TPS564208DDCR
Product Specifications
TPS564208DDCR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS564208DDCR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS564208DDCR: 4 A synchronous buck converter from 4.5 V to 17 V with a 560 kHz fixed frequency
TPS564208DDCR is a 4 A synchronous buck converter with 50 mOhm and 22 mOhm switches, internally compensated and fixed at 560 kHz, in a six pin SOT-23 body in a SOT-23 body of 6 pins. The TPS564208 takes 4.5 V to 17 V in and delivers 4 A through a 50 mOhm high side and a 22 mOhm low side switch. It runs at a fixed 560 kHz in continuous conduction, has a 760 mV feedback threshold with 1.6 percent accuracy at 25 C, starts into a pre-biased output, and provides cycle by cycle overcurrent limit with hiccup on a hard fault. Soft start is 1 ms, shutdown current is below 10 uA, and the body is a six pin SOT-23.
Order code and package
| Order code | TPS564208DDCR |
| Input voltage | 4.5 V to 17 V |
| Output current | 4 A |
| Output voltage | 0.76 V to 7 V, set by a divider |
| Integrated switches | high side 50 mOhm, low side 22 mOhm |
| Switching frequency | 560 kHz fixed |
| Feedback threshold | 760 mV, 745 mV to 775 mV over temperature |
| Feedback accuracy | 1.6 percent at 25 C |
| Soft-start time | 1 ms |
| Shutdown current | 0.9 uA typical, 5 uA maximum |
| Package | 6 pin SOT-23 |
| Document | SLVSDG0B, March 2016, revised December 2017 |
Electrical parameters that decide the application
| Current limit | 4.2 A minimum, 6 A typical, 7.7 A maximum |
| Input quiescent current | 640 uA typical, 820 uA maximum at 12 V in |
| Enable high threshold | 1.6 V minimum |
| Enable low threshold | 0.8 V maximum |
| Enable pin resistance | 225 kOhm minimum, 425 kOhm typical, 900 kOhm maximum |
| Input UVLO | 3.3 V minimum falling, 3.6 V maximum |
| Wake-up input voltage | 4 V minimum, 4.3 V maximum |
| Output undervoltage protection | hiccup at 65 percent of nominal |
| Junction range | -40 C to 125 C |
| Mode | continuous conduction, forced by the part |
| Thermal resistance | quoted for the SOT-23 body on a two layer copper pour |
| Feedback leakage | 0.1 uA maximum at 0.8 V |
Points to check before this part goes on a BOM
Continuous conduction mode is the difference between this part and its eco-mode relatives. The TPS564208 does not skip cycles at light load, so the output stays at the same regulation point from no load to full load, at the cost of efficiency in the millamp range. On a rail that feeds a measurement circuit the constant frequency and the steady ripple are worth more than the light load efficiency.
Twenty two milliohms on the low side is low enough that the conduction loss at 4 A is about 0.35 W, and the high side adds about 0.1 W at a 12 V to 5 V conversion. With a junction limit of 125 C and a SOT-23 body, the copper under the part is the whole thermal answer, and a board that puts the part in a corner with a narrow pour will run hotter than the dissipation suggests.
The current limit maximum of 7.7 A is nearly twice the rated current. That matters when the inductor and the downstream device are chosen for a 4 A rail: the inductor saturation rating has to be above the maximum limit, not the typical one, or a hard fault drives the core into saturation before the part limits.
A 760 mV feedback threshold with 1.6 percent accuracy is tighter than the older 806 mV family. It also means the divider current is larger for the same output voltage, which is a small but real load on a standby rail. A 1 kOhm bottom resistor draws 0.76 mA, so a battery backed rail usually uses 10 kOhm or more and accepts the extra noise.
Start-up into a pre-biased output is a sequencing feature, not a protection. If the rail is held at 0.5 V by another supply when the enable rises, the part does not pull the output down before ramping it up, which keeps a device with two supply pins from seeing a reverse bias. Boards that sequence several rails should still verify the order in hardware rather than rely on the feature alone.
Fixed 560 kHz with no synchronisation is a constraint for a board with several converters. Two parts at slightly different frequencies beat against each other, and the beat lands at a low frequency that is difficult to filter. Where several rails share an input, the practical answer is to separate the input capacitors rather than to try to lock the clocks.
Hiccup on undervoltage and on overcurrent gives the part a restart behaviour without a supervisor. The cost is that a transient deep enough to trip the 65 percent threshold restarts the rail, so a load with a large inrush should be ramped by its own enable rather than by the converter soft start.
Where this order code fits
This order code belongs on 12 V to 5 V or 12 V to 1.8 V rails in set top boxes, access points, industrial gateways and display boards that need 4 A from a small footprint with no compensation network. The pre-bias start is what makes it usable on a rail that is held up by another supply during sequencing. Boards comparing it with a neighbouring part start from our Power Management Cross Reference page, and boards replacing a part that has gone end of life start from the How to Verify a Drop in Replacement page.
Questions buyers ask
Does the part skip cycles at light load? No. It runs in continuous conduction, which keeps the frequency and the ripple constant but costs efficiency in the millamp range.
What limits the output current? A cycle by cycle limit at 4.2 A minimum and 7.7 A maximum, followed by hiccup if the fault persists.
Can two of these share an input rail? Yes, but they are not synchronisable, so the input capacitors and the copper have to be laid out to keep the beat between the two frequencies out of sensitive circuits.
SUPERB quotes this order code against the tape and reel suffix with date codes, and the BOM Shortage Recovery page lists what to compare before a four amp socket is filled from another line.