ADA2200ARUZ
Product Specifications
ADA2200ARUZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADA2200ARUZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
ADA2200ARUZ: Synchronous Demodulation With No Converter Behind It
The ADA2200ARUZ is a synchronous demodulator with a configurable analogue filter. It takes a modulated signal, multiplies it against a reference clock and filters the result in the analogue domain, so a small signal buried in noise can be recovered before any converter sees it. Boards that use it are usually measuring an impedance, a capacitance or a photodiode current where the wanted information sits inside a narrow band and the interfering signals do not.
What the part is
A sampled analogue signal path with a demodulator and a low pass filter whose corner tracks the input clock, so the measurement bandwidth moves when the clock moves without rewriting coefficients. Signal input bandwidth reaches 30 kHz, and the part accepts single ended or differential inputs and drives single ended or differential outputs that can go straight into a converter. Phase detection sensitivity is 9.3 millidegrees rms. Configuration is through a 3-wire or 4-wire serial port, or by booting from an I2C EEPROM when the host has no spare pins. Supply current is 395 uA at a 500 kHz clock on a 2.7 V to 3.6 V rail.
Key parameters
| Parameter | Value |
|---|---|
| Function | synchronous demodulator with configurable analogue filter |
| Input bandwidth | to 30 kHz |
| Filter corner | tracks the input clock frequency |
| Phase detection sensitivity | 9.3 millidegrees rms |
| Inputs and outputs | single ended or differential, rail to rail output |
| Supply current | 395 uA at a 500 kHz clock |
| Supply range | 2.7 V to 3.6 V |
| Interface | 3-wire or 4-wire serial, or I2C EEPROM boot |
| Temperature range | -40 C to +85 C |
| Package | 16-lead TSSOP |
What the numbers mean on a board
395 uA at 3 V is 1.19 mW, which is low enough to leave the part powered between measurements instead of cycling it and waiting for settling. 9.3 millidegrees rms is 1.62e-4 radians, so the phase error of the demodulator is far below the phase error of the sensor and the reference path in almost every application. Because the filter corner follows the clock, a 500 kHz clock against a 30 kHz signal is a ratio of 16.7, and a change of clock frequency moves the measurement bandwidth with it. That is convenient, but it also means the transfer function cannot be copied from one clock setting to another, and a fixed frequency substitute never reproduces the same response.
Where it is used
- Capacitive and resistive touch and proximity sensing
- Photodiode and optical absorbance measurement
- Impedance and conductivity probes in process instruments
- Industrial sensors that need narrow band extraction
Getting a clean demodulated output
The output of a sampled demodulator carries images at multiples of the clock, so the filter after it has to remove those images rather than the signal band. A single pole that is set to the demodulator bandwidth will leave clock energy in the measurement. The second point is the reference path: the phase accuracy of the result depends on the clock that drives the part, so a jittery clock turns directly into phase noise in the measurement. The third is settling. Because the filter corner follows the clock, changing the clock to change the bandwidth also restarts the settling time, and a reading taken too early belongs to the previous setting.
Sourcing notes and next step
The sampled analogue output carries clock images, so the converter behind it needs an antialiasing filter that matches the clock rather than the signal band, and that is the most common question we get on this part. Amplifier choices around the demodulator are collected on the amplifier cross reference page, and instrument grade options including medical front ends sit on the medical device components page. The full catalogue is on the analog and mixed signal family page. Send the order code, quantity and target date and we confirm stock and date code.
Request Quote — In Stock, 100% New & Original, Full Warranty