LT3094EMSE#TRPBF
Product Specifications
LT3094EMSE#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT3094EMSE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT3094EMSE#TRPBF: extended grade, 12-lead MSOP, same electrical table
The LT3094EMSE#TRPBF is the extended grade of the negative 500 mA regulator in the 12-lead MSOP, tape and reel. It is rated -40 C to 125 C at the junction, which is the same window as the I grade, and it shares the full table with the rest of the family: -1.8 V to -20 V input, 0 V to -19.5 V output, 235 mV dropout, 0.8 uV RMS noise, 74 dB rejection at 1 MHz, 100 uA SET pin at 1 percent and a 2.35 mA quiescent current that falls to 3 uA in shutdown.
Published values
| Parameter | Value |
|---|---|
| Input voltage | -1.8 V to -20 V |
| Output voltage | 0 V to -19.5 V |
| Output current | 500 mA |
| Dropout voltage | 235 mV typical |
| Output noise | 0.8 uV RMS, 10 Hz to 100 kHz |
| Supply rejection | 74 dB at 1 MHz |
| SET pin current | 100 uA, 1 percent initial accuracy |
| Quiescent current | 2.35 mA, 3 uA shutdown |
| Output capacitor | 10 uF ceramic minimum |
| Thermal resistance | 34 C/W junction to ambient, 5.5 C/W to case |
| Package and grade | 12-lead MSOP, -40 C to 125 C, tape and reel |
What E and I actually differ in
On this family the E and I grades share the same operating window and the same guaranteed limits over that window. The difference sits in the qualification and documentation package behind the part number, which is why a commercial build often lands on E and an industrial build often specifies I even though the bench data looks identical. For a buyer the practical point is that substitution between E and I is electrically transparent, while substitution between either of them and H or MP is not, because those grades extend to 150 C and carry different screening. When a line is short on one grade, moving between E and I is the safe move and moving down from H to E is only safe if the thermal calculation leaves real margin.
Negative rails in instrument and medical builds
The data sheet lists RF and precision supplies, very low noise instrumentation, high speed and high precision converters, medical diagnostics and imaging, and post regulation after a switching supply. In a medical instrument the negative rail usually feeds an op amp stage that sets the noise floor of the whole channel, so the 0.8 uV RMS figure is the specification the customer actually tests. In an imaging front end the same rail feeds a transducer driver that pulls current in bursts, and the load transient matters as much as the noise. Both cases want the SET pin capacitor in place and the output capacitor at 10 uF ceramic, and both benefit from the power good output, which reports that the rail is in regulation before a converter is allowed to start.
Sequencing and the enable pin
The enable pin on this part is bipolar and doubles as an undervoltage lockout input, so the rail can be held off until the upstream supply is valid, and the fast start-up feature brings the output up quickly once enabled. On a bipolar analog chain that matters: if the negative rail arrives after the positive one, the amplifier input sits outside its common mode range for a moment, and some converters latch into an odd state. The recommended order is positive rail first, then negative through the enable divider. The programmable power good output gives the controller a clean signal for that handshake instead of a fixed delay.
Buying the code
The E grade in MSOP is a mainstream stocked item, so the usual reason to look elsewhere is price pressure on a high volume build rather than availability. The two levers that change the price are the reel size and the grade, and neither changes the electrical table over the rated window. Buyers comparing this device against another negative regulator should hold the SET pin tolerance, the 10 uF minimum and the rejection at 1 MHz as the three numbers that decide whether the replacement is real. Our power management cross reference groups the negative rail codes, the second source notes for ADI parts set out the checks for a substitute, and the component cost page covers the volume levers.