AD694BRZ
Product Specifications
AD694BRZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD694BRZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AD694BRZ: Tighter Reference, Same 4 to 20 mA Loop
The AD694BRZ is the B grade of the current loop transmitter, and the difference from the A grade sits almost entirely in the reference and the transfer accuracy rather than in the loop behaviour. The output is still 4 to 20 mA with 0.002 percent typical nonlinearity, the input spans are still 0 V to 2 V and 0 V to 10 V by pin strapping, the compliance still reaches to within 2 V of the supply, and the alarm and 4 mA test functions are unchanged. What the B grade adds is an on board reference held to a tighter tolerance, which matters when the transmitter powers the sensor bridge and therefore sets the excitation as well as the scale. A bridge excited from a reference that is 0.5 percent low produces a reading that is 0.5 percent low, and no amount of downstream calibration recovers it because the sensor output itself moved.
Published values
| Parameter | Value |
|---|---|
| Output | 4 mA to 20 mA current loop |
| Input spans | 0 V to 2 V and 0 V to 10 V, pin selectable |
| Reference | 2.000 V or 10.000 V, B grade tolerance tighter than A |
| Nonlinearity | 0.002 percent typical |
| Compliance | To within 2 V of the positive supply |
| Alarm | Open collector, open wire and noncompliance |
| 4 mA test | Zero current can be switched with a TTL input |
| Dissipation | External pass transistor option |
| Body | Surface mount, R suffix, B grade |
When the grade is a measurement decision, not a price decision
In a transmitter that is fed by a 0 V to 2 V signal from an external source, the reference accuracy only affects the internal calibration and can be trimmed at the factory. In a transmitter that excites its own bridge, the reference is the measurement: a 0.1 percent reference error becomes a 0.1 percent span error that no zero trim touches, and it drifts with the reference over temperature. That is the case the B grade is specified for, and it is worth stating plainly to a buyer who is comparing the two line items on price alone, because the cheaper grade shifts the calibration burden into the field.
Loop behaviour is unchanged across grades
Because both grades share the output stage, the compliance behaviour, the alarm threshold and the settling time are the same, so a program that has already qualified the loop with the A grade can move to the B grade without repeating the loop tests. The 4 mA zero test and the alarm pin remain the field diagnostic, and the external pass transistor remains the thermal answer. That is the useful property of a grade change inside one family: the qualification work transfers and only the calibration step changes.
Sourcing notes
The B grade is a narrower line than the A grade, and the surface mount body is the common order code. Where the B grade is unavailable, the A grade will run the same loop with a calibration step, provided the reference is not exciting the sensor. Where neither is available, a discrete transmitter built around an op amp and a reference is the fallback, and it costs board area and a temperature coefficient that has to be characterised. The amplifier cross reference lists the transmitter families we supply, the incoming inspection plan covers how a batch is checked against its grade, and the lead time page shows current stock positions.