ADM3050EBRWZ-RL
Product Specifications
ADM3050EBRWZ-RL
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADM3050EBRWZ-RL from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
ADM3050EBRWZ-RL: Isolated CAN FD Transceiver at 5.7 kV
The ADM3050EBRWZ-RL is a signal isolated controller area network transceiver with a 5.7 kV rms isolation rating, rated for CAN FD at up to 12 Mbps. It puts the isolator and the transceiver in one SOIC body, so a node that has to be galvanically separated from the bus needs one part rather than two. Industrial drives, battery management systems and vehicle interface modules are where it turns up.
What the part is
A two channel isolator combined with a CAN physical layer transceiver, using the vendor's own transformerless isolation technology. The logic side runs from 1.7 V to 5.5 V and the bus side from 4.5 V to 5.5 V, so it interfaces to a 1.8 V processor without a level shifter. The device meets ISO 11898-2:2016 for CAN FD and supports data rates to 12 Mbps, with a maximum loop propagation delay of 150 ns. Common mode range is plus or minus 25 V, bus fault protection is plus or minus 40 V, common mode transient immunity exceeds 75 kV per microsecond, and a dominant timeout protects the bus from a stuck node. Current limiting and thermal shutdown cover output short circuits.
Key parameters
| Parameter | Value |
|---|---|
| Isolation rating | 5.7 kV rms for one minute, UL 1577 |
| Working voltage | 849 V peak |
| Data rate | up to 12 Mbps CAN FD |
| Standard | ISO 11898-2:2016 |
| Loop propagation delay | 150 ns maximum |
| Logic side supply | 1.7 V to 5.5 V |
| Bus side supply | 4.5 V to 5.5 V |
| Common mode range | plus or minus 25 V |
| Bus fault protection | plus or minus 40 V on both bus pins |
| Transient immunity | above 75 kV per microsecond |
| Emissions | passes EN 55022 class B by 6 dB |
| Temperature range | -40 C to +125 C |
What the numbers mean on a board
At 12 Mbps one bit is 83.3 ns and the 150 ns maximum loop delay is 1.8 bits, so the delay has to be inside the timing budget of the controller and not treated as a small correction. The 5.7 kV rms rating is 8060 V peak for a one minute test, while the continuous working voltage is 849 V peak, 9.5 times lower, so the headline figure is a withstand rating and the working voltage is what the insulation has to survive for years. A plus or minus 25 V common mode range and plus or minus 40 V fault protection mean the transceiver tolerates the wiring errors that happen on a 24 V industrial bus, and the dominant timeout is what stops one failed node from blocking every other node.
Where it is used
- Industrial automation and motor drives
- Battery management and energy storage systems
- Process control and building control networks
- Transport and infrastructure CAN nodes
Getting an isolated CAN node through certification
The isolation rating is quoted for a one minute withstand test while the continuous working voltage is 849 V peak, and the safety file has to name the part and the grade, so a substitution with a lower isolation version invalidates the certificate even though the pinout matches. The second item is the supply arrangement: the bus side needs 4.5 V to 5.5 V, which on a node without an isolated rail means either a small isolated converter or a bus powered arrangement, and the current that arrangement can deliver decides how many nodes the segment supports. The third is what surrounds the barrier. Creepage and clearance are properties of the board, not of the package, so the gap under and around the device has to be kept clear of copper, vias and solder mask openings. The fourth is the termination, which belongs at the ends of the bus and not at every node.
Sourcing notes and next step
The BRWZ code is the SOIC body with the 5.7 kV rating, and the same family includes lower isolation grades that are not interchangeable where a safety file names the part, so the code has to match the certificate. Transceiver selection for a bus that mixes classic CAN and CAN FD is covered on the CAN bus transceiver selection page, and where a released controller board is short of the part, matched sets are handled through BOM shortage recovery. The rest of the catalogue is on the analog and mixed signal family page. Send the order code, the isolation grade your file requires and the quantity, and we confirm stock and date code.
Request Quote — In Stock, 100% New & Original, Full Warranty