TPS629203DRLR
Product Specifications
TPS629203DRLR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS629203DRLR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS629203 300 mA buck from a 3 V to 17 V rail
The TPS629203 is a 300 mA synchronous step down converter that takes 3 V to 17 V in and regulates an output from 0.4 V to 5.5 V. It is built for the small housekeeping rails on a 12 V or 24 V board: a sensor supply, a bias rail for an amplifier, a reference for an analogue front end. The switch resistances are 250 milliohm on the high side and 85 milliohm on the low side, the quiescent current is 4 microamp typical, and the switching frequency can be set to 1 MHz or 2.5 MHz, which is the choice between efficiency and a small inductor.
The output can be set two ways. An external divider on the FB pin covers 0.6 V to 5.5 V with a 0.6 V reference, and the internal divider selected by the VSET pin covers eighteen preset values between 0.4 V and 5.5 V. The internal option is the one that matters on a board with several variants, because a preset level needs no divider and no tolerance term, and the level is chosen by a resistor that is read once at start up.
The current limits are modest by the nature of the part rather than by accident: the high side switch limits at 0.8 A minimum, 1.1 A typical and 1.4 A maximum, and the low side at 0.5 A, 0.9 A and 1.3 A, with a sink limit for negative current between 0.8 A and 1.2 A. On a 300 mA part those windows are wide, which is what allows a 12 V to 3.3 V conversion to survive a cold start and a short circuit without a fold back that never recovers.
Key parameters from the SLVSGE2 document
| Input range | 3 V to 17 V, with UVLO hysteresis of 200 mV |
| Output range | 0.4 V to 5.5 V, eighteen preset values through VSET or a divider on FB |
| Output current | 300 mA rated |
| Switching frequency | 1 MHz or 2.5 MHz selectable |
| High side resistance | 250 milliohm |
| Low side resistance | 85 milliohm |
| Current limit | High side 0.8 A to 1.4 A, low side 0.5 A to 1.3 A, sink limit 0.8 A to 1.2 A |
| Quiescent current | 4 microamp typical in power save mode with no load |
| Shutdown current | 0.25 microamp typical and 1.5 microamp maximum |
| Reference | 0.6 V on the external divider configuration |
| Thermal shutdown | 170 degrees junction, junction range minus 40 to plus 125 degrees |
| Package | Six pin DRL SOT-563 body |
What a 17 V input means for the parts around it
A 17 V rating is not a 24 V rating, and the distinction decides whether the part goes on a 12 V rail or on a 24 V rail. On a 12 V automotive rail a load dump is clamped upstream of the converter, so 17 V is enough; on an industrial 24 V rail the converter sees the full rail plus the tolerance, and 17 V is not enough. Getting this wrong is the most common reason a housekeeping converter fails in the field, and it fails at power on rather than gradually.
At 1 MHz the inductor is in the 10 microhenry class and the ripple at 300 mA is comfortable. At 2.5 MHz the inductor can drop to 4.7 microhenry and the converter becomes small enough to sit next to the load, which matters when the rail feeds an analogue block that cannot tolerate a long trace. The price is a higher switching loss, which at 300 mA is still small compared with the conduction loss at the bottom of the input range.
The automatic efficiency enhancement mode is worth knowing about. Below a few milliamps the part reduces its own switching frequency and quiescent current rather than entering a fixed burst pattern, so a rail that supplies a sensor in a standby state still holds regulation without the ripple that a burst mode produces. On an analogue rail that ripple is the difference between a usable measurement and a noisy one.
Where this part fits
Sensor and amplifier bias rails on 12 V industrial boards, gate drive supplies, isolated converter housekeeping, telecom line cards and any board where 300 mA is enough and the input is far above the output. Our cross reference notes are at power management cross reference and the substitution check is at how to verify a drop in replacement.
What to check before a purchase order
Check the input rating against the rail, not against the nominal voltage. This part is rated 17 V, the 629210 is also 17 V, and the 18 V class belongs to a different family. A 24 V rail with a 10 per cent tolerance is 26.4 V and will destroy the part on the first power on, so the number on the data sheet front page has to be compared with the worst case rail rather than with the label.
Check the VSET resistor or the divider, because the two configurations are not interchangeable on one board. A board built for a preset level with the divider removed will not regulate if it is populated with the divider version, and the symptom is an output that sits at the reference rather than at the intended rail. The receipt check we run is at incoming inspection plan.
Questions that come up on this part
Can the part deliver 300 mA at 17 V input and 0.4 V output, is a question that comes up on core rails. The current limit allows it, but at that conversion ratio the duty cycle is 2 per cent, the minimum on time of about 40 nanoseconds becomes the limiting factor, and the ripple and the switching loss dominate. A rail that needs a very low output from a very high input is better served by a two stage conversion.
The other question is whether the 1 MHz and 2.5 MHz settings can be changed at run time. They cannot, because the frequency is set by a pin at start up. A board that has to move between the two for emissions reasons carries both options as separate order codes rather than a register write.