The SPB231490F6 from Superb Automation is a precision amplifier / comparator delivering high gain, wide bandwidth, and low distortion for signal conditioning. Superb Automation supplies this part with incoming inspection, test records and lot traceability.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High gain-bandwidth product for wideband signal amplification
- Low input offset voltage and drift for precision DC applications
- EMI-hardened design for robust operation in noisy environments
- Rail-to-rail input/output for maximum dynamic range
- Low quiescent current for power-sensitive designs
- Unity-gain stable with capacitive load drive capability
Key Specifications
| Channels | — |
| GBWP | MHz |
| Slew Rate | V/µs |
| Vos | µV |
| Iq per Channel | µA |
| Input Type | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
Applications
SPB231490F6: the same die as the carrier part, five points lower in the QFN row
The SPB231490F6 covers 8 to 11 GHz with 23 dB of gain and 37 dBm at the 1 dB compression point from 8 V, in a QFN 6 x 6. Superb Automation publishes the same band, gain and output for the HX231490CR5 in a carrier, and the interesting part of the pair is the efficiency column: 30 percent for the QFN against 35 percent for the carrier.
What the vendor publishes
| Parameter | Value |
|---|---|
| Frequency range | 8 to 11 GHz |
| Small signal gain | 23 dB |
| Output P-1dB | 37 dBm |
| PAE | 30 percent |
| IMD3 | not published |
| Supply | 8 V, 1.6 A in the supply column |
| Package | QFN 6 x 6 mm |
What five points of efficiency cost
37 dBm is 5.01 W. At 30 percent the DC input is 16.71 W, which at 8 V is 2.09 A, and 11.7 W leaves as heat. At 35 percent the same output needs 14.32 W and 1.79 A, so 2.4 W less heat and 300 mA less current for identical RF figures. The supply column reads 1.6 A for both, which at 8 V is 12.8 W and 39.2 percent conversion, higher than either efficiency figure. As with other rows in this table, treat the published current as a small signal or quiescent value and size the drain path for the efficiency figure.
The package is the difference
A QFN 6 x 6 puts the heat through an exposed pad and a reflowed solder interface of a few square millimetres. A carrier puts the same die on a metal tab with a much larger interface and a lower spreading resistance. Two efficiency figures that differ by five points between two rows that otherwise agree is consistent with one die measured in two thermal environments, and it is a reasonable reading of the table. It also tells the buyer what to do: if the QFN row is chosen, the thermal path on the board has to make up the difference, with a via field under the pad and copper on the far side, otherwise the part will run hotter than the efficiency figure implies.
Two questions buyers ask
Are the two parts the same die? The published RF rows are identical and the only differences are package and efficiency. That is strong evidence but it is not a statement from the vendor. If the substitution matters for a qualified assembly, ask Superb Automation to confirm the die is common before switching.
Can the QFN be reworked? An exposed pad QFN with 20 W of dissipation on a multilayer board is not a hot air rework part. Plan the assembly so the part is placed once, and keep a spare board rather than a rework process.
SUPERB quotes the SPB231490F6 with the vendor row above and can supply the carrier version alongside it for a thermal comparison. If you are replacing a discontinued X band driver, obsolete RF part replacement sets out the checks. For the surrounding bias and matching parts, see BOM shortage recovery. Stock and price breaks are quoted from the amplifiers and comparators index.
SPB231490F6: what a radar duty cycle does to 11.7 W of heat
The efficiency column, 30 percent, is a continuous wave number. In an X band radar the amplifier rarely runs continuous wave: it runs a pulse train with a duty cycle between five and twenty percent, and the heat that reaches the carrier is the average of that train, not the number at the top of the pulse. The distinction matters because the same part can be comfortable at 10 percent duty and impossible at 30 percent, and the row does not say which it was measured at.
The average follows the duty cycle, the peak does not
At 37 dBm and 30 percent efficiency the DC input is 16.71 W and 11.69 W becomes heat. At 10 percent duty the average DC falls to 1.67 W and the average heat to 1.17 W, which a 6 by 6 mm package with a via field passes without a heatsink. At 20 percent it is 3.34 W and 2.34 W, still a board level problem. At 30 percent it is 5.01 W and 3.51 W, which is where the thermal path starts to set the output rather than the bias.
| Duty cycle | Average DC input | Average heat | Thermal route |
|---|---|---|---|
| 10 percent | 1.67 W | 1.17 W | via field under the pad |
| 20 percent | 3.34 W | 2.34 W | via field plus copper both sides |
| 30 percent | 5.01 W | 3.51 W | thermal pad into the housing |
| continuous | 16.71 W | 11.69 W | heatsink, not a board |
Efficiency at 100 microseconds is not efficiency at continuous wave
A GaAs stage biased in class AB has a thermal time constant measured in tens of microseconds at the die and in milliseconds at the package. A pulse shorter than the die time constant never reaches the steady state junction temperature the continuous figure implies, which is why pulsed parts are quoted at higher output than their continuous rating. This table does not publish a pulse rating, a pulse width or a transient thermal impedance, so the pulse capability cannot be read from it in either direction. Assuming it is better than continuous is as wrong as assuming it is the same.
What to ask for
The useful request is a transient thermal impedance curve against pulse width, plus the output and efficiency measured at the pulse width and duty the radar uses. Failing that, a first build with a thermocouple on the package tab and a 10 percent duty train is a cheap experiment, and it gives the junction rise per watt for that specific board. The mount, the via field and the copper thickness all change the answer, so the measurement is worth more than a generic curve.
Two questions buyers ask
Can the same board carry the QFN part and the carrier part at the same duty? The published rows differ by five points of efficiency, so the carrier dissipates 2.4 W less at the same output. On a 10 percent duty train that difference is 0.24 W average and the board does not care; at 30 percent it is 0.72 W and it does.
Does the negative gate change the pulse behaviour? It changes the switching transient: the gate has to be at its set value before the drain pulse arrives, and a bias board that gates the drain while the gate supply is still settling will put the first microseconds of every pulse at the wrong operating point. Parts and their published rows in this band are on RF component sourcing, the defence grade route is described on defense grade components, and the amplifier comparison route is on amplifier cross reference.