AD8496ARMZ-R7
Product Specifications
AD8496ARMZ-R7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD8496ARMZ-R7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
AD8496ARMZ-R7: J-Type Thermocouple Amplifier With Cold Junction Compensation on Chip
The AD8496ARMZ-R7 is the 8-lead MSOP body of the AD8496, a thermocouple amplifier precalibrated for J-type (iron constantan) couples, with cold junction compensation on the die, in production. It delivers 5 mV per degree C directly from the couple, runs from a supply between 3 V and 36 V, draws 180 uA unloaded, and can source or sink more than 5 mA at its output, which is enough to drive a setpoint comparator or a relay driver. The J-type calibration is what separates this order code from the AD8495 and AD8497 in the same family, which are trimmed for K-type couples. Thermocouple front ends and their alternatives are compared from the amplifier cross reference page.
What the numbers actually mean
Five millivolts per degree C over the J-type range of 25 to 100 degrees C is 375 mV of output swing, which sits comfortably on a single 5 V rail. On a 3 V supply the same output covers the same span and is a large fraction of the rail, so the reference pin is what sets where that span sits. The 180 uA of supply current is 0.9 mW at 5 V, low enough that self heating in the MSOP body is not a measurement error, which is the reason the figure is quoted unloaded.
| Parameter | Figure | What it decides in a build |
|---|---|---|
| Couple type | J type, precalibrated | No software linearisation table for the J curve |
| Output | 5 mV per degree C | 375 mV across 25 to 100 degrees C |
| Cold junction | Compensation on the die | Removes the ice point reference from the board |
| Supply | 3 V to 36 V, 180 uA | 0.9 mW at 5 V, so self heating stays out of the measurement |
| Output drive | More than plus or minus 5 mA | Drives a comparator or a small load without a buffer |
| Protection | Overvoltage to supply plus or minus 25 V, 4 kV ESD | Survives a thermocouple lead that touches a heater supply |
| Package | 8-lead MSOP | Fits at the connector, which is where the cold junction is |
Where it can surprise a build
Cold junction compensation works only if the part is at the same temperature as the cold junction. That means the package has to be isothermal with the terminal block, and a part mounted 20 mm away on a board with a warm regulator is compensating for its own temperature rather than the connector's. This is a mechanical requirement disguised as an electrical one, and it is the most common reason a thermocouple channel reads a few degrees off.
The output is 5 mV per degree C with a reference pin that offsets the zero. On a single supply, the reference pin has to be raised so that the range does not clip at the low end, and the noise on that reference appears directly in the measurement at the same scale. A reference with 1 mV of noise is 0.2 degrees C of noise.
Break detection exists, and it depends on the input bias current flowing through the couple. A thermocouple that is welded to a grounded sheath has a different return path, so the detection behaves differently, and a system that relies on it for safety has to test the detector with the actual probe wiring.
Applications and how it fits a temperature loop
J-type thermocouple measurement, setpoint controllers, standalone Celsius thermometers, universal cold junction compensation, white goods such as ovens and cook tops, exhaust gas temperature sensing and catalytic converter temperature sensing. The J-type range and the low supply current make it a natural fit for appliances and for automotive exhaust sensing, where the environment is hot and the electronics have to be simple. Where a board has to be re-sourced, BOM shortage recovery covers the checks that separate a J-type calibrated part from a K-type one with the same pinout.
The other thermocouple members and the wider signal chain are on the analog and mixed-signal IC page.
Questions buyers ask about this order code
Can this part be used with a K-type couple? Not without a software correction and a different cold junction slope, because the calibration is trimmed to the J curve. The K-type members of the family are separate order codes, and mixing them is a silent error of several degrees.
Does it need a negative supply? No. It runs from a single 3 V rail and measures below 0 degrees C by offsetting the reference pin, which is the reason that pin exists.
Is the 5 mV per degree C output linear over the whole J range? It is precalibrated across the range the part is specified for, and the couple's own curve is not perfectly linear, so the residual is the couple's non linearity rather than the amplifier's. Above the specified range the error grows and the data sheet table is the reference.
Request Quote — In Stock, 100% New & Original, Full Warranty