ADG5462FBCPZ-RL7
Product Specifications
ADG5462FBCPZ-RL7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADG5462FBCPZ-RL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
ADG5462FBCPZ-RL7: a channel protector with a trip point you set
The ADG5462FBCPZ-RL7 contains four overvoltage protected channels in series with the signal path, on 10 ohm typical on resistance with 0.5 ohm of flatness, in a 4 mm by 4 mm LFCSP. The channel blocks faults up to plus or minus 55 V with the supplies present and with them absent, detects an overvoltage on the source pin, and raises an interrupt flag. Unlike a fixed threshold protector, the trip level is set by a secondary supply that the user provides. Dual supply operation covers plus or minus 5 V to plus or minus 22 V and single supply covers 8 V to 44 V, and the part is fully specified at plus or minus 15 V, plus or minus 20 V, 12 V and 36 V. It is listed in the analog and mixed-signal IC line card with the rest of the switch and protection range.
What 10 ohm costs, and what it buys
Ten ohm in series with a signal is a small error at high impedance and a real one at low impedance. The table below turns the on resistance into the numbers a signal chain actually sees:
| Load or signal | Voltage drop at 10 ohm | Error |
|---|---|---|
| 1 mA signal current | 10 mV | 10 mV of offset in the path |
| 10 mA signal current | 100 mV | 100 mV, usually outside a 3.3 V input range |
| 1 kohm load | 1 percent gain error | |
| 10 kohm load | 0.1 percent gain error | |
| 0.5 ohm flatness into 10 kohm | 0.005 percent of nonlinearity | |
| 55 V fault across the off channel | none, the channel is off | 5.5 A would flow if it conducted |
The last row is the point of the part. A 55 V fault presented to a 10 ohm path would be 5.5 A if the channel stayed on, which no 4 mm package can carry. The protector turns the channel off, so the fault sits across an open switch rather than across the load, and the interrupt flag reports it instead of the load being damaged.
The secondary supply is the trip point
The overvoltage level is not a fixed number in this part. It is set by the secondary supply, which has a 4.5 V minimum in single-supply operation. That means the board has to provide a rail that represents the highest legal signal, and the protector compares the source pin against it. Two consequences follow: a board that omits the secondary supply has no user-defined level at all, and a board that derives the secondary supply from the same rail it is protecting loses the reference when that rail collapses.
The 4 kV human body model rating is a handling figure. In a system the relevant number is the plus or minus 55 V the channel blocks, which is well above the 24 V and 48 V industrial buses the part is normally used on.
Selection notes
- Four channels in one body means four signal lines share one fault flag. If the host has to know which line faulted, the flag has to be paired with a scan of the four source pins.
- Power-off protection is separate from powered protection and both are specified to plus or minus 55 V, which is what allows the protector to sit in front of a card that can be unplugged while the field wiring stays live.
- Latch-up immunity is stated unconditionally, so the part does not need the supply sequencing that a conventional CMOS switch needs to avoid a latch on a fault.
- On-resistance flatness of 0.5 ohm is what keeps the distortion low for a signal that swings over the full range; the absolute 10 ohm only scales the signal.
Questions buyers ask
How is the trip level set? By the secondary supply the board provides, with a 4.5 V minimum in single-supply operation. The level is a board decision, not a part number decision, which is why the same order code covers different fault thresholds.
What is the difference from the ADG5413F? The ADG5413F is a quad single-pole single-throw switch with two normally open and two normally closed channels and a fixed internal threshold. This part is a channel protector with a user-defined threshold and a fault flag, so the choice is between switching convenience and a settable trip point.
What should a quote request include? The order code, the supplies, the signal range, the fault voltage the field wiring can present, and the load impedance behind the protector. Send the BOM line to the drop-in verification desk when it replaces an existing protector, and to the medical and instrumentation range when the application is a patient-connected input that has to survive a defibrillation event.
Request Quote — In Stock, 100% New & Original, Full Warranty