five times the 60 uV offset. Into 10 Mohm it is 3 mV, fifty times the offset. A stage fed from a high impedance sensor therefore has a bias current error that dominates everything the amplifier is praised for, and the 60 uV becomes irrelevant. Conversely, in a low impedance stage the bias current vanishes and the offset and its 0.8 uV per degree C drift are the whole error budget, which is why this part is chosen for thermocouple and photodiode work rather than for a bridge.
Noise, gain and power
14 nV per root Hz over a 10 kHz band is 1.4 uV RMS, so the offset is 43 times the noise in that band and trimming the offset actually buys accuracy. Open loop gain is 120 dB minimum at plus and minus 15 V, which is 1 ppm of gain error, and the output swings to within 40 mV of either rail, so a single 3.3 V supply gives a usable 3.2 V span. Supply current is 135 uA per amplifier, or 1.18 Ah over a year for a dual, which is a term to check in a battery instrument but not a limit in a mains powered one.
| Channels | dual (LT6011), quad member in the same family |
| Offset voltage | 60 uV maximum, 0.8 uV per degree C maximum drift |
| Input bias current | 300 pA maximum |
| Voltage noise | 14 nV per root Hz |
| Supply current | 135 uA per amplifier |
| Supply range | 2.7 V to plus and minus 18 V |
| Open loop gain | 120 dB minimum at plus and minus 15 V |
| Output | rail to rail, within 40 mV of either rail |
| Temperature and package | minus 40 to 85 C, 8 lead SO, 3 mm by 3 mm DFN |
Where it fits
Thermocouple amplifiers, precision photodiode stages, instrumentation front ends, battery powered precision systems and low voltage signal chains ahead of a 16 bit converter. The combination of 60 uV offset, 300 pA bias and 14 nV noise is unusual at 135 uA, which is why the part survives in boards that were laid out a decade ago.
Order code and availability
CS8 is the commercial grade in the 8 lead SO body, and the same silicon is offered in the industrial and DFN versions. The amplifier family is on the analogue and mixed signal line card.
Common questions
Is the commercial grade enough for an industrial product? It is specified from 0 to 70 C, so a product that must start at minus 20 C needs the industrial order code. The silicon is the same and the price difference is small compared with a field failure.
Does the 300 pA figure hold over temperature? It is a maximum at the specified temperature, and bias current roughly doubles every 10 C on a bipolar input. At 70 C the effective figure is several times the 25 C value, which is another reason the source impedance has to be part of the calculation.
Precision amplifier comparisons are on the amplifier cross reference page, and the medical instrumentation cases are on the medical device components page.
Request Quote — In Stock, 100% New & Original, Full Warranty