ADM2587EBRWZ-REEL7
Product Specifications
ADM2587EBRWZ-REEL7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADM2587EBRWZ-REEL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ADM2587EBRWZ-REEL7: isolated RS-485 transceiver with an integrated isolated supply
The ADM2587EBRWZ-REEL7 is a signal and power isolated RS-485 and RS-422 transceiver in the 20-lead wide body SOIC on tape and reel, configurable as half or full duplex. It carries 2.5 kV RMS of isolation, plus or minus 15 kV of ESD protection on the bus pins, and an isoPower DC to DC converter inside the same barrier, so a node needs one 5 V or 3.3 V supply on the logic side and nothing else. The E suffix code is the 500 kbps data rate version, against 16 Mbps for the ADM2582E on the same die family.
Published values
| Parameter | Value |
|---|---|
| Standard | ANSI/TIA/EIA-485-A-98 and ISO 8482:1987(E) |
| Data rate | 500 kbps on this code, 16 Mbps on the ADM2582E |
| Duplex | Half or full duplex, set by the pin connection |
| Isolation | 2500 V RMS for one minute, UL 1577 |
| Working voltage | 524 V peak per VDE 0884-17, approval pending at the datasheet revision |
| ESD on bus pins | Plus or minus 15 kV |
| Nodes per bus | Up to 256 |
| Receiver fail-safe | Open and short circuit inputs |
| Common mode transient immunity | Above 25 kV per microsecond |
| Supplies | 5 V or 3.3 V operation |
| Temperature range | Minus 40 C to plus 85 C |
| Package | 20-lead wide body SOIC |
500 kbps against 16 Mbps is a cable question
Both parts are in the same datasheet and share the same package and pinout, so the choice is made by the bus rather than by the board. RS-485 at 500 kbps reaches roughly 1200 metres on twisted pair, and at 16 Mbps the same cable is good for a few tens of metres. Choosing the fast part for a long field bus produces reflections and errors that no amount of termination fixes, because the limit is the cable rather than the driver. A file that buys the 16 Mbps code because it is the same price and then runs a 300 metre trunk is using the part outside its practical range, and the 500 kbps code is the correct order.
256 nodes and the fail-safe receiver
The 256 node count is one eighth unit load per receiver, which is four times the 32 node load of a classic 75176 style part. That matters in a large installation where every node counts, such as a building management network or a long conveyor with a drive at every station. The fail-safe receiver guarantees a defined output when the bus is open or shorted, or when no driver is active, which prevents a floating pair from producing random start bits that look like traffic. Both features are why this part appears on isolated field networks rather than on short in cabinet links.
The isolated supply and its emissions
The integrated DC to DC converter is a switching stage inside the isolation barrier, and the datasheet points at the vendor's application note on controlling radiated emissions with isoPower devices. That is not a formality: the converter switch node is the main emissions source in an isolated node, and the return path for its current is the isolated ground plane. A solid plane under the package, a small loop from the supply pins to the converter and a short connection to the bus connector are the difference between passing and failing a radiated emissions scan. On the positive side, the supply on the isolated side is already there, so the bus side needs no separate isolated brick.
Isolated field bus parts and their second source
A part that combines transceiver, isolation and supply is cheap to certify and hard to replace, so the second source question has to be answered before the build is frozen rather than during a shortage. The comparison criteria are on the CAN bus transceiver selection page, which covers the RS-485 family alongside the CAN parts, the schedule for the wide body SOIC is on the lead time page, and the second source position for isolated interface parts is described on ADI part second source.