Contact Us
  • Home
  • COMPONENTS
  • Isolated Amplifiers for Shunt and Voltage Sensing

Isolated Amplifiers for Shunt and Voltage Sensing

Isolation amplifiers that pass a millivolt shunt signal or a bus voltage across a certified barrier. Working voltage, withstand voltage and drift are all quoted per part number. Parts from TI, Analog Devices, Broadcom and Skyworks are supplied for drives, inverters and battery systems. Cross reference and long term supply are checked before quoting.
quote now

Product Specifications

Product Overview

A shunt resistor in a motor phase sits at a common mode voltage that swings with the switching node, often through 400 or 800 V in a few tens of nanoseconds. The amplifier has to pass the hundred or so millivolts across that shunt while ignoring the swing, and it has to keep the low side safe if the high side fails. That is the whole job of an isolation amplifier, and the reason the barrier rating, not the gain accuracy, is the first column in most selection tables.

Three constructions are in volume use. Capacitive sigma delta parts (AMC1200, AMC1300, AMC1301, AMC1311, ISO224, Si8920, ACPL-C79B) put a small modulator on the high side and send a bit stream across a silicon dioxide barrier, which gives the lowest drift and the tightest part to part matching. Optically coupled parts (HCPL-7840) use an LED and a matched photodiode pair, and the LED aging shows up as slow gain drift rather than as a hard failure. Transformer coupled parts (AD202, AD210, ISO124) carry both signal and power across the barrier, which removes the isolated supply but limits the signal bandwidth to a few kilohertz up to about fifty.

The accuracy numbers decide the part, not the headline isolation figure. The AMC1301 is specified with 0.2 mV maximum offset, 3 microvolts per degree of offset drift, 0.3 per cent gain error and 50 ppm per degree of gain drift at a fixed gain of 8.2, so a 1 milliohm shunt at 100 A produces 100 mV and the offset is 0.2 per cent of that reading. The AMC1200 quotes 1.5 mV of offset for a much lower price, which is 1.5 per cent of the same reading; the choice between them is an accuracy target, not a brand preference. The ACPL-C79B and the Si8920 sit at 0.4 mV and 0.2 mV with 200 kHz and 750 kHz of bandwidth, which is what a short circuit protection loop needs.

Two figures are read wrongly every week. A 5000 Vrms UL1577 rating is a one minute withstand test, while the working voltage for continuous operation on the same part is 1000 to 1500 Vrms, and long term insulation life is quoted against that lower number. The second is the supply: a capacitive or optical part needs an isolated supply on the high side, usually a small push pull transformer driver with a rectifier, and a part quoted without that supply in the bill of materials will not run. The transformer coupled AD202 carries its own converter from a single 15 V rail, which is why it is still used in instrument and process channels where 5 kHz of bandwidth is enough.

Key Specifications

Figures below are the data sheet values for the isolated side of each part. Where a value is not published for that part number the cell says not quoted rather than carrying a figure from a neighbouring part.

ParameterAMC1300AMC1301ISO224ISO124HCPL-7840ACPL-C79BSi8920B
Input rangeplus or minus 250 mVplus or minus 250 mVplus or minus 12 Vplus or minus 10 Vplus or minus 200 mVplus or minus 200 mVplus or minus 200 mV
Fixed gain8.28.20.33188.28.1
Withstand isolation5000 Vrms5000 Vrms5000 Vrms1500 Vrms3750 Vrms5000 Vrms3750 Vrms
Working isolation1500 Vrms1000 Vrms1500 Vrms1500 Vrmsnot quoted1230 Vpeaknot quoted
CMTI minimum15 kV per microsecond15 kV per microsecond15 kV per microsecondnot quoted15 kV per microsecond15 kV per microsecond75 kV per microsecond
Offset maximum0.2 mV0.2 mV5 mV50 mV0.3 mV0.4 mV0.2 mV
PackageSOIC-8 DWVSOIC-8 DWVSOIC-8 DWVPDIP-16 and SOIC-28DIP-8stretched SO-8DIP-8 and SOIC-16

Included Models and Order Codes

Order codes in the table below are the versions most often asked for by name. The plain suffix on a TI part is the tube version, the R suffix is tape and reel, and the E suffix on a Broadcom part means lead free.

Part NumberInputGainIsolationPackage
AMC1200BDWVRplus or minus 250 mV84250 Vpeak basicSOIC-8
AMC1300BDWVRplus or minus 250 mV8.25000 Vrms reinforcedSOIC-8
AMC1301DWVRplus or minus 250 mV8.25000 Vrms reinforcedSOIC-8
AMC1311BDWVR2 V15000 Vrms reinforcedSOIC-8
ISO224BDWVRplus or minus 12 V in, plus or minus 4 V out0.335000 Vrms reinforcedSOIC-8
ISO124Uplus or minus 10 V11500 VrmsSOIC-28
ISO124Pplus or minus 10 V11500 VrmsPDIP-16
AD202JYplus or minus 5 V output1 to 100 by external resistors2000 VpeakSIP-10
HCPL-7840-000Eplus or minus 200 mV83750 VrmsDIP-8
ACPL-C79A-000Eplus or minus 200 mV8.2 at 1 per cent5000 Vrmsstretched SO-8
ACPL-C79B-000Eplus or minus 200 mV8.2 at 0.5 per cent5000 Vrmsstretched SO-8
Si8920BC-IPplus or minus 200 mV8.13750 Vrmsgull wing DIP-8
Si8920BD-ISplus or minus 200 mV8.15000 Vrmswide body SOIC-16
Si8920AC-IPplus or minus 100 mV16.23750 Vrmsgull wing DIP-8

The 100 mV and 200 mV input versions of the Si8920 use the same die with different internal gain, so the input range can be matched to the shunt without changing the footprint. The AMC1311 and the ISO224 cover voltage sensing rather than shunt sensing: the first takes 2 V directly and the second takes plus or minus 12 V, which suits a resistor divider on a high voltage rail.

Key Features

Input range matched to a milliohm shunt – plus or minus 250 mV full scale on the AMC parts and plus or minus 200 mV on the HCPL, ACPL and Si parts, so a 1 milliohm shunt at 100 A uses the whole input range instead of the first tenth of it.

Working voltage quoted beside the withstand voltage – a 5000 Vrms UL1577 figure is a one minute test, while the continuous working voltage on the same part is 1000 to 1500 Vrms, and both numbers appear in the table.

Drift that decides the last digit – 3 microvolts per degree of offset drift and 50 ppm per degree of gain drift on the AMC1301 and the ACPL-C79B keep a 12 bit reading stable across a cabinet that swings from minus 20 to 70 C.

Common mode transient immunity for inverter edges – 15 kV per microsecond minimum on most of the range and 75 kV per microsecond on the Si8920, which is the figure that keeps the output from glitching when the far side of the bridge switches.

Fixed gain removes the trim – the 8 to 8.2 parts are set at the wafer to between 0.3 and 0.5 per cent, so a channel is calibrated by one resistor value and one software constant rather than by a potentiometer on every board.

Transformer coupled parts for bipolar signals – the AD202 and the AD210 carry power across the barrier from a single 15 V rail and pass plus or minus 10 V signals, at 5 kHz to 20 kHz of full power bandwidth, for process and instrument channels that do not need speed.

Applications

These parts are quoted for products that measure a current or a voltage on the far side of a barrier, typically where:

Servo and pump drives – phase current is read across a shunt on the low side of the bridge or in the emitter path, and the amplifier has to survive the switching node dv/dt while the control loop closes in under 100 microseconds.

Battery and DC bus voltage sensing – an 800 V pack or a 400 V DC link is divided down to 2 V or 12 V and read through the AMC1311 or the ISO224, which keeps the divider string short and the creepage inside the package.

Grid tied inverters and solar MPPT – string current and grid voltage are measured on the hot side, and the barrier rating has to satisfy the safety file rather than only the bench, so the working voltage is quoted with the part.

Most of these channels end up on one mixed signal board, so the isolation amplifier is quoted together with the isolated gate driver, the isolated supply and the connector that carries the barrier. That board is the one we build as the SUPERB PCB and the SUPERB PCBA, which means the amplifier, its supply and its creepage are checked on the same drawing instead of in three separate quotes.

Sourcing and Cross-Reference

The first check is the direction of the signal and the supply that comes with it. A capacitive or optical part needs an isolated high side supply, and that supply has to be in the bill of materials before the amplifier is chosen, because a 5 V rail that comes from the control side cannot power the high side of the barrier. The second check is the input range against the shunt: a 250 mV part on a 50 mV shunt throws away two bits, and a 100 mV part on a 200 mV shunt clips on a fault.

The second half of the check is the cross reference, and it is where most replacement quotes are lost. The AMC1200 family has been superseded by the AMC1200C and the AMC1300 class, which keeps the footprint but changes the offset and the working voltage, so a drop in swap on the same board has to be checked against the creepage and the certification file, not only against the pinout. The comparison method we use is on amplifier cross reference, and the wider list of replacements sits on obsolete part cross reference hub.

Long term supply is the third check. Several of these parts are mature rather than new, and the last time buy date on a mature isolation amplifier is decided by the fab rather than by the distributor, so a buffer of two to three years of demand is normal for a product with a ten year service life. Our component obsolescence management page describes how a last time buy is sized, and the parts that share a board with them are listed under digital isolators and isolated gate drivers. For volume builds, SUPERB Assembly support covers the creepage slot under the package, the isolated supply and the divider string.

Q: Can you supply pin to pin replacements for discontinued isolation amplifiers?

A: Yes. Send the part number, the pinout you are locked to and the working voltage in your safety file. The SUPERB Tech team checks offset, gain, working voltage and creepage against the maker data sheet and replies with a replacement plus the differences that need a board change.

Q: Which part should be used to sense an 800 V bus?

A: The ISO224 is the usual answer because it takes plus or minus 12 V single ended and gives a plus or minus 4 V differential output at a fixed gain of 0.33, so a divider sets the range and the working voltage stays at 1500 Vrms. The AMC1311 with a 2 V input does the same job where a smaller divider ratio is acceptable.

Q: Do you hold both the 100 mV and the 200 mV input versions?

A: Both input ranges are quoted for the Si8920 and the ACPL parts, and the AMC1200, AMC1300 and AMC1301 cover the 250 mV range. Availability is confirmed per order code, because the tape and reel and the tube versions move on different schedules.

Why Buyers Source Isolation Amplifiers Through SUPERB

  1. Working voltage and withstand voltage are both quoted: the barrier figure that goes into a safety file is the continuous working voltage, and it is given per part number instead of being left to the market name.
  2. Offset and drift stated as maximums: the figures in the table are the maximum over the temperature range, because a typical number cannot be used to size a shunt or to set a fault threshold.
  3. Supply side checked with the part: a capacitive or optical part is quoted together with the isolated supply it needs on the high side, so the bill of materials is complete at the quotation stage.
  4. Obsolete and allocated parts handled as a supply task: mature isolation amplifiers are quoted with a last time buy option and a dated replacement, rather than with a shrug at the end of the year.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with current sense amplifiers and shunt monitors, instrumentation amplifiers for bridge signals, digital isolators, isolated gate drivers and IGBT and SiC power devices.