AD9847AKSTZ
Product Specifications
AD9847AKSTZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD9847AKSTZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
AD9847AKSTZ: 10 Bit 40 MSPS CCD Front End for Camera Lines
The AD9847AKSTZ is the 40 MSPS member of a family of charge coupled device signal processors, with a 10 bit converter, correlated double sampling, two gain stages and a timing driver in a 48-lead LQFP. It is used in camera and imaging products where the pixel rate is higher than the 30 MSPS devices in the same family can handle. The vendor marks it not recommended for new builds, so this page mostly serves existing production.
What the part is
An analogue front end with black level clamping, correlated double sampling, a pixel gain amplifier from -2 dB to +10 dB and a 10 bit variable gain amplifier from 2 dB to 36 dB, feeding a 10 bit converter at 40 MHz. The precision timing core resolves 500 ps at 40 MSPS, and the horizontal and reset gate drivers run from 5 V on chip, so the sensor clocks are generated beside the analogue chain. Programming is through a 3-wire serial interface, and the specified operating range is -20 C to +85 C, which is narrower than the industrial parts around it.
Key parameters
| Parameter | Value |
|---|---|
| Resolution | 10 bit |
| Pixel rate | 40 MHz |
| Correlated double sampler | integrated |
| Pixel gain amplifier | -2 dB to +10 dB |
| Variable gain amplifier | 2 dB to 36 dB, 10 bit |
| Black level clamp | variable level control |
| Timing resolution | 500 ps at 40 MSPS |
| Gate drivers | 5 V horizontal and reset gate outputs on chip |
| Interface | 3-wire serial |
| Temperature range | -20 C to +85 C |
| Package | 48-lead LQFP |
What the numbers mean on a board
At 40 MSPS there are 25 ns per pixel and the 500 ps timing step is 2 percent of that, which gives finer placement of the sample point than the 30 MSPS member of the family at 1 ns. Ten bits against twelve is the real difference: the same analogue chain with one quarter of the code count, so the gain stages have to be set to fill the converter rather than leaving headroom. The minus 20 C lower limit rules the part out of equipment that has to start in an unheated outdoor cabinet, and that single number is often the reason a board moves to the 12 bit member instead.
Where it is used
- Digital still cameras and camera modules
- Industrial inspection and machine vision heads
- Document scanners and imaging peripherals
- Legacy imaging platforms in continuing production
What changes when a 12 bit camera becomes 10 bit
The analogue chain is the same shape, so the difference is code count and headroom. With four times fewer codes, the gain has to be set so the brightest part of the scene reaches the top of the range without clipping, and the black clamp has to be set so the darkest part still sits above zero. Any margin that was carried for a 12 bit converter is now a visible loss of contrast. The second change is the timing. A 500 ps step at 40 MSPS is finer than the 1 ns step of the 30 MSPS part, so a timing table copied between the two does not land on the same sample point. The third is temperature: the minus 20 C lower limit is a real restriction on outdoor equipment, and a cabinet that starts cold will show a timing shift before it warms up.
Sourcing notes and next step
The difference between this part and its 12 bit sibling is one order code apart, and a camera line that substitutes one for the other changes its effective resolution, so the code has to be matched exactly on a repeat order. Continuing supply routes for parts the vendor no longer recommends are described on the obsolete part cross reference hub, and imaging front ends for instrument products sit on the medical device components page. The full catalogue is on the analog and mixed signal family page. Send the annual quantity and the date codes you can accept, and we confirm what stock exists.
Request Quote — In Stock, 100% New & Original, Full Warranty