TPS7B8350QDCYRQ1
Product Specifications
TPS7B8350QDCYRQ1
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS7B8350QDCYRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS7B8350QDCYRQ1: 5 V, 150 mA and only 18 uA of standing current
The TPS7B8350QDCYRQ1 is the 5 V member of the TPS7B83-Q1 line, a 150 mA regulator with an 18 uA typical quiescent current, a 3 V to 40 V input window and 42 V of transient tolerance. Accuracy is plus or minus 1 percent, which is a full step tighter than the older 40 V parts, and the SOT-223 body gives the tab a place to put its heat. The part is AEC-Q100 grade 1 with a junction range to 150 C.
The transient behaviour is the other half of the case. Output deviation is plus or minus 2 percent during a cold crank, and the architecture is built to minimise overshoot when the input recovers from dropout, which is the moment a 5 V rail usually pushes a spike into the logic behind it. Current limit is 220 mA to 260 mA, a brickwall rather than a foldback, so a short holds the rail at a bounded current instead of oscillating.
Key electrical data for the 5 V part
| Input range | 3 V to 40 V, 42 V maximum, with 45 V transients tolerated |
| Output | 5.0 V fixed at plus or minus 1 percent over line, load and temperature |
| Output current | 150 mA, current limit 220 mA to 260 mA |
| Quiescent current | 18 uA typical at light load, which is what keeps a parked module alive |
| Dropout | 230 mV maximum at 150 mA for the 3.3 V option, similar for the 5 V point |
| Transient | plus or minus 2 percent deviation during a cold crank and on recovery from dropout |
| Junction range | minus 40 C to 150 C, grade 1 qualified |
Package, marking and reel data
| Body | SOT-223 DCY, 4 pins, tab soldered to the board, 330 mm carrier |
| Reel | 2500 pieces, large tape and reel, quadrant Q3 |
| Finish and moisture | SN, level 2, 260 C peak reflow, one year floor life |
| Marking | 7B8350 |
| Suffix rows | M3 and W rows carry the same die with a different marking convention and the same reel size |
Where a 1 percent 5 V rail earns its cost
CAN transceivers, sensor supply pins and always-on logic all tolerate a few percent, so why pay for 1 percent? Because the 5 V rail often feeds a reference or a ratiometric sensor, and a 3 percent window on a 5 V rail is 150 mV of error that lands directly in the measurement. A 1 percent part costs little more than a 3 percent one and removes that term from the calibration, which is the cheaper place to remove it.
The 18 uA quiescent current then decides whether the module can stay connected. A 40 uA drain on a 60 Ah battery is 1 mAh per day, which is acceptable over a two week parking period; a 300 uA drain is not. The TPS7B83-Q1 sits in the first category, and that is why it turns up in body modules, gateways and battery management units that are never really switched off. The 3 V to 42 V window also means the same code survives a jump start and a load dump without a clamp, which removes two parts from the front end of the board. The 1 percent window then holds that same rail steady through the event, so the logic behind it never sees the transient that the protection parts were there to absorb. A clamp is still worth keeping on the input for the load dump itself, but it no longer has to protect a 40 V part from a 60 V event.
Buyer questions on the TPS7B8350QDCYRQ1
What are the M3 and W suffix rows? They are the same die and the same reel size with a different part marking convention, used where a customer's traceability system expects a specific code. Electrically the rows are equivalent, so the choice is made on the marking rule of the assembly house.
Is the part stable without an output capacitor? No. The data sheet requires a ceramic output capacitor for stability, and the transient figures assume it. Removing it is the most common cause of a rail that looks fine at room temperature and oscillates cold.
How does the part behave when the input is below the output? It enters dropout and the output follows the input down, with the recovery overshoot bounded by the architecture. That is the behaviour that keeps a 5 V rail from spiking when a crank event ends.
Buying this regulator through a component supplier
The suffix rows are the trap in this family: three codes, one die, and a line that reads the wrong column will reject a good reel. Our power management cross reference prints the marking next to each code. Where a customer is qualifying a second body, supplier quality audit covers what the incoming inspection should confirm.