Brand: Analog Devices
Analog Devices ADL5513ACPZ-R7 is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ADL5513ACPZ-R7 — Analog & Mixed-Signal ICs | Superb Automation

ADL5513ACPZ-R7

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The ADL5513ACPZ-R7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

ADL5513ACPZ-R7: 80 dB of detection range from 1 MHz to 4 GHz with a 20 ns response

The ADL5513ACPZ-R7 is an Analog Devices demodulating logarithmic amplifier that converts an RF input into a decibel scaled output, covering 1 MHz to 4 GHz with an 80 dB dynamic range at plus or minus 3 dB of log conformance and 74 dB at plus or minus 1 dB. Sensitivity is -70 dBm, the pulse response is 20 ns rise and 21 ns fall, the supply is 2.7 V to 5.5 V at 31 mA, and power-down drops the part to 1 mW at 5 V. Log conformance holds within plus or minus 0.5 dB over -40 C to +85 C, the operating range extends to +125 C, and the die is a silicon germanium process in a small LFCSP. The output can serve as a measurement or as a control voltage for a power amplifier loop. It is listed on the analog and mixed-signal IC line card.

Eighty decibels from -70 dBm reaches +10 dBm, and the useful window is narrower

The -70 dBm sensitivity plus 80 dB of range puts the top of the plus or minus 3 dB window at +10 dBm, which is 10 mW. The plus or minus 1 dB window of 74 dB is the one to use for a power control loop, and its top is +4 dBm. Between +4 dBm and +10 dBm the part still responds but the error grows to 3 dB, which in a control loop is 3 dB of setpoint error. That distinction decides the attenuator in front of the detector: a 20 dB coupler and a 10 dB pad put a 33 dBm transmitter at +3 dBm at the input, inside the tight window, while a direct connection would sit 6 dB above it and outside the guaranteed conformance.

ParameterVendor figureDerived figure
Frequency range1 MHz to 4 GHzthree and a half decades, one part
Dynamic range80 dB at plus or minus 3 dB-70 dBm to +10 dBm
Tight conformance74 dB at plus or minus 1 dB-70 dBm to +4 dBm
Response time20 ns rise, 21 ns fallburst detection beyond 50 MHz repetition
Temperature stabilityplus or minus 0.5 dB over -40 C to +85 C0.5 dB of the 74 dB window spent on temperature
Supply current31 mA at 5 V155 mW, more than many transmitters in standby
Power-down1 mW at 5 Va 155 to 1 ratio, 200 uA against 31 mA
Supply range2.7 V to 5.5 Vthe same detector on a 3.3 V and a 5 V board
Output usemeasurement or controllerthe same pin closes a power amplifier loop
Process and packagesilicon germanium, LFCSPthe speed comes from the process, not from the package

Twenty nanoseconds is what separates a detector from a power meter

A logarithmic detector that responds in 20 ns can follow the envelope of a burst, which means it can be used for pulse power measurement in a radar or a time division duplex radio, not just for a slow average. The other side of that speed is that the output carries the envelope, so a detector used as a power meter needs its output filtered and a detector used in a control loop needs the loop bandwidth set well below the envelope bandwidth of the signal. The 31 mA supply current is the price of the bandwidth: a slower detector with the same range would draw a fraction of that, and the choice is made by whether the system needs to see a pulse or an average.

Log conformance is not linearity in the usual sense

The output is a voltage proportional to the logarithm of the input power, and the error specification is the deviation from a straight line in decibels, not in volts. That is why the figures are quoted as plus or minus 1 dB and plus or minus 3 dB over a range rather than as a percentage. The slope is set by the internal gain stages and is not a printed number on the product page, so a system that needs an absolute power reading has to calibrate slope and intercept at at least one point, and two points are better. A system that only needs relative power, such as an automatic gain control loop, can use the part without any calibration at all, which is the usual case.

Selection notes

  • The 80 dB range is constant across the band, which is unusual and is what allows one detector to serve a multi-band radio.
  • Power-down at 200 uA makes the part usable in a duty cycled receiver, where the detector is only needed during a burst.
  • The output can drive a power amplifier control pin directly, so the loop can be closed without a second amplifier.
  • At 1 mW of power-down and 155 mW active, the duty cycle sets the average, and a 10 percent duty cycle brings the average to 15.5 mW.

Questions buyers ask

What is the highest input it can take accurately? +4 dBm for plus or minus 1 dB and +10 dBm for plus or minus 3 dB. Above that the part still responds but the reading is not a power measurement.

Can it measure a pulsed signal? Yes. The 20 ns response follows an envelope, so a burst longer than a few tens of nanoseconds is resolved; a shorter burst is integrated by the detector and reads low.

Detector and amplifier alternatives are compared in amplifier cross reference, and lead time for a qualified RF build is covered under component lead time solutions.