Product Specifications

TPS563300DRLR — Power Management & Signal Chain | Superb Automation

TPS563300DRLR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS563300DRLR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS563300DRLR: 3 A synchronous buck converter that runs from a 28 V input in a 1.6 by 2.1 mm SOT

TPS563300DRLR is a 3 A synchronous step-down converter in the eight pin SOT583 body that accepts 3.8 V to 28 V, switches at 500 kHz with spread spectrum, holds 20 uA of quiescent current and reaches 98 percent duty for a supply that sags in a SOT583 body of 8 pins. The TPS563300 takes a 3.8 V to 28 V input and produces 0.8 V to 22 V at 3 A from an eight pin SOT583 measuring 1.6 mm by 2.1 mm. Peak current mode control with internal compensation and a fixed 500 kHz switching frequency carry the loop, and pulse frequency modulation at light load keeps the quiescent current at 20 uA. The reference is 0.8 V at plus or minus 1.5 percent at 25 C, and the junction range reaches 150 C.

Order code and package

Order codeTPS563300DRLR
Input voltage3.8 V to 28 V
Output voltage0.8 V to 22 V
Rated output current3 A continuous
Reference voltage0.8 V, plus or minus 1.5 percent at 25 C
Switching frequency450 kHz to 550 kHz, 500 kHz typical
Packageeight pin SOT583, 1.6 mm by 2.1 mm
Light load modepulse frequency modulation
Controlpeak current mode with internal compensation
DocumentSLUSES9, July 2022

Electrical parameters that decide the application

Non switching quiescent current20 uA typical
Shutdown current2 uA
Input UVLO, rising3.4 V to 3.8 V, 3.6 V typical
Input UVLO, falling3.1 V to 3.5 V, 3.3 V typical
High side switch resistance76 milliohm at a 5 V gate drive
Low side switch resistance32 milliohm
High side current limit4.2 A minimum, 5 A typical, 5.8 A maximum
Low side current limit2.9 A minimum, 3.8 A typical, 4.5 A maximum
Minimum peak inductor current0.75 A
Minimum on pulse width70 ns
Minimum off pulse width140 ns
Maximum on pulse width7 us
Maximum duty operation98 percent
Internal soft start2 ms
Output overvoltage trip115 percent typical, 5 percent hysteresis
Output undervoltage trip65 percent typical
Hiccup on time before restart256 us, restart after 10.5 soft start periods
Spread spectrumplus or minus 6 percent of the switching frequency
Thermal shutdown165 C with 30 C hysteresis
Thermal resistance, junction to ambient112.2 C per W on a JEDEC board
Junction temperature rangeminus 40 C to 150 C

Points to check before this part goes on a BOM

The 28 V input rating is the reason this part exists in a 1.6 by 2.1 mm body. Most converters that accept 28 V need a much larger package to hold the spacing, and this one keeps the switches at 76 and 32 milliohm in an eight pin SOT. The trade is thermal: 112.2 C per W on a JEDEC board means a 0.45 W loss is already a 50 C rise, and in an eight pin SOT the leads and the copper under them are the whole heat path.

Conduction loss at 3 A is 9 times 76 milliohm in the high side switch and 9 times 32 milliohm in the low side, which is 0.68 W and 0.29 W before duty is applied. A 24 V to 5 V rail runs at 21 percent duty, so the high side term is 0.14 W and the low side is 0.23 W, about 0.37 W in total, and the switching loss adds to that at 500 kHz. On the 112.2 C per W figure that is a 41 C rise before the ambient, which is why a 24 V to 5 V rail at 3 A is close to the practical limit in still air.

The 70 ns minimum on time and the 140 ns minimum off time together define the reachable duty range at 500 kHz. The period is 2 us, so the minimum on time is 3.5 percent and the minimum off time is 7 percent, which caps the fixed frequency duty at 93 percent. The 98 percent maximum duty figure is reached by extending the on pulse up to 7 us, which lowers the frequency for the duration of the event. That is how a 5 V output survives a 5.1 V input, and it is also why the switching spectrum moves during a supply dip.

Spread spectrum at plus or minus 6 percent around 500 kHz is an emissions tool rather than a performance one. It moves the switching energy across a 60 kHz band at a modulation rate of the switching frequency divided by 128, which is about 3.9 kHz, so a receiver measuring at 500 kHz sees the energy spread instead of concentrated. The cost is a small ripple in the output at the modulation rate, which matters on an analogue rail and does not on a digital one.

Current limit comes in two levels: 4.2 A to 5.8 A on the high side and 2.9 A to 4.5 A on the low side, and the minimum peak inductor current of 0.75 A is the floor below which the converter will not regulate in pulse frequency mode. A 3 A rail sits 600 mA below the minimum low side limit, so an overload of 20 percent is inside the limit and an overload of 50 percent is not. The valley limit acts on the bottom of the ripple, which means the trip point moves with the inductor value: a larger inductor lowers the ripple and lets more DC current through before the valley reaches the threshold.

Undervoltage protection is a hiccup rather than a latch. The trip is at 65 percent of the reference, the converter stays off for 256 us and then restarts after 10.5 soft start periods, which at a 2 ms soft start is 21 ms. A shorted output therefore sees a low duty retry rather than a continuous 5 A, and the average dissipation stays low enough that an eight pin SOT survives until the fault is cleared. The overvoltage side is separate, at 115 percent with 5 percent of hysteresis, and it does not restart the converter.

The input undervoltage lockout at 3.6 V rising and 3.3 V falling, with 300 mV of hysteresis, sets the lowest usable input and explains the 3.8 V minimum in the title. A 5 V rail at minus 10 percent is 4.5 V, comfortably above the threshold, while a 3.3 V rail is below it and cannot start the part at all. The enable pin has its own 1.28 V threshold with a 0.7 uA pull-up, so a divider can set a precise turn on point above the lockout.

Where this order code fits

This order code belongs on 24 V industrial buses, 12 V and 18 V rails in instrumentation, motor control housekeeping supplies, building automation nodes and any board that has to survive a 28 V transient while producing 3 A at 5 V or 3.3 V. It is the part chosen when the input can be a loosely regulated bus and the converter has to hold regulation through a dip rather than drop out. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Component Lead Time Solutions page.

Questions buyers ask

Can this part run from a 24 V bus at 3 A continuously? It can, and the thermal margin is thin. A 24 V to 5 V conversion at 3 A dissipates about 0.37 W in the switches plus the switching term, which is a 41 C rise on the JEDEC figure. In a 60 C enclosure that leaves the junction near 101 C against a 150 C limit, so the rail works and it has less margin than the numbers suggest. A 24 V to 3.3 V rail carries more duty at the low side switch and runs hotter.

What does the 98 percent duty figure mean in practice? It means a 5 V output can hold regulation from an input that has fallen to about 5.1 V, which is what a 5 V bus at minus 5 percent looks like during a load step. The converter reaches it by stretching the on pulse up to 7 us and letting the frequency fall, so the rail survives the dip at the cost of a switching spectrum that moves for the duration.

Why does the current limit depend on the inductor? The low side limit is a valley threshold, so it acts on the lowest point of the ripple. A larger inductor produces less ripple, which lifts the average current at which the valley reaches the threshold. A 3 A rail built with a small inductor can therefore trip earlier than the same rail with a larger one, and the 0.75 A minimum peak current is the floor that keeps the valley measurement meaningful.

Is 20 uA of quiescent current maintained in all modes? It is the non switching figure with the enable high, which is the state the converter sits in when the load is light enough for pulse frequency modulation to stop switching. In continuous conduction the supply current is set by the gate drive and the switching, which is far higher. A product that quotes 20 uA in its standby specification is describing the light load state, not a 3 A rail.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the BOM Shortage Recovery page sets out the checks that keep a substitute from failing on the bench.