Contact Us

TJA1021BT/0Z

Brand: NXP Semiconductors
NXP Semiconductors TJA1021BT/0Z is a mcu & embedded component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TJA1021BT/0Z — MCU & Embedded Processors | Superb Automation

TJA1021BT/0Z

NXP Semiconductors — MCU & Embedded Processors

Product Overview

The TJA1021BT/0Z from NXP Semiconductors is a microcontroller / embedded processor engineered for real-time control, signal processing, and connectivity. NXP Semiconductors provides secure connectivity solutions, embedded processors, and automotive-grade MCUs for edge computing.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • ARM Cortex / RISC-V / proprietary core with high-performance real-time processing
  • Integrated flash memory and SRAM for efficient code execution
  • Rich peripheral set: UART, SPI, I2C, ADC, timers, PWM
  • Low-power modes for battery-operated and energy-sensitive applications
  • Hardware security features: secure boot, crypto accelerator, TRNG
  • Extensive development ecosystem with IDE, HAL, and RTOS support

Key Specifications

Core—
Max FrequencyMHz
FlashKB
SRAMKB
GPIO—
ADCbits
Interfaces—
Supply VoltageV
Operating Temp°C
Package—

Applications

Industrial Motor Control IoT Edge Nodes Consumer Electronics Automotive Body Control Smart Home & Appliances Medical Portable Devices

Request Quote — In Stock, 100% New & Original, Full Warranty

TJA1021BT/0Z: SO8 LIN transceiver, B variant with the 20 kBd normal slope

TJA1021BT/0Z is the B variant of the SO8 LIN transceiver, set to the normal slope for 20 kBd in the TJA1021 LIN transceiver line, described by Rev 4 family document. It is the B member of the pair added in the last revision of the TJA1021 document, where A is the low slope 10.4 kBd code and B is the normal slope 20 kBd code. Electrically it matches the /20 code, and the ordering table lists the two side by side with the same body and the same rate.

Order code and package

Order codeTJA1021BT/0Z
Variant function on pin 5SLP_N input with an INH output; the B suffix is the normal slope variant added with the A code
PackageSO8, 3.9 mm body width, 8 pins
ProtocolLIN 2.0, 2.1, 2.2, 2.2A, SAE J2602 and ISO 17987-4:2016 (12 V)
Maximum data rate20 kBd on the /20 and B codes and 10.4 kBd on the /10 and A codes
Supply voltage on VCC5.5 to 27 V on VBAT
Logic supply on VIOnot present; inputs are compatible with 3.3 V and 5 V logic
Temperature rangeminus 40 to plus 150 C virtual junction
QualificationAEC-Q100
DatasheetRev 4 family document

Electrical parameters that decide the application

Bus fault voltageminus 40 to plus 40 V on LIN and VBAT as a limiting value
Supply currentSleep mode battery current 2 to 10 microamps with the LIN pin at battery and the wake pin high
Electrostatic dischargeplus or minus 6 kV IEC 61000-4-2 on LIN, VBAT and WAKE_N
Thermal resistance93 K/W junction to ambient in the SO8 body
Wake and diagnostic pinsSLP_N input, INH output, local and remote wake-up with source recognition, and an integrated responder termination
Bus pinsCANH and CANL, differential, with the recessive level set by the on chip driver or by a SPLIT output where the code carries one
Logic levelsinputs compatible with 3.3 V and 5 V devices
Behaviour with the supply offthe transceiver disengages from the bus so an unpowered node does not load the network
ProtectionTXD dominant time-out, undervoltage detection and thermal shutdown are named in every document in this family
Ordering stringthe suffix after the slash carries the body, the packing and the variant, so it has to be quoted in full on a purchase order

Points to check before this part goes on a BOM

The document lists TJA1021BT with the /20 codes as the normal slope group at 20 kBd, and TJA1021AT with the /10 codes as the low slope group at 10.4 kBd. The ordering table gives no other electrical difference between the B code and the older /20 code.

The variant letter is worth reading on the reel rather than on a distributor description, because a line that is set to the wrong slope still works on the bench and only fails the emission test or the J2602 conformance run.

Sleep current is 2 to 10 microamps, the same as the rest of the line, so a B code node sits on a vehicle battery for months. That figure is what makes a LIN cluster viable at all, since a node with a milliamp sleep current would flatten a battery in weeks.

The integrated responder termination removes the external 30 kohm resistor and its diode, and the WAKE_N input with source recognition tells the controller whether the wake came from the bus or from a local switch.

The LIN pin is short circuit proof to battery and ground and carries plus or minus 6 kV IEC 61000-4-2, the same as the other codes. On a door module where the bus runs beside a motor, that is the rating that gets tested in the field.

Pin compatibility with the TJA1020 and MC33662(B) is stated for the whole line, so the B code drops onto the same footprint. What changes is the slope and the marking, and a board that carries both codes on the same assembly needs a line side check rather than a visual one.

Where this order code fits

It is the code that arrives when a board is refreshed onto the current ordering table, and it runs the same 20 kBd nodes as the older /20 code. Boards weighing one CAN transceiver against another start from our CAN Bus Transceiver Selection page, and boards replacing a part that has gone end of life start from the Incoming Inspection Plan page.

Questions buyers ask

What is the difference between TJA1021BT and TJA1021T/20? Both are normal slope parts at 20 kBd in the same SO8 body. The ordering table lists them together and gives no other electrical difference; the variant letter is the later marking.

Is it the low slope variant? No. The A code is the 10.4 kBd low slope part. B is the 20 kBd normal slope part.

Does it need an external termination? Not as a responder. The 30 kohm responder termination is integrated, and only a commander node needs its own pull-up and diode.

SUPERB holds and sources NXP interface lines including this order code for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated. When a line is changing, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.