AD8607ARMZ
Product Specifications
AD8607ARMZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD8607ARMZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AD8607ARMZ: dual micropower amplifier with 50 microvolts offset in MSOP-8
The AD8607ARMZ is the two channel member of the AD8603/AD8607/AD8609 family in an 8-lead MSOP: a 50 uV maximum offset, a 1 pA maximum bias current, 25 nV/root Hz of noise and 40 uA of supply current per amplifier from a 1.8 V rail. It is the low power end of the precision range, and the numbers it gives up are bandwidth and slew rate rather than accuracy.
Published values
| Parameter | Value |
|---|---|
| Offset voltage | 12 uV typical, 50 uV maximum |
| Offset voltage drift | 1 uV/C typical, 4.5 uV/C maximum |
| Input bias current | 0.2 pA typical, 1 pA maximum |
| Input voltage range | 0.3 V beyond both rails |
| Supply current, both channels | 80 uA typical, 100 uA maximum |
| Gain bandwidth | 400 kHz at 5 V, 385 kHz at 1.8 V |
| Slew rate | 0.1 V/us |
| Voltage noise density | 25 nV/root Hz at 1 kHz |
| Settling to 0.1% | 23 us on a 2 V step at unity gain |
| CMRR and PSRR | 80 dB minimum, 98 to 100 dB typical |
| Thermal resistance, MSOP-8 | 142 C/W junction to ambient |
| Supply range | 1.8 V to 5 V single supply |
The same accuracy as a 25 microvolt class part for a fortieth of the current
Measured on offset, drift and bias current, this amplifier sits in the same class as a 10 MHz low noise part: 50 uV against 65 uV, 4.5 uV/C against 4.5 uV/C, 1 pA against 1 pA. What it does not have is speed. At 0.1 V/us a 2 V step takes 20 us and the published settling is 23 us, so the usable signal bandwidth is around 4 kHz in a gain of 10 and 400 kHz at unity gain with a small signal. A circuit that needs the accuracy and not the speed saves 2 mA by choosing this part.
Noise against source impedance, not in isolation
Twenty-five nanovolts per root hertz looks high next to an 8 nV part, and it only matters if the source impedance is low. At 1 kOhm the resistor adds 4 nV and the total is 25.3 nV. At 100 kOhm the resistor adds 40 nV and the total is 47 nV, so the amplifier contributes a third of the noise power and the difference between a 25 nV and an 8 nV part is small. This is the calculation that decides between the two families for a bridge or a photodiode.
Two channels in a 3 mm body
The MSOP package is 3 mm by 3 mm with a 0.65 mm pitch, and at 142 C/W it runs cool: 100 uA at 5 V is half a milliwatt. In a battery instrument the two channels can therefore sit next to the sensor without a thermal gradient of their own, which matters when the sensor is a thermocouple and the cold junction is the board itself.
Where the part belongs
Portable gas and electrochemical sensors, thermopile and thermocouple channels, single cell medical monitors, and any two channel DC front end that has to run from 1.8 V. Above 10 kHz of signal, or where the channel has to be scanned quickly, the 10 MHz family is the correct answer and the current budget has to make room for it.
For a board that has to keep running while a reel runs out, medical device components is where the family alternatives sit, the amplifier cross reference is the check list before a substitute goes in, and how to verify a drop in replacement is how a gap is covered without a new line item.
Two questions buyers ask
Can the AD8607ARMZ be used at 1.8 V with a 1.8 V sensor output? Yes. The input range extends 0.3 V beyond both rails, so a sensor that sits at the positive rail can still be measured, and the offset specification does not degrade at 1.8 V.
What is the settling time for a full scale step? About 23 us to 0.1 percent on a 2 V step, which is set by the 0.1 V/us slew rate rather than by the loop.