ADPD188BI-ACEZR7
Product Specifications
ADPD188BI-ACEZR7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADPD188BI-ACEZR7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
ADPD188BI-ACEZR7: a smoke detection optical module with two wavelengths in a 3.8 mm by 5 mm package
The ADPD188BI-ACEZR7 is an Analog Devices integrated optical module for smoke detection that contains a photometric front end, a blue light emitting diode, an infrared light emitting diode and two photodiodes in a 3.8 mm by 5 mm by 0.9 mm package. The front end has a 14-bit converter with a 20-bit burst accumulator and three independently configurable LED drivers with synchronous detection. The package is built so that light cannot travel from an LED to a photodiode without passing through the smoke chamber. It supports UL-217 edition 8, UL-568 edition 7, EN-54, GB and ISO requirements, and the data output and configuration run over a 1.8 V I2C or SPI port. Dual wavelength detection with a higher signal to noise ratio is what the vendor offers as the way to reduce nuisance alarms. It is listed on the analog and mixed-signal IC line card.
Dual wavelength is the answer to the nuisance alarm problem
A single wavelength smoke detector cannot tell steam from smoke, because both scatter light. Two wavelengths see different ratios for large particles and small ones, so the ratio between the blue channel and the infrared channel carries information that a single channel does not. That is the entire argument for the module: a detector that can distinguish a shower from a fire does not get taken off a ceiling. The cost is two LEDs, two photodiodes and a calibration that has to hold over the life of the product, which is why the vendor offers loop calibration at final test and a reference chamber from a third party as a matched mechanical part.
| Parameter | Vendor figure | Derived figure |
|---|---|---|
| Package | 3.8 mm by 5 mm by 0.9 mm | 17.1 cubic millimetres for the whole optical system |
| Emitters | one blue and one infrared LED | two wavelengths, so a particle ratio is available |
| Detectors | two photodiodes | a reference channel as well as a signal channel |
| Converter | 14 bit with a 20-bit burst accumulator | 1,048,576 counts, 64 times the single shot depth |
| LED drivers | three, independently configurable | a spare driver for a third wavelength or a test LED |
| Discrete part count | 75 percent fewer components | the optical, analog and digital chain in one body |
| Power | 3 times lower dissipation than a discrete build | a smaller battery for the same life |
| Interface | 1.8 V I2C or SPI | connects to a 1.8 V microcontroller without a shifter |
| Standards | UL-217 ed. 8, UL-568 ed. 7, EN-54 | the certifications a smoke detector has to carry |
| Calibration | loop calibration at final test | the chamber is calibrated as an assembly, not as parts |
The 20-bit accumulator is what makes a low power optical measurement possible
An optical smoke detector works by measuring a very small scattered signal against a large ambient background, so the measurement is a difference between two large numbers. A 14-bit single shot gives 16,384 counts, and the scatter from a light smoke concentration may be a few tens of counts, which is inside the noise. Accumulating 1,048,576 counts before the comparison moves the resolution by 64 times without increasing the LED current, which is the same argument as averaging in software and is done here in hardware so the host can sleep. The synchronous detection rejects ambient light that is modulated at other frequencies, which is the difference between a detector that works under a fluorescent fitting and one that alarms every time the lights turn on.
Where the module stops and the chamber begins
The module contains the optics and the electronics and it deliberately does not contain the smoke chamber. The chamber geometry is what sets the optical path and therefore the sensitivity in obscuration per metre, so the same module in two chambers is two different detectors. The vendor supports a reference chamber from a third party, which is the practical route to a certification test without building a chamber from scratch. A product that builds its own chamber should expect to repeat the sensitivity characterisation, and that is a test campaign and not a datasheet calculation.
Selection notes
- The 0.9 mm height is the figure that allows a detector to be thin, and it is a mechanical constraint on the chamber as well as on the board.
- Three LED drivers mean the module can run blue and infrared alternately and still have a driver for a test emitter.
- The 1.8 V interface suits a modern low power microcontroller, and the module current is the dominant term in a battery detector.
- The standards list is the one to check against the target market before any other specification, because a module that does not support the local standard is not a candidate.
Questions buyers ask
Does the module include the smoke chamber? No. It includes the emitters, the detectors and the electronics; the chamber is a separate mechanical part that sets the optical sensitivity.
Why two wavelengths? The ratio between the blue and infrared channels separates large particles from small ones, which is how steam and cooking fumes are distinguished from smoke.
Sensor and optical parts for certified instruments are grouped in medical device components, and the supply question for a certified build is covered under component lead time solutions.
Request Quote — In Stock, 100% New & Original, Full Warranty