AD8421BRMZ-R7
Product Specifications
AD8421BRMZ-R7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD8421BRMZ-R7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
AD8421BRMZ-R7: 3.2 nV of Input Noise and 500 pA of Bias Current From 2.3 mA
The AD8421BRMZ-R7 is a low power instrumentation amplifier from Analog Devices in an 8-lead MSOP. Maximum input voltage noise is 3.2 nV per root hertz at 1 kHz and current noise is 200 fA per root hertz, supply current is 2.3 mA maximum, and bandwidth is 10 MHz at a gain of 1 and 2 MHz at a gain of 100. Settling to 0.001 percent is 0.6 microseconds at a gain of 10 and 0.8 microseconds at a gain of 100, slew rate is 35 V per microsecond, and common mode rejection is 80 dB to 20 kHz at a gain of 1. The B grade carries 94 dB minimum common mode rejection at a gain of 1, 0.2 microvolts per degree C maximum offset drift and 1 ppm per degree C maximum gain drift. Input bias current is 500 pA maximum, the inputs survive 40 V from the opposite supply, the supply is plus or minus 2.5 V to plus or minus 18 V or 5 V to 36 V single ended, and gain is set by one resistor from 1 to 10,000.
The noise figure only means something over a band
A spectral density turns into a voltage once a bandwidth is chosen. Over 1 kHz the 3.2 nV per root hertz is 0.10 microvolts RMS, over 10 kHz it is 0.32 microvolts, over 100 kHz it is 1.01 microvolts and over 1 MHz it is 3.2 microvolts. At a gain of 100 the amplifier bandwidth falls to 2 MHz, which gives 4.5 microvolts of input referred noise, and the source resistance adds its own thermal noise on top. This is why a 24-bit converter behind this part does not deliver 24 bits: the amplifier alone puts more noise into a 10 kHz band than the converter's own 0.30 microvolt floor at 20 samples per second. The honest comparison is always noise against bandwidth against the sensor's own output, never a density figure on its own.
0.6 microseconds to 0.001 percent is a 3 MHz pole, not a 10 MHz one
Settling to 0.001 percent needs about 11.5 time constants, so 0.6 microseconds is a 52 ns time constant, which is a single pole near 3 MHz. The 10 MHz bandwidth is a small signal number at unity gain and it describes a different behaviour. For a multiplexed front end the settling figure is the one that matters, because the channel has to be inside the error band before the converter starts its acquisition window, and the two numbers get added: 0.6 microseconds of settling plus the converter's track time, against the sample period. A 250 kSPS converter has 4 microseconds per conversion, so one channel of this amplifier plus the converter uses about 1.5 of them and two channels do not fit.
Drift is 25 microvolts, and the bias current is 0.5 microvolts
The 0.2 microvolts per degree C maximum drift over a 125 C span is 25 microvolts input referred, which is 2.5 millivolts at the output of a gain of 100 stage. The 500 pA of bias current flowing through a 1 Mohm source is 0.5 microvolts, and through 10 Mohm it is 5 microvolts, so the bias current only matters above roughly 5 Mohm. The 94 dB of common mode rejection at a gain of 1 is 20 microvolts per volt of common mode, against 100 microvolts per volt at the 80 dB figure, and that fivefold difference is the reason the B grade exists. A buyer who needs the tighter offset drift and rejection has to order the B grade, because it is a separate order code and not a selection at test.
| Parameter | Published value | What it decides |
|---|---|---|
| Voltage noise | 3.2 nV per root hertz maximum at 1 kHz | 0.32 microvolts over 10 kHz |
| Current noise | 200 fA per root hertz at 1 kHz | Matters above 100 kohm sources |
| Bandwidth | 10 MHz at gain 1, 2 MHz at gain 100 | Small signal, not settling |
| Settling | 0.6 microseconds to 0.001 percent at gain 10 | About a 3 MHz pole |
| Offset drift | 0.2 microvolts per degree C maximum, B grade | 25 microvolts over 125 C |
| Gain drift | 1 ppm per degree C maximum at gain 1 | Set by the internal resistors |
| Common mode rejection | 94 dB minimum at gain 1, B grade | 20 microvolts per volt |
| Bias current | 500 pA maximum | 0.5 microvolts at 1 Mohm |
| Supply | 2.3 mA maximum, plus or minus 2.5 to 18 V | 69 mW at plus or minus 15 V |
Does the 40 V input protection survive a live fault?
The specification is that an input can sit 40 V beyond the opposite supply rail without damage, which is the case that matters when a sensor is powered while the amplifier is not, or when a transducer is plugged in with the equipment running. It is a protection rating, not an operating range: the part still has to stay inside its supply rails in normal use, and the 40 V is what keeps a fault from destroying it rather than what it measures. The same protection is why the input noise stays low, since a series resistor in front of the input would add its own thermal noise and defeat the purpose of a 3.2 nV part.
Can one resistor set the gain accurately enough?
The internal resistors are trimmed to 1 ppm per degree C of gain drift at a gain of 1, and the external resistor sets the absolute gain, so its own tolerance and tempo are inside the gain error. A 0.1 percent resistor buys a 0.1 percent gain, and the same 0.1 percent resistor with a 100 ppm per degree C tempo adds 1 percent of gain error over a 100 C rise. The 0.6 microsecond settling and the 2 MHz bandwidth at a gain of 100 already put this part in the fast instrument class, and the resistors around it are the part of the circuit that determines whether the accuracy claim survives production. The amplifier range is on the amplifier cross reference, the patient monitoring and imaging cases are on the medical device components page, and the complete index is the analog and mixed-signal index.
Request Quote — In Stock, 100% New & Original, Full Warranty